Summary Observation on Slag & Clinker before & after Thermact dosing in Unit # 50
From 20th Sept till 1st Nov 16
Observations during Thermact Dosing from 29th Sept till 19th Oct:
On 29th Sep 2016, the clinker formation was observed at centre of Goose neck
Slope panel at 63.3 Mtr. Boiler elevations. Which can be seen from the Photographs
record taken from Peep Holes near 175 & 176 soot blowers at 63.3 M Elevation of
Boiler?
As per CGPL official Instruction, Thermact Dosing was started on 30 th Sep 2016 in
1:30 dosing ratio.
After start of Thermact dosing from our daily observations , gradual reduction in
Slag deposite was observed at Gooseneck centre & more no. of tubes were visible
in Slope panel as well as in between the RH panel and slope panel. Same can be
seen from the Photos taken on 19.10.2016.
Observation Report after stopping Thermact usage 21-oct-2016 till 1 st Nov 2016.
We have included the photos which we have taken during past few days(without
Thermact usage ) of Goose neck area , divisional panel and Water wall.
Observations during Thermact Dosing from 29th Sept till 19th Oct:
On 29th Sep 2016, the clinker formation was observed at centre of Goose neck
Slope panel at 63.3 Mtr. Boiler elevations. Which can be seen from the
Photographs record taken from Peep Holes near 175 & 176 soot blowers at 63.3
M Elevation of Boiler?
As per CGPL official Instruction, Thermact Dosing was started on 30 th Sep 2016
in 1:30 dosing ratio.
After start of Thermact dosing from our daily observations , gradual reduction
in Slag deposite was observed at Gooseneck centre & more no. of tubes were
visible in Slope panel as well as in between the RH panel and slope panel.
Same can be seen from the Photos taken on 19.10.2016.
Before Thermact (29th Sep 16) After Thermact (19th Oct 16)
Before Thermact (29th Sep 16) After Thermact (19th Oct 16)
Div. Panel SH Windows
Before Thermact (29th Sep 16) After Thermact (19th Oct 16)
Window 1 Window1
Window 2 Window 2
Window 3 Window 3
Div. Panel SH Windows
Before Thermact (29th Sep 16) After Thermact (19th Oct 16)
Window 4 Window 4
Window 5 Window 5
Window 6 Window6
Div. Panel SH Windows
Before Thermact (29th Sep 16) After Thermact (19th Oct 16)
Window 7 Window 7
Window 8 Window 8
Window 9 Window 9
Observation Report without Thermact in Unit #50 dated 21-
oct-2016 to 23-oct-2016.
Without Thermact (25th Oct 16) Without Thermact (27th Oct 16)
Observation on Slag & Clinker in Unit # 50 on 1st November’16
As shown above Clinker formation had reduced after 20 days of Thermact Dosing
from 30th September’16 to 20th Oct 16.
Thermact Dosing Had stopped on 20th October’16 at 11.00 hrs.
After 3 days of stoppage of Thermact dosing, the continuous increase in the
Clinker size was observed on Goose Neck area, Super heater tubes & Reheater
Panel.
Divisional window panels also observed high amount slagging.
On 1st Nov after 10 days of discontinues, we observed big clinker on Gooseneck,
slagging & clinker formation on water wall region. The Photos have been displayed
below:
Window 3 Window 4
Window 5 Window 6
Window 7 Window 8
WINDOW 9
OBSERVATION OF SLAGGING & CLINKER ON WATER WALL REGION
At Elevation 55 Mtrs, Slagging & Clinker was found on all the Corners of AB Side,
BC Side, CD Side, AD Side.
Photos had been taken on 29th October’16.
High Amount of Clinker and Slagging is observed on water wall region.
At Elevation 50 Mtrs, Slagging & Clinker was found on all the Corners of AB Side,
BC Side, CD Side, AD Side.
Photos had been taken on 29th October’16.
At Elevation 46 Mtrs, Slagging & Clinker was found on all the Corners of AB Side,
BC Side, CD Side, AD Side.
Photos had been taken on 29th October’16.
At Elevation 43 Mtrs, Slagging & Clinker was found on all the Corners of AB Side,
BC Side, CD Side, AD Side.
Photos had been taken on 29th October’16.
AB Side Near Wall Blower 78 BC Side Near Wall Blower 84
At Elevation 40 Mtrs, Slagging & Clinker was found on all the Corners of AB Side,
BC Side, CD Side, AD Side.
Photos had been taken on 29th October’16.
AB Side Near Wall Blower 50 BC Side Near Wall Blower 30