You are on page 1of 6

Employer Building at Hemmigepura Doc No:

BWSSB BWSSPIII/27/COM/EPO/CV/DC/7017

Combined Footing-CF1 Rev No: 0

DESIGN OF COMBINED FOOTING : CF1


INPUT LOAD CASE = 113 Mx(KN-m) My(KN-m) AXIAL LOAD(KN)

UNFACTORED LOAD ON COLUMN-1 IN T (P1) = JNT 6 1.000 -152.000 863.000


UNFACTORED LOAD ON COLUMN-2 IN T (P2) = JNT 7 -156.000 -4.000 853.000
LENGTH OF COLUMN-1 IN M (l1) = 0.230
WIDTH OF COLUMN-1 IN M (b1) = -155.000 -156.000 0.675
LENGTH OF COLUMN-2 IN M (l2) = 0.600
WIDTH OF COLUMN-2 IN M (b2) = 0.300
BEARING PRESSURE IN KN/M2 = 125.000
CONCRETE GRADE IN N/MM2 (sck) = 25.000
STEEL GRADE IN N/MM2 (sy) = 500.000
DISTANCE BETWEEN COLUMN- & COLUMN-2 IN M (Y) = 2.030

P1 P1+P2 P2

X= 1.009 X'= 1.021

X1= 1.516 Y= 2.030 X2= 1.504

1.973 2.146
L 5.050
1.788

1.975

1.401 0.230 0.600 1.204


0.675
4.250

0.300

B1
1.788

1.975

D= 400.000

LENGTH AND WIDTH OF FOOTING

LOCATION OF CG FROM CL COLUMN-1 (X) (M) 1.009


LOCATION OF CG FROM CL COLUMN-2 (X') (M) 1.021
TOTAL LOAD (KN) 1716.000

TOTAL LOAD (KN) 1716.000


SIZE OF FOOTING REQUIRED (M2) 13.728
ASSUME WIDTH OF FOOTING {B} (M) 4.250
LENGTH REQUIRED (M) 3.230
LENGTH PROVIDED {L} (M) 5.050
UPWARD Px 69.758
UPWARD Py 71.318
PROJECTION ON LEFT SIDE FROM CL OF COLUMN-1 {X1} (M) 1.516
PROJECTION ON RIGHT SIDE FROM CL OF COLUMN-2 {X1'} (M) 1.504
Employer Building at Hemmigepura Doc No:
BWSSB BWSSPIII/27/COM/EPO/CV/DC/7017

Combined Footing-CF1 Rev No: 0


LONGITUDINAL BENDING MOMENT AND SHEAR

FACTORED LOAD ON COLUMN-1 (KN) 1294.500


FACTORED LOAD ON COLUMN-2 (KN) 1279.500

ACTUAL FACTORED UPWARD PRESSURE (KN/M2) Py 106.976


ACTUAL FACTORED UPWARD PRESSURE PER UNIT LENGTH (KN/M) 454.650
NET FACTORED UPWARD PR. 106.976 - 0.000 X 4.250 454.650
SHEAR FORCE AT CL OF COLUMN-1 FROM LEFT SIDE (KN) -689.210 0.000
SHEAR FORCE AT CL OF COLUMN-1 FROM RIGHT SIDE (KN) 605.290

SHEAR FORCE AT CL OF COLUMN-2 FROM RIGHT SIDE (KN) 683.832


SHEAR FORCE AT CL OF COLUMN-2 FROM LEFT SIDE (KN) -595.668

POINT OF ZERO SHEAR FROM CG OF COLUMN-1 (M) 1.023


POINT OF ZERO SHEAR FROM CG OF COLUMN-2 (M) 1.007

MAXIMUM BM COMPUTED FROM LEFT SIDE (KN-M) at top 141.064


MAXIMUM BM COMPUTED FROM RIGHT SIDE (KN-M) at top 144.969

BM = 0.138 * sck * b * d2

PROVIDE TOTAL DEPTH (MM) 400.000


EFFECTIVE DEPTH PROVIDED (MM) 342.000

LONGITUDINAL POSITIVE REINFORCEMENT (BOTTOM REINF.)

