You are on page 1of 4

BERMAD Waterworks BERMAD Waterworks BERMAD Waterworks

700 Series 700 Series 700 Series


Model 720 Model 720 Model 720
Typical Applications Technical Data
Pressure Reducing System for Municipal Networks
Network design requires establishing various pressure zones due to topography, distances, demands, energy costs,
Dimensions and Weights
Size
mm inch
A, B
mm inch
C
mm inch
L
mm inch
H
mm inch
Weight
kg lbs C
Flow Chart

1.0
50 100
Flow Rate - gpm
500 1,000 5,000 10,000
10
Vana de Reducere
a Presiunii
reservoir availability, etc. 40 11/2” 350 14 180 7 205 8.1 239 9.4 9.1 20 0.9 9
0.8 8
50 2 350 14 180 7 210 8.3 244 9.6 10.6 23 0.7 7
65 21/2” 350 14 180 7 222 8.7 257 10.1 13 29 0.6 6

Pressure Loss - bar


H

Pressure Loss - psi


80 3” 370 15 230 9 250 9.8 305 12.0 22 49 0.5 5
100 4”
150 6”
395 16
430 17
275 11
385 15
320 12.6
415 16.3
366 14.4
492 19.4
37 82
75 165 L
0.4 24” 4 ■ Reducerea debitului si a exfiltratiilor
1.5" 3" 6" 10" 14" 18" 28"
200 8” 475 19 460 18 500 19.7 584 23.0 125 276 0.3
2" 4" 8" 12" 16" 20" 30"
3 ■ Protectie anti-cavitatie
250 10” 520 21 580 23 605 23.8 724 28.5 217 478
300 12” 545 22 685 27 725 28.5 840 33.1 370 816
A 0.2
2.5" 32"
2 ■ Reducerea zgomotului de
350 14” 545 22 685 27 733 28.9 866 34.1 381 840
400 16” 645 26 965 38 990 39.0 1108 43.6 846 1865 inchidere/restrictie a debitului
B
450 18”
500 20”
645 26
645 26
965 38
965 38
1000 39.4
1100 43.3
1127 44.4
1167 45.9
945 2083
962 2121 0.1 1 ■ Protectie avarii conducta
Data is for Y-pattern, flanged, PN16 valves
Weight is for PN16 basic valves
10
50
100
500
1,000
5,000
10,000 ■ Reducerea costurilor de mentenanta
Flow Rate - m3/h
“C” enables removing the actuator in one unit
“L”, ISO standard lengths available
For more dimensions and weights tables, refer to Engineering Section
Data is for Y-pattern, flat disk valves
For more flow charts, refer to Engineering Section Modelul 720 Vana de Reducere a Presiunii este o vana
Main Valve Control System Pilot Valve Selection de control operata hidraulic, actionata de diafragma,
Valve Patterns: “Y” (globe) & angle Standard Materials: Pilot Type
care reduce presiunea mare din amonte la o presiune
Valve Size Pilot
Size Range: 11/2–32” (40-800 mm) Accessories: Setting (bar) #2PB #2 #2HC mai scazuta constanta in aval, indiferent de variatia
End Connections (Pressure Ratings): Bronze, Brass, Stainless Steel & NBR 11/2-10” <15
Flanged: ISO PN16, PN25 Tubing: Copper or Stainless Steel 40-250 mm >15 consumului si a presiunii din amonte.
(ANSI Class 150, 300) Fittings: Forged Brass or Stainless Steel
6-14” <15
The pump supplies water to the network and to the reservoir. System pressure is too high for the residential Threaded: BSP or NPT Pilot Standard Materials:
150-350 mm >15
Others: Available on request Body: Brass, Bronze or Stainless Steel
neighborhood, requiring a pressure reducing system. Working Temperature: Elastomers: NBR 16 -32” <15
Water up to 80°C (180°F) Springs: Galvanized Steel or Stainless Steel 400-800 mm >15
Standard Materials: Internals: Stainless Steel Standard model with high pressure setting kit
Pressure Reducing System – Typical Installation Body & Actuator: Ductile Iron
Internals:
Stainless Steel, Bronze & coated Steel
Pressure Reducing Valve Diaphragm:
Model 720 NBR Nylon fabric-reinforced
Seals: NBR
Relief Valve Coating:
Model 73Q Fusion Bonded Epoxy, RAL 5005 (Blue) Caracteristici si Beneficii Caracteristici suplimentare importante
NSF & WRAS approved or Electrostatic
Polyester Powder, RAL 6017 (Green) ■ Actionare linie de presiune – Operatie independenta ■ UL pentru protectie la incendiu – FP-720-UL
How to Order ■ Servisare in serie – Mentenanta usoara ■ Control cu Solenoid – 720-55
Please specify the requested valve in the following sequence: (for more options, refer to Ordering Guide)
■ Design cu camera dubla ■ Vana de retinere– 720-20
Strainer ❏ Reactie moderata a vanei ■ Control cu Solenoid & Vana de retinere – 720-25
Model 70F Primary Additional Body End Voltage & Tubing Additonal
Sector Size Feature Feature Pattern Material Connections Coating Position & Fittings Attributes ❑ Diafragma protejata ■ Proportionala – 720-PD

