Document Title: Function Group: Information Type: Date:


Tool, removing 926 Service Information 2/27/2018
Profile:
HB70

Tool, removing
Showing Selected Profile

Valid for serial numbers


Model Production site Serial number start Serial number stop
HB70

Op nbr 926-004

Total procedure time (hr): 0.30

1. Place the hydraulic breaker on the floor and make sure that the holes for the tool retaining pins can be accessed (over
the edge of the pallet).
NOTE!
Never use your fingers to check if the recesses on the work tool's shaft are aligned with the slots for the tool pin.

NOTE!
Always wear protective goggles when installing or removing the tool, since metal splinters may fly off when breaking
out the stopper pins.

2. Remove plugs.

Figure 1
Plugs, removing

1. Plugs

3. Remove the plug.


Remove the lock pin with punch and hammer.

WARNING
The parts are hot, take appropriate safety precautions.
Figure 2
Plug and lock pin, removing

1. Plug
2. Lock pin
3. Punch
4. Hammer

4. Install the eye bolt.

Figure 3
Eye bolt, installing

1. Eye bolt

5. Hold the retaining pins and remove the lock pin.

Figure 4
Lock pin and retaining pins, removing

1. Retaining pin
2. Plug
3. Lock pin
4. Punch
5. Hammer

6. Remove the tool with a hoist.

Figure 5
Tool, removing

1. Hoist

You might also like