BM AT FACE OF COLUMN-1 (KN-TM) 446.139


AREA OF STEEL REQUIRED (MM2) 3134.000
MINIMUM Ast @ 0.12% (MM2) 2040.000
REQUIRED Ast FOR BENDING (MM2) 3134.000

REQUIRED 10 dia Nos. 39.92 or 12 dia Nos. 27.73


16 dia Nos. 15.51 or 20 dia Nos. 9.98
PROVIDE 16 20 Nos. 4040.000
16 221 c/c
% OF STEEL PROVIDED = 0.278

BM AT FACE OF COLUMN- 2 (TM) 329.580


AREA OF STEEL REQUIRED (MM2) 2287.359
MINIMUM Ast @ 0.12% (MM2) 2040.000
REQUIRED Ast FOR BENDING (MM2) 2287.359

REQUIRED 10 dia Nos. 29.14 or 12 dia Nos. 20.24


16 dia Nos. 11.32 or 20 dia Nos. 7.28
PROVIDE 16 20.0 Nos. 4040.000
16 221 c/c
Pt in % PROVIDED = 0.278
Employer Building at Hemmigepura Doc No:
BWSSB BWSSPIII/27/COM/EPO/CV/DC/7017

Combined Footing-CF1 Rev No: 0

SHEAR ONE WAY ACTION

SHEAR FORCE AT A DISTANCE 'd' FROM RIGHT FACE OF COLUMN-1 (KN) ABS VALUE 397.515
SHEAR FORCE AT A DISTANCE 'd' FROM LEFT FACE OF COLUMN-1 (KN) 481.435
ACTUAL SHEAR STRESS (N/MM2) = 0.331

% OF STEEL PROVIDED = 0.278


DESIGN SHEAR STRENGTH OF CONCRETE tc (N/MM2) = 0.382

SHEAR TWO WAY ACTION

VERT. FORCE AT A DISTANCE 'd/2' FROM FACE OF COLUMN-1 (KN) 1258.209


ACTUAL SHEAR STRESS (N/MM2) = 1.158
DESIGN SHEAR STRENGTH OF CONCRETE t'c = kstc (N/MM2) 1.250
ks=(0.5+bc) but <1 1.000
bc=(LENGTH OF COLUMN/WIDTH OF COLUMN) 2.935
tc =0.25*SQRT(sck) 1.250

SHEAR FORCE AT A DISTANCE 'd/2' FROM FACE OF COLUMN-2 (kn) 1240.652


INDUCED PUNCHING SHEAR STRESS (N/MM2) = 1.145
DESIGN SHEAR STRENGTH OF CONCRETE t'c = kstc (N/MM2) 1.250
ks=(0.5+bc) but <1 1.000
bc=(LENGTH OF COLUMN/WIDTH OF COLUMN) 2.000
tc =0.25*SQRT(sck) 1.250

TRANSVERSE REINFORCEMENT (BOTTOM)

FACTORED UPWARD PRESSURE UNDER COLUMN-1 (kn/MM2)(NET PRESSURE) 104.637


BM AT FACE OF COLUMN-1 (kn-M) 167.165
AREA OF STEEL REQUIRED (MM2) 1456.363

REQUIRED 10 dia 53.90 or 12 dia . 77.59


16 dia . 138.7 or 20 dia. 215.61

PROVIDE 16 125 c/c

FACTORED UPWARD PRESSURE UNDER COLUMN-2 (kn/MM2) 104.637


BM AT FACE OF COLUMN-2 (KNM) 204.074
AREA OF STEEL REQUIRED (MM2) 1456.363

REQUIRED 10 dia 53.90 or 12 dia 77.59


16 dia 138.7 or 20 dia 215.61

PROVIDE 16 125 c/c


Employer Building at Hemmigepura Doc No:
BWSSB BWSSPIII/27/COM/EPO/CV/DC/7017

Combined Footing-CF1 Rev No: 0

DESIGN OF COMBINED FOOTING : CF1


INPUT LOAD CASE = 113 Mx(KN-m) My(KN-m) AXIAL LOAD(KN)