WW
- 6”
- 720- 00
- -Y -C 16 EB – CB VI
■ Design flexibil – Adaugare facila a caracteristicilor ■ Control automat regularizare – 720-09
■ Varietate de accesorii – Potrivire exacta ■ Pilot de mare sensibilitate – 720-12
By-Pass
Pressure Reducing Valve Waterworks 1 /2 - 32”
1
Pressure Reducing Oblique (up to 20”) Y Epoxy FB Blue EB Copper Tubing & Brass Fittings CB
■ Corp cu deschidere mare,"Y" sau in unghi - Minimizeaza ■ Vana de reducere a presiunii in caza de urgenta – 20-PD-59
Model 720 Angle (up to 18”) A Polyester Green PG Plastic Tubing & Brass Fittings PB pierderile de presiune ■ Protectie suprapresiune aval – 720-48
Globe (24-32” only) G Polyester Blue PB St. St. 316 Tubing & Fittings NN ■ Flux semi-liniar – Debit non-turbulent
Uncoated UC ■ Setare pe mai multe niveluri cu selectare electrica – 720-45
In addition to the Model 720 Pressure Reducing Valve, BERMAD recommends that the system also include: Valve Position Indicator I ■ Scaun din otel inoxidabil – Rezistenta la cavitatie
■ Strainer Model 70F prevents debris from damaging valve operation ■ Setare electronica pe mai multe niveluri, Tip 4T – 720-4T
No Additional Feature 00 Ductile Iron Standard C V-Port Throttling Plug V
■ Orificiu complet deschis, fara obstructiuni - Fiabilitate mare
■ Relief Valve Model 73Q provides: Closing and Opening Speed Control 03 Cast Steel S Large Control Filter F ■ Vana de reducere a presiunii electronica – 728-03
❏ Protection against momentary pressure peaks
Automatic Regulation Override 09 St. Steel 316 N Electric Limit Switch S ■ V-Port cep de restrictie – Stabilizarea debitelor mici
High sensitivity pilot 12 Nickel Alumin. Bronze U 3-Way Control Loop X
❏ Visual indication of need for maintenance Check Valve 20 24VAC/50Hz - N.C. 4AC Valve Position Transmitter Q Vezi publicatii Bermad relevante
Solenoid Controlled & Check Valve 25 ISO-16 16 24VAC/50Hz - N.O. 4AO St. St. 316 Control Accessories N
■ By-Pass Pressure Reducing Valve saves on maintenance costs. The larger (more costly to maintain) valve operates
Multi-Setting Levels - Electrically Selected 45 ISO-25 25 24VDC - N.C. 4DC St. St. 316 Internal Trim (Closure & Seat) T
during peak demand. The smaller by-pass valve cuts operating hours of the larger valve, achieving greater Downstream Over Pressure Guard 48 ANSI-150 A5 24VDC - N.O. 4DO St. St. 316 Actuator Internal Assembly D
return on investment. Hydraulic Control 50 ANSI-300 A3 24VDC - L.P. 4DP Delrin Bearing R
Solenoid Controlled 55 JIS-16 J6 220VAC/50-60Hz N.C. 2AC Viton Elastomers for Seals & Diaphragm E
For high differential pressure systems, see BERMAD publication 720-PD Proportional Pressure Reducing Valve. Electric Override 59 JIS-20 J2 220VAC/50-60Hz N.O. 2AO Pressure Gauge 6
Multiple choices permitted Use when additional electric control Multiple choices permitted
For high pressure systems, see BERMAD publication 820 Piston Actuated Pressure Reducing Valve. feature is selected

