• midas Gen
1) Add column design by constant P 4

2)  Insert strength loss option for EC8 hinge type 5

3) Improvement about masonry pushover analysis and post processing  6
4) Energy result graph & additional damping ratio in time‐history analysis results  11
5) Add reaction table for each step in pushover 14
6) Select Inelastic Hinge Result Output in Inelastic time history analysis  15
7) Improvement in analysis speed for inelastic time history analysis 17
8) Add result summary table of fiber beam, wall for inelastic hinge  18
9) Revit 2020 interface 19
10) Non‐dissipative element design for slab as per NTC2018  20
11) Improvement of slab design as per EC2 and NTC 21
12) Improvement of non‐dissipative design 22
13) Improvement of inelastic material model 23

14) Improvement of joint design as per EC2 and NTC 24
15) Cyclic shear resistance check as per EN1998‐3:2005 & NTC2018  27
16) Improvement of hinge model as per EC 29

• midas Design+
1) Steel  design tool as per AISC 31
2) Anchor bolt module as per ACI 37
midas Gen Gen 2020 v2.1 Release Note

1. Improvement of Column Design

Column Design by Constant P

Setting of Concrete Design Code

Keep M/P Constant Keep Constant P (New)

Add Option
• Support seismic design by axial force(P) constant method.
• Apply axial force(P) constant method to all or individual columns

4 /39
midas Gen Gen 2020 v2.1 Release Note

2. Insert strength loss option for EC8 hinge type

Insert Strength loss option for EC8 hinge type

5 /39
midas Gen Gen 2020 v2.1 Release Note

3. Improvement about masonry pushover analysis and post processing

Improvement about Masonry pushover analysis and post processing


• Printout “q*” value in Text Output

6 /39
midas Gen Gen 2020 v2.1 Release Note

3. Improvement about masonry pushover analysis and post processing

Calculation for Target Displacement in Masonry as per NTC 2018

SLO
Displacement of limit elastic dSLD x 2/3

SLD
Capacity of SLD
= Min.Displacement of Ve and ¾ Vu

*Ve = max shear of bilinear


*Vu = max shear of MDOF curve

SLV
Last displacement of bilinear x 3/4

Output Remark for SLV & SLC


SLC
Last displacement of bilinear * gamma

Ve Vu

7 /39
midas Gen Gen 2020 v2.1 Release Note

3. Improvement about masonry pushover analysis and post processing

Updating ‘My’ in Masonry with Pier hinge Type

• Add a building type. Building type had ‘New Buildings’ and ‘Existing Buildings’
• Set a default value of D/H according to the building type

Default Values of D/H


New Existing
Point
Building Building

C 0.01 0.01

D 0.01 0.01

8 /39
midas Gen Gen 2020 v2.1 Release Note

3. Improvement about masonry pushover analysis and post processing

Updating ‘My’ in Masonry with Spandrel Type

• Add a building type. Building type had ‘New Buildings’ and ‘Existing Buildings’
• Set a default value of D/H according to the building type

Default Values of D/H


New Existing
Point
Building Building

C 0.008 0.015

D 0.008 0.015

9 /39
midas Gen Gen 2020 v2.1 Release Note

3. Improvement about masonry pushover analysis and post processing

Updating Fy in Masonry with Spandrel hinge Type

• Improvement of formula for shear resistance in irregular type

Shear Resistance =
Min. [ 𝑉 ℎ𝑡𝑓 ,𝑉 2𝑀 /𝑙 ]

where

Shear Resistance =

Min. [ 𝑉 𝐿𝑇1.5𝑓 /𝛽 1 𝑃/1.5𝑓 ,𝑉 2𝑀 /𝑙 ]

where

10 /39
midas Gen Gen 2020 v2.1 Release Note

4. Energy result graph & additional damping ratio in time‐history analysis results

Improvement of Energy Result Graph : Energy Percentage Result of all step

[New] Energy Percentage Result of all step


 Click to display text window

[Exiting] Energy Percentage Final Step Result

11 /39
midas Gen Gen 2020 v2.1 Release Note

4. Energy result graph & additional damping ratio in time‐history analysis results

Add Additional Damping Ratio of Energy Dissipation System

[New] Additional Damping Ratio Result of


final step
 Click to display text window

12 /39
midas Gen Gen 2020 v2.1 Release Note

4. Energy result graph & additional damping ratio in time‐history analysis results

Add Additional Damping Ratio of Energy Dissipation System

[New] Energy Percentage Result of all step


 Click to display text window

13 /39
midas Gen Gen 2020 v2.1 Release Note

5. Add reaction table for each step in Pushover

Add Reaction Table for each step in PUSHOVER

4
1

Step 1. Open Records Activation Dialog box.