UNFACTORED LOAD ON COLUMN-1 IN T (P1) = JNT 6 147.000 4.000 674.000


UNFACTORED LOAD ON COLUMN-2 IN T (P2) = JNT 7 -103.000 6.000 704.000
LENGTH OF COLUMN-1 IN M (l1) = 0.675
WIDTH OF COLUMN-1 IN M (b1) = 44.000 10.000 0.230
LENGTH OF COLUMN-2 IN M (l2) = 0.600
WIDTH OF COLUMN-2 IN M (b2) = 0.230
BEARING PRESSURE IN KN/M2 = 125.000
CONCRETE GRADE IN N/MM2 (sck) = 25.000
STEEL GRADE IN N/MM2 (sy) = 500.000
DISTANCE BETWEEN COLUMN- & COLUMN-2 IN M (Y) = 2.030

P1 P1+P2 P2

X= 1.037 X'= 0.993

X1= 1.413 Y= 2.030 X2= 1.457

2.042 2.049
L 4.900
1.210

1.210

1.075 0.675 0.600 1.157


0.230
2.650

0.230

B1
1.210

1.210

D= 350.000

LENGTH AND WIDTH OF FOOTING

LOCATION OF CG FROM CL COLUMN-1 (X) (M) 1.037


LOCATION OF CG FROM CL COLUMN-2 (X') (M) 0.993
TOTAL LOAD (KN) 1378.000

TOTAL LOAD (KN) 1378.000


SIZE OF FOOTING REQUIRED (M2) 11.024
ASSUME WIDTH OF FOOTING {B} (M) 2.650
LENGTH REQUIRED (M) 4.160
LENGTH PROVIDED {L} (M) 4.900
UPWARD Px 113.795
UPWARD Py 107.065
PROJECTION ON LEFT SIDE FROM CL OF COLUMN-1 {X1} (M) 1.413
PROJECTION ON RIGHT SIDE FROM CL OF COLUMN-2 {X1'} (M) 1.457
Employer Building at Hemmigepura Doc No:
BWSSB BWSSPIII/27/COM/EPO/CV/DC/7017

Combined Footing-CF1 Rev No: 0


LONGITUDINAL BENDING MOMENT AND SHEAR

FACTORED LOAD ON COLUMN-1 (KN) 1011.000


FACTORED LOAD ON COLUMN-2 (KN) 1056.000

ACTUAL FACTORED UPWARD PRESSURE (KN/M2) Py 160.598


ACTUAL FACTORED UPWARD PRESSURE PER UNIT LENGTH (KN/M) 425.585
NET FACTORED UPWARD PR. 160.598 - 0.000 X 2.650 425.585
SHEAR FORCE AT CL OF COLUMN-1 FROM LEFT SIDE (KN) -601.310 0.000
SHEAR FORCE AT CL OF COLUMN-1 FROM RIGHT SIDE (KN) 409.690

SHEAR FORCE AT CL OF COLUMN-2 FROM RIGHT SIDE (KN) 620.119


SHEAR FORCE AT CL OF COLUMN-2 FROM LEFT SIDE (KN) -435.881

POINT OF ZERO SHEAR FROM CG OF COLUMN-1 (M) 0.984


POINT OF ZERO SHEAR FROM CG OF COLUMN-2 (M) 1.046

MAXIMUM BM COMPUTED FROM LEFT SIDE (KN-M) at top 227.696


MAXIMUM BM COMPUTED FROM RIGHT SIDE (KN-M) at top 228.679

BM = 0.138 * sck * b * d2

PROVIDE TOTAL DEPTH (MM) 350.000


EFFECTIVE DEPTH PROVIDED (MM) 292.000

LONGITUDINAL POSITIVE REINFORCEMENT (BOTTOM REINF.)