info@bermad.com • www.bermad.com
The information herein is subject to change without notice. BERMAD shall not be held liable for
any errors. All rights reserved. © Copyright by BERMAD. PC7WE20 05
BERMAD Waterworks BERMAD Waterworks BERMAD Waterworks
700 Series 700 Series 700 Series
Model 720 Model 720 Model 720
Operare Pressure Reducing Systems in High-Rise Buildings Higher Zone Installation A
Water supply system design requirements for high-rise In addition to the municipal pressure reducing system for a high-rise building, BERMAD recommends the
Modelul 720 este o vana controlata de un sistem pilot, echipata cu pilot de reducere a presiunii cu 2 cai.
buildings present unique issues: system also include:
Vana inelara [1] in mod continuu, permite accesul debitului de apa din orificiul de intrare al vanei in camera superioara [2]. ■ Supply cut-off is unacceptable and single source supply
D
■ Parallel Redundant Branches ensuring uninterrupted supply by enabling unskilled personnel to temporarily
G
Pilotul [3] "simte" presiunea de iesire. is common. shut off one of the branches.
Daca aceasta presiune creste peste presiune setata in pilot, pilotul se inchide, permitand acumularea presiunii in camera ■ Valves are located in areas where water damage can ■ Emergency System including a downstream pressure switch and an Emergency Valve Model 720-PD-59.

superioara, determinand inchiderea vanei principale, astfel determinanad scaderea presiunii de iesire la cea setata in pilot. be extremely expensive. ❏ Pressure Switch [6] signals a control panel of excessive downstream pressure.

Daca presiunea de iesire scade sub presiunea setata in pilot, pilotul face descarcarea presiunii acumulate si vana principala se va ■ Pressure reducing systems are often located next to ❏ Emergency Valve [2] is fully open during normal operation. Triggered by the control panel, it becomes a

deschide modular. Orificiul integrat dintre camera inferioara de control si orificiul de iesire al vanei modereaza reactia vanei. prestigious residential and office space. Extraneous proportional pressure reducing valve.
noise and maintenance activities are to be avoided.
Vana inelara controleaza viteza de inchidere. Supapa din aval [4] permite inchiderea manuala. ■ The main supply line of high-rise buildings is exposed
Control Panel [6]
to greater head at lower zones while pressure for the
1 1/2-10” 6-14” consumer must be kept within recommended levels.
cu #2PB Pilot cu #2 Pilot As a result, lower zone pressure reducing systems deal [2] [3]
[5]

[3] [3] with greater differential pressure.