Step 2. Select Load case for pushover.

Step 3. Select Pushover step.

Step 4. Printout Reaction table

14 /39
Gen 2020 v2.1 Release Note

6. Select Inelastic Hinge Result Output in Inelastic time history analysis

• Properties > Inelastic Properties > Inel. Control Data > Select Inelastic Hinge Result Output(Element/General Link)
• Load > Dynamic Loads > Time History Analysis Data > Global Control

Select the element to print Select General Link to print Inelastic Hinge Status Result
- Press ‘Add/Replace’ button after - Press ‘Add’ button after - Check result of selected elements
selecting element on model view - Selecting GL-Link
-

Global Control Setting


- Set to output selected elements

- By setting to output only the results of the selected element,


- It can be shorten the analysis time and check the required results.

15 /39
Gen 2020 v2.1 Release Note

6. Select Inelastic Hinge Result Output in Inelastic time history analysis

Global Control Setting Inelastic Hinge Status Result

- Set to Max/Min Result Only - Check Max/Min result output

16 /39
Gen 2020 v2.1 Release Note

7. Improvement in analysis speed for inelastic time history analysis

• Reduction of analysis time by optimizing the inelastic time history analysis program and improving the output algorithm for
inelastic analysis results

3D Fiber Wall Model (23F) 3D Structure Hinge Model (12F)

17 /39
Gen 2020 v2.1 Release Note

8. Add result summary table of fiber beam and wall for inelastic hinge 

• Results > Results Tables > Inelastic Hinge > Fiber Beam Summary, Fiber Wall Summary

Fiber Beam Summary

Fiber Wall Summary

18 /39
midas Gen Gen 2020 v2.1 Release Note

9. Revit 2020 Interface

Gen-Revit Link
Functions Revit <> Gen
Structural Column   <>
 File > Import > midas Gen MGT File Beam   <>
Linear  Brace   <>
 File > Export > midas Gen MGT File
Elements Curved Beam   >
Beam System   >
Truss   >
Foundation Slab   <>
Structural Floor   <>
Planar Structural Wall   <>
Elements Wall Opening & Window   >
Door   >
Vertical or Shaft Opening   >
Offset   >
Rigid Link   >
Cross‐Section Rotation   >
End Release   >
Boundary Isolated Foundation Support   >
Point Boundary Condition   >
Line Boundary Condition   >
Send Model to midas Gen Wall Foundation   >
Area Boundary Condition   >
Load Nature   >
Load Case   >
Load Combination   >
Load
Hosted Point Load   >
Hosted Line Load   >
Hosted Area Load   >
Other  Material   <>
Parameters Level >

Revit 2020 Gen2020

19 /39
midas Gen Gen 2020 v2.1 Release Note

10. Non‐dissipative element design for slab as per NTC2018

Add non-dissipative element design for slab.

• M-Curvature Curve of Slab

• Slab Design as Non-dissipative element


Strength (ULS)
H
: Shear design uses only load Comb. Of Gravity loads

Strength (ELS) (Add) B (Width by unit)


: Flexural design uses only ELS load Comb..

20 /39
midas Gen Gen 2020 v2.1 Release Note

11. Improvement of slab design as per EC2 and NTC

Add “Check ratio of x/d” and “Check Stress by Quasi-permanent Load combinations”
Check x/d as per NTC2018 4.1.2.1.2.1 Stress check by Quasi-permanent

21 /39
midas Gen Gen 2020 v2.1 Release Note

12. Improvement of Non‐dissipative Design 

Add Approximate Method : M’yd = Reduction factor * MRd

Setting of Concrete Design Code Beam Design Report

* M_Rd
0.9
M_yd’ =
Add Option

22 /39
Gen 2020 v2.1 Release Note

13. Improvement of inelastic material model

Apply “Partial Safety Factor” in Inelastic Material Model


• Analysis according to design strength instead of ultimate strength (fyd = fyk / Partial safety factor)
• Apply to fiber model in pushover analysis and generation of M-C curve in non-dissipative design
Concrete Steel

Add inelastic model types for Conc. And Rebar (apply partial safety factor)
-Concrete : Parabola Rectangle or Bilinear model
-Rebar : bilinear model (SP63Add inelastic model types for Conc. And Rebar (apply
partial safety factor)-Concrete : Parabola Rectangle or Bilinear model-Rebar : bilinear
model (SP63)

23 /39
midas Gen Gen 2020 v2.1 Release Note

14. Improvement of Joint design as per EC2 and NTC

Improvement the check for hoop spacing in joint design

Detail report

Review for constructability

Design result table


Printout “J” in red color In Design result table
If sh.use < sh,min.

