Professional Documents
Culture Documents
Summary
The Arc Rating of this material is intended for use as part of a flame resistant garment or system for workers exposed to electric arcs. The test
result is applicable only to the test item as described; other fiber blends, weaves, finishing or dye may have different protection level. The test
articles are tested as received; no test is done to validate the fiber content or composition. The Arc Rating was calculated based on the data
obtained and analysed in accordance with the latest version of the applicable standards. The individual test sheets, graphs, photographs of the
samples and video of every test are provided in digital format to the Client for review.
The arc testing performed to the above mentioned Standard is accredited by the Standards Council of Canada (SCC) to conform to the
requirements of CAN-P-4E (ISO/IEC 17025:2005). Accreditation by the Standards Council of Canada (SCC) is a mark of competence and reliability
recognized throughout the world.
Kinectrics Inc takes reasonable steps to ensure that all work performed shall meet the industry standards as set out in Kinectrics Inc.'s Quality
Manual, and that all reports shall be reasonably free of errors, inaccuracies or omissions. KINECTRICS INC. DOES NOT MAKE ANY WARRANTY
OR REPRESENTATION WHATSOEVER, EXPRESS OR IMPLIED, WITH RESPECT TO THE MERCHANTABILITY OR FITNESS FOR ANY
PARTICULAR PURPOSE OF ANY INFORMATION CONTAINED IN THIS REPORT OR THE RESPECTIVE WORKS OR SERVICES SUPPLIED OR
PERFORMED BY KINECTRICS INC. Kinectrics Inc. does not accept any liability for any damages, either directly, consequentially or otherwise
resulting from the use of this report.
Note: The test performed does not apply to electrical contact or electrical shock hazard.
©Kinectrics. Partial reproduction of this report is strictly prohibited without the express written consent of Kinectrics Inc.
Note: For verification about results in this report, please forward copy of the report or inquiry to hcl@kinectrics.com
Page 1 of 3
Date: Determination of ATPV by performing logistic regression on the panel
Jul-14-15 burn response as indicated in Summary Table
Report # Test Performed in accordance with: ASTM F2178-12
K-418806-1506F01-R00
Fabric Description:
BSD GmbH, Faceshield and Balaclava,
BSD ErgoS Power, Article No. 74064xx,
Lens: BSD 50 Special Polycarbonate Lens, Grey-Special, Thickness 1.5mm,
Hard Hat: Voss, Model Elektrikerhelm,
Balaclava Fabric: 2 Layers of BSD, Style Novotex, 265 g/m² Knit, 50% Kermel 50% Viscose, Dark Blue,
ArcWear# 1506F01
Probability Ei
90
5% 21.2
80 10% 22.4
20% 23.6
70 30% 24.4
40% 25.0
60 50% 25.6
60% 26.3
50
70% 26.9
40 80% 27.7
90% 28.9
30 (Note: ATPV is reported to nearest integer
for ratings above 10 cal/cm²)
20
Total points analyzed = 20
Points above Stoll = 9
10
Points above mix zone = 5
Points below mix zone = 7
0 # Pts within 20% = 17
19 20 21 22 23 24 25 26 27 28 29 30 31 # Pts in mix zone = 8
Incident Energy (cal/cm²)
Determination of HAF
100
HAF = 93 %
95 Confidence Intervals
95% CI = 92.1 , 93.9
90
85
80
75
Data pts
70
Best Fit
65
95% CI
60
95% CI pts
55
50
19 20 21 22 23 24 25 26 27 28 29 30 31
Incident Energy (cal/cm²)
Page 2 of 3
Date: Summary of Measured Energy and Observations
Jul-14-15
Test Performed in accordance with : ASTM F2178-12
Report #
K-418806-1506F01-R00
1 K-418806-4656 A 7951 36.2 27.1 1.9 87.0 Yes - - - No Burns on both eyes and mouth.
2 K-418806-4656 B 7951 36.2 30.7 0.4 93.4 Yes - - - No Burn on mouth only.
3 K-418806-4657 A 7888 30.7 24.3 0.5 91.2 Yes - - - No Burns on both eyes and mouth.
4 K-418806-4657 B 7888 30.7 28.0 0.1 94.0 Yes - - - No Burn on mouth only.
5 K-418806-4658 A 8003 25.2 19.6 -0.1 93.0 No - - - No
6 K-418806-4658 B 8003 25.2 20.2 -0.3 94.1 No - - - No
7 K-418806-4659 A 7970 27.3 24.0 -0.3 94.8 No - - - No
8 K-418806-4659 B 7970 27.3 22.2 -0.6 95.6 No - - - No
9 K-418806-4660 A 7978 28.7 21.6 -0.3 94.2 No - - - No
10 K-418806-4660 B 7978 28.7 19.7 -0.7 95.9 No - - - No
11 K-418806-4661 A 7954 32.2 24.2 0.3 92.2 Yes - - - No Burn on mouth only.
12 K-418806-4661 B 7954 32.2 23.6 -0.3 94.4 No - - - No
13 K-418806-4663 A 7938 34.1 30.6 1.2 90.4 Yes - - - No Buerns on both eyes and mouth.
14 K-418806-4663 B 7938 34.1 27.5 -0.4 95.4 No - - - No
15 K-418806-4664 A 7878 33.2 29.5 0.6 92.2 Yes - - - No Burns on right eye and mouth.
16 K-418806-4664 B 7878 33.2 24.2 -0.6 95.7 No - - - No
17 K-418806-4665 A 7938 33.7 25.0 0.8 90.1 Yes - - - No Burns on both eyes and mouth.
18 K-418806-4665 B 7938 33.7 26.0 -0.1 93.9 No - - - No
19 K-418806-4666 A 7940 34.7 29.4 0.5 92.3 Yes - - - No Burns on both eyes and mouth.
20 K-418806-4666 B 7940 34.7 25.2 -0.2 94.3 No - - - No
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
No evidence of afterflame, melting, dripping or ignition of any system component during testing.
Page 3 of 3