BM AT FACE OF COLUMN-1 (KN-TM) 246.093


AREA OF STEEL REQUIRED (MM2) 2045.585
MINIMUM Ast @ 0.12% (MM2) 1113.000
REQUIRED Ast FOR BENDING (MM2) 2045.585

REQUIRED 10 dia Nos. 26.06 or 12 dia Nos. 18.10


16 dia Nos. 10.13 or 20 dia Nos. 6.51
PROVIDE 12 20 Nos. 2260.000
12 137 c/c
% OF STEEL PROVIDED = 0.292

BM AT FACE OF COLUMN- 2 (TM) 284.902


AREA OF STEEL REQUIRED (MM2) 2390.697
MINIMUM Ast @ 0.12% (MM2) 1113.000
REQUIRED Ast FOR BENDING (MM2) 2390.697

REQUIRED 10 dia Nos. 30.45 or 12 dia Nos. 21.16


16 dia Nos. 11.84 or 20 dia Nos. 7.61
PROVIDE 12 21.5 Nos. 2429.500
12 127 c/c
Pt in % PROVIDED = 0.314
Employer Building at Hemmigepura Doc No:
BWSSB BWSSPIII/27/COM/EPO/CV/DC/7017

Combined Footing-CF1 Rev No: 0

SHEAR ONE WAY ACTION

SHEAR FORCE AT A DISTANCE 'd' FROM RIGHT FACE OF COLUMN-1 (KN) ABS VALUE 141.784
SHEAR FORCE AT A DISTANCE 'd' FROM LEFT FACE OF COLUMN-1 (KN) 333.405
ACTUAL SHEAR STRESS (N/MM2) = 0.431

% OF STEEL PROVIDED = 0.292


DESIGN SHEAR STRENGTH OF CONCRETE tc (N/MM2) = 0.390

SHEAR TWO WAY ACTION

VERT. FORCE AT A DISTANCE 'd/2' FROM FACE OF COLUMN-1 (KN) 961.424


ACTUAL SHEAR STRESS (N/MM2) = 1.106
DESIGN SHEAR STRENGTH OF CONCRETE t'c = kstc (N/MM2) 1.250
ks=(0.5+bc) but <1 1.000
bc=(LENGTH OF COLUMN/WIDTH OF COLUMN) 2.935
tc =0.25*SQRT(sck) 1.250

SHEAR FORCE AT A DISTANCE 'd/2' FROM FACE OF COLUMN-2 (kn) 1010.953


INDUCED PUNCHING SHEAR STRESS (N/MM2) = 1.224
DESIGN SHEAR STRENGTH OF CONCRETE t'c = kstc (N/MM2) 1.250
ks=(0.5+bc) but <1 1.000
bc=(LENGTH OF COLUMN/WIDTH OF COLUMN) 2.609
tc =0.25*SQRT(sck) 1.250

TRANSVERSE REINFORCEMENT (BOTTOM)

FACTORED UPWARD PRESSURE UNDER COLUMN-1 (kn/MM2)(NET PRESSURE) 170.692


BM AT FACE OF COLUMN-1 (kn-M) 124.955
AREA OF STEEL REQUIRED (MM2) 1060.821
1060.821
REQUIRED 10 dia 74.00 or 12 dia . 106.52
16 dia . 190.4 or 20 dia. 296.00

PROVIDE 12 100 c/c

FACTORED UPWARD PRESSURE UNDER COLUMN-2 (kn/MM2) 170.692


BM AT FACE OF COLUMN-2 (KNM) 124.955
AREA OF STEEL REQUIRED (MM2) 1060.821
1060.821
REQUIRED 10 dia 74.00 or 12 dia 106.52
16 dia 190.4 or 20 dia 296.00

PROVIDE 12 100 c/c

You might also like