Use the following table to interpret the LED status on the EPDB (503-00682C) used in all Trendsetter series 5 devices.

LED Status Alert status On alert status check the following:

Green (on) = REG5-1=3.3V, REG5-4=1.22V (R157, RR67 and the


LED1 Green (off) = 1.8V FAIL
1.8V OK REG5 peripherals components), REG5-5=1.8V

REG3-2=5V, REG3-1=5V, REG3-4=1.216V (R149,


Green (on) =
LED2 Green (off) = VCC3 FAIL RR161, RR162 and the REG3 peripherals components),
VCC3 OK
REG3-3=3.3V

Green (on) = P12V REG1-6=24V, REG1-8=24V, REG1-1=12V (R133, R131,


LED3 Green (off) = P12V FAIL
OK R132 and the REG1 peripherals components)

Green (on) = Green (off) = P24V_SW Q19-3=24V, Q19-1=12V, Q19-2= Not shorted to
LED4
P24V_SW OK FAIL PWRGND and the Q19 peripherals components

TP_P12V=12V if no, then see action check for LED3,


Green (on) = P48V
LED5 Green (off) = P48V FAIL Q17-1=12V, REG2=12V, D8-2 Not shorted to PWRGND
OK
and the REG peripherals components

Green (on) = P24V


LED6 Green (off) = P24V FAIL J1-7..11=24V
OK

Yellow (on) = Yellow (off) =


LED7 Focus laseroverride Focus laseroverride No action required; status indication only
mode selected mode NOT selected

Yellow (on) = SIO


Yellow (off) = SIO override
LED8 override mode No action required; status indication only
mode NOT selected
selected

Yellow (blinking) =
Yellow (off) = SPI
LED9 SPI communication No action required; status indication only
communication inactive
active

When Red (on) check the following:

Red (on) = device requires Emergency stop loop


hard reset (cycle power) Periodic test fail
LED10
Red (off) = OK
[CPLD1] Red (blinking) = device Unsymmetrical interlock door loop
requires soft reset (initialize)
RLY1 24V/48V SAFE failure
(See Error code 49220)

Green (blinking) =
Green (off) = no code is
LED11 FW code is loaded
loaded
on board

Red (on) = component fault


LED12 Red (off) = OK Replace the board.
has occurred on board

LED13 Red (off) = OK Red (on) = The board Replace the board.
hardware components and
firmware code not meet
the safety requirements.

https://services.kodak.com/app/answers/detail/a_id/72479/kw/Laser safety looP 1/2


6/13/2020 EOS Power Distribution Board (EPDB) led status description for Trendsetter Series V (Model TEE) platesetters

Yellow (on) = Hall


Sensor A from Yellow (off) = Hall Sensor A
LED14 No action required; status indication only
drum motor is from drum motor is inactive
active

Yellow (on) = Hall


Sensor B from Yellow (off) = Hall Sensor B
LED15 No action required; status indication only
drum motor is from drum motor is inactive
active

Yellow (on) = Hall


Sensor C from Yellow (off) = Hall Sensor C
LED16 No action required; status indication only
drum motor is from drum motor is inactive
active

Usually this indicates that the safety loop (a panel) is


Green (on) = Green (off) = P24V_SAFE open; however, it can also be OFF during a fault such as
LED17
P24V_SAFE OK OFF Overcurrent or a P24V fault. Check DET23, DET52,
DET54, DET47, DET19.

Usually this indicates that the safety loop (a panel) is


Green (on) = Green (off) = P48V_SAFE open; however, it can also be OFF during a fault such as
LED18
P48V_SAFE OK OFF Overcurrent or a P48V fault. Check DET52, DET54,
DET47, DET19, DET20.

Blue (on) =
Main AC line power Blue (off) = Main AC line
LED19 (Phase L1, L2) power (Phase L1, L2) is NOT No action required; status indication only
is detected on detected on board
board

https://services.kodak.com/app/answers/detail/a_id/72479/kw/Laser safety looP 2/2