NOTES:

A B C D E F G 1. Drawing and dimensions are


only to be read and not scaled.
2. Unless otherwise mentioned,
all dimensions are given in MM.
3. This drawing shall be read
in conjuction with relevant
F4 architectural, structural and
F2 PLINTH BEAM
services drawings.
F1 F2
4. All levels given in drawing
9 are with reference to the
Road Level as benchmarked
at site
5. Any discrepancy between
N.G.LVL.
the architectural/ structural
F1 or services drawings must be
F2 brought to the attention of
TYP. COL.
the architect by the
8 contractor or project
manager, before execution of
the same.
6. All post completion
construction shall be
responsibility of the Owner.
F2 Structural Engineers shall not be
7 held responsible for it.
7. Site supervision is responsibility
6 of construction agency & owner.
8. Conc. mix M25.
100MM THK P.C.C. (1:4:8) AS/SCHEDULE
9. Reinf. Fe 500.
10. Structural specifications shall
be as I.S. 456-2000, I.S. 1893
(part-1)2016 & I.S. 13920-2016.
TYPICAL SECTION FOR FOOTING
5
F2

FOOTING SCHEDULE
3
DEPTH BOTTOM REINFORCEMENT
FOOTING FOOTING SIZES
S.NOS. (LxB) (D)
NOS. ALONG ( L ) ALONG ( B )
F2 F2
F1 10 @100C/C 10 @100C/C

2 12 @125C/C 12 @125C/C

12 @100C/C 12 @100C/C

12 @100C/C 12 @100C/C

F4 F4
F2 F2

COLUMN LAYOUT

PROJECT:- STRUCTURAL CONSULTANTS CHARTERED ER. ROHIT BANSAL


M.TECH (STRUCTURES)
Drg. Title FOUNDATION PLAN & DETAIL (ADMINISTRATIVE BLOCK)
Eng.Chk.
A-ONE ASSOCIATES Designed ROHIT BANSAL
Drawn by Coordination
INDUSTRIAL SHED, MILAKPUR, HARYANA STRUCTURE DESIGNERS, ENGINEERS, VALUERS VSR
ROHINI, NEW DELHI-110085 Date 07/03/2023 Approved
email id : aoneassociates.2012@gmail.com
DRG NO ST-01 CAD file