Graphic result

Printout “Check Spacing” In graphic If sh.use < sh,min.

24 /39
midas Gen Gen 2020 v2.1 Release Note

14. Improvement of Joint design as per EC2 and NTC

Joint Design as per EC and NTC


 Improvement to check a hoop area and spacing in Joint design
ㄴㄴㄴㄴ 1) For Ash_req 1(EC2:04 _5.5.3.3(3))
Detail report

2) For Ash_req2(EC2:04_5.5.3.3.(4))

• Ash_req = Min[Ash_req1, Ash_req2]


Design result table

Printout the result for Ash,req instead of Vjh

Graphic result
Change the results based on the hoop rebar area required

25 /39
midas Gen Gen 2020 v2.1 Release Note

14. Improvement of Joint Design as per EC2 and NTC

Joint Design as per EC and NTC

• Add option to design selectively for ‘Confined’ and ‘Not confined’ joint condition

Setting of Concrete Design Code

Add Joint design

Add Option

26 /39
midas Gen Gen 2020 v2.1 Release Note

15. Cyclic shear resistance check as per EN1998‐3:2005 & NTC2018

Check of Cyclic shear Resistance under ULS Design

• Design > result > Concrete Design > Cyclic Shear Resistance

Result Table for Cyclic shear Resistance checking

Set Cyclic Shear Resistance Parameters

Demand : Design Shear Force

Capacity : VR by Equation below

A.3.3 Beams, columns and walls: shear

Demand ≤ Capacity  O.K


Demand > Capacity  N.G.

27 /39
midas Gen Gen 2020 v2.1 Release Note

15. Cyclic shear resistance check as per EN1998‐3:2005 & NTC2018

Check of Cyclic shear Resistance under Pushover analysis

• Pushover > Pushover Hinge Result > Cyclic Shear Resistance

Result Table for Cyclic shear Resistance checking

Set Cyclic Shear Resistance Parameters

Demand : Design Shear Force

Capacity : VR by Equation below

A.3.3 Beams, columns and walls: shear

Demand ≤ Capacity  O.K


Demand > Capacity  N.G.

28 /39
Gen 2020 v2.1 Release Note

16. Improvement  of hinge model as per EC

Improvement of Hinge model as per EC

Current Version Release version

29 /39
Gen 2020 v2.1 Release Note

midas Design+

30 /39
midas Gen Gen 2020 v2.1 Release Note

1. Steel design tool as per AISC 341‐16

Calculation
of Unbraced Length
of Beam bracing

Beam bracing

*Ry = 1.1 usually.

31 /39
midas Gen Gen 2020 v2.1 Release Note

1. Steel design tool as per AISC 341‐16

Calculation
of axial strength
of Point Bracing
-1

Beam bracing
as point bracing

32 /39
midas Gen Gen 2020 v2.1 Release Note

1. Steel design tool as per AISC 341‐16

Calculation
of axial strength
of Point Bracing
-2

33 /39
midas Gen Gen 2020 v2.1 Release Note

1. Steel design tool as per AISC

Design of
Link Stiffener
for I - sections

34 /39
midas Gen Gen 2020 v2.1 Release Note

1. Steel design tool as per AISC 341‐16

Design of
Link Stiffener
for I - sections

35 /39
midas Gen Gen 2020 v2.1 Release Note

1. Steel design tool as per AISC

Calculation
of Beam Strength
with K-brace

36 /39
midas Gen Gen 2020 v2.1 Release Note

2. Anchor bolt module as per ACI 318

 Applied Code : ACI318-14(M),11(M),08(M),NSR-10


 Spacing, Tensile, Shear Strength, and Combined Ratio Check for Post-Installed / Cast-In-Place Anchor Bolt

37 /39
midas Gen Gen 2020 v2.1 Release Note

2. Anchor bolt module as per ACI

Procedure of Anchor Bolt Design

Section Force Anchor Layout

Step 4.
Step 2. Define the layout type & spacing
Define Force Data. Number of Anchor bolt.
(Axial, Moment, Shear, Torsion)

Step 3.
Define Anchor Bolt information.

Cast-In-Place Anchor : Headed Stud / Headed Bolt/Hooked Bolt(L/J)


Step 1. Post-Installed Anchor:
Define concrete, Anchor bolt material Expansion(Torque, Displacement), Undercut, Adhesive anchors
and element information.

38 /39
midas Gen Gen 2020 v2.1 Release Note

2. Anchor bolt module as per ACI

Summary Calculation Report Detail Calculation Report

- Choose Summary/Detail Calculation Report


- Easy to check by printing standard(code)chapter in detail
calculation report.

39 /39

You might also like