[1]
The Model 720 Pressure Reducing Valves together [1] Strainer Model 70F
[1] ➊ with BERMAD’S accumulated experience address these
[4] [2] Emergency Pressure Reducing
issues and provide appropriate solutions. Valve Model 720-PD-59
[1]
[3] Pressure Reducing Valve
[5] Model 720
[2] [2]
A [3] [4] By-pass Pressure Reducing
Valve Model 720
[5] Relief Valve Model 73Q
[4] [4] [6] Pressure Switch

A
Lower Zone (Two-Stage) Installation B
Nota: Pentru vane de 16" sau mai mari, a se
vedea tabelul cu "Selectia pilotului" la ultima When dealing with high differential pressure systems in lower zones of a high-rise building, BERMAD recommends a
pagina
two-stage pressure reducing system. In addition to the typical higher zone installation, this high differential pressure
Specificatii Tehnice system also includes:
■ Proportional Pressure Reducing Valve Model 720-PD, as the first pressure reducing stage, absorbs part of the
Vana de Reducere a Presiunii trebuie sa reduca presiunea ridicata din amonte la o presiune scazuta presetata din aval,
A high differential pressure. By spreading the load of pressure reducing onto two components, cavitation damage and
indiferent de variatia consumului sau de variatia presiunii din amonte.
noise are reduced.
Vana Principala: Vana principala trebuie sa fie o vana ghidata central, actionata de diafragma, de forma glob sau oblica "Y", sau
avand design in unghi. Corpul trebuie sa aiba inelul din inox al scaunului inlocuibil. Vana trebuie sa aiba o curgere libera a Control Panel
[1] Strainer Model 70F
[10]
debitului, fara tije de ghidare, rulmenti sau nervuri de sprijin. Corpul si capacul trebuie sa fie din fonta ductila. Toate suruburile [2] Emergency Pressure Reducing
Valve Model 720-PD-59
externe, piulitele si stifturile trebuie sa aiba o acoperire Duplex®. Toate componentele vanei trebuie sa fie accesibile si usor de [2] [5]
B [3] [9] [3] Proportional Pressure Reducing
reparat fara sa scoatem vana de pe conducta. [7]
Valve Model 720-PD
[1]
Actionarea: Ansamblul de actionare trebuie sa fie prevazut cu doua camere de control, cu o suprafata se separatie intre [4] By-Pass Proportional Pressure
Reducing Valve Model 720-PD
suprafata inferioara a diafragmei si vana principala. Intregul sistem de actionare (capacul superior) trebuie sa poata fi indeparat
[4] [6] [5] Primary Relief Valve Model 73Q
de corpul vanei, ca o parte integrala. Arborele din inox al vanei ar trebui sa fie ghidat central de un rulment in suprafata de [8]
[6] By-Pass Relief Valve Model 73Q
separatie. Discul inlocuibil de etansare radial trebuie sa includa o etansare din cauciuc si trebuie sa permita montarea [7] Pressure Reducing Valve
B
V-Port-ului prin filetare. A Higher zone pressure reducing system installation Model 720
E
E FF [3] [5] [9]
B Lower zone pressure reducing system C
C [7] [8] By-Pass Pressure Reducing
Sistemul de control: Sistemul de control consta in intr-o vana pilot de reducere a presiunii, ajustabila, cu doua cai, cu actionare Valve Model 720
(two-stage) installation
directa, supapa inelara, vane de izolare "cock valves" si un filtru. Toate fitingurile trebuie sa fie din alama forjata sau din inox. C Bottom reservoir level control system [9] Relief Valve Model 73Q
Vana asamblata trebuie sa fie testata hidraulic si ajustata din fabrica dupa cerintele clientului. D Roof reservoir level control system [10] Pressure Switch
E Potable water pumping system
Asigurarea calitatii: Vana trebuie sa fie certificata conform certificatului de calitate standard ISO 9001. Vana principala trebuie sa F Fire protection pumping system For high differential pressure systems, see BERMAD publication 720-PD Proportional Pressure Reducing Valve.
fie certificata pentru apa potabila conform cuNSF, WRAS si alte standarde recunoscute. G Upper floors pumping system For high pressure systems, see BERMAD publication 820 Piston Actuated Pressure Reducing Valve.
BERMAD Waterworks BERMAD Waterworks BERMAD Waterworks
700 Series 700 Series 700 Series
Model 720 Model 720 Model 720
Applicatie standard Technical Data
Flow Chart
Vana de reducere a presiunii pentru retelele municipale
Proiectarea retelei necesita stabilirea diferitelor zone de presiune in functie de topografie, distanta, consum, costul
Dimensions and Weights
Size
mm inch
A, B
mm inch
C
mm inch
L
mm inch
H
mm inch
Weight
kg lbs C 1.0
50 100
Flow Rate - gpm
500 1,000 5,000 10,000
10
Pressure Reducing
energiei, disponibilitate rezervor etc. 40 11/2”
50 2
65 21/2”
350 14
350 14
350 14
180 7
180 7
180 7
205 8.1
210 8.3
222 8.7
239 9.4
244 9.6
257 10.1
9.1 20
10.6 23
13 29
0.9
0.8
0.7
0.6
9
8
7
6
Valve

Pressure Loss - bar


H

Pressure Loss - psi


80 3” 370 15 230 9 250 9.8 305 12.0 22 49 0.5 5
100 4”
150 6”
395 16
430 17
275 11
385 15
320 12.6
415 16.3
366 14.4
492 19.4
37 82
75 165 L
0.4 24” 4 ■ Flow and leakage reduction
1.5" 3" 6" 10" 14" 18" 28"
200 8” 475 19 460 18 500 19.7 584 23.0 125 276 0.3
2" 4" 8" 12" 16" 20" 30"
3
■ Cavitation damage protection
250 10” 520 21 580 23 605 23.8 724 28.5 217 478
300 12” 545 22 685 27 725 28.5 840 33.1 370 816
A 0.2
2.5" 32"
2 ■ Throttling noise reduction
350 14” 545 22 685 27 733 28.9 866 34.1 381 840
400 16” 645 26 965 38 990 39.0 1108 43.6 846 1865 ■ Burst protection
450 18” 645 26 965 38 1000 39.4 1127 44.4 945 2083 B
500 20” 645 26 965 38 1100 43.3 1167 45.9 962 2121 0.1 1 ■ System maintenance savings
50 500 5,000
Data is for Y-pattern, flanged, PN16 valves 10 100 1,000 10,000
Weight is for PN16 basic valves Flow Rate - m3/h
“C” enables removing the actuator in one unit
“L”, ISO standard lengths available Data is for Y-pattern, flat disk valves
For more dimensions and weights tables, refer to Engineering Section For more flow charts, refer to Engineering Section The Model 720 Pressure Reducing Valve is a hydraulically
Main Valve Control System Pilot Valve Selection operated, diaphragm actuated control valve that reduces
Valve Patterns: “Y” (globe) & angle Standard Materials: Pilot Type
higher upstream pressure to lower constant downstream
Valve Size Pilot
Size Range: 11/2–32” (40-800 mm) Accessories: Setting (bar) #2PB #2 #2HC pressure regardless of fluctuating demand or varying
End Connections (Pressure Ratings): Bronze, Brass, Stainless Steel & NBR 11/2-10” <15 upstream pressure.
Flanged: ISO PN16, PN25 Tubing: Copper or Stainless Steel 40-250 mm >15
(ANSI Class 150, 300) Fittings: Forged Brass or Stainless Steel
6-14” <15
Pompa alimenteaza atat reteaua cat si rezervorul. Presiunea din sistem este prea mare pentru alimentarea Threaded: BSP or NPT Pilot Standard Materials:
150-350 mm >15
Others: Available on request Body: Brass, Bronze or Stainless Steel
zonei rezidentiale, este necesara reducerea presiunii in sitem. Working Temperature: Elastomers: NBR 16 -32” <15
Water up to 80°C (180°F) Springs: Galvanized Steel or Stainless Steel 400-800 mm >15
Standard Materials: Internals: Stainless Steel Standard model with high pressure setting kit
Sistem de reducere a presiunii–Instalare Tipica Body & