Professional Documents
Culture Documents
Use the following table to interpret the LED status on the EPDB (503-00682C) used in all Trendsetter series 5 devices.
Green (on) = Green (off) = P24V_SW Q19-3=24V, Q19-1=12V, Q19-2= Not shorted to
LED4
P24V_SW OK FAIL PWRGND and the Q19 peripherals components
Yellow (blinking) =
Yellow (off) = SPI
LED9 SPI communication No action required; status indication only
communication inactive
active
Green (blinking) =
Green (off) = no code is
LED11 FW code is loaded
loaded
on board
LED13 Red (off) = OK Red (on) = The board Replace the board.
hardware components and
firmware code not meet
the safety requirements.
Blue (on) =
Main AC line power Blue (off) = Main AC line
LED19 (Phase L1, L2) power (Phase L1, L2) is NOT No action required; status indication only
is detected on detected on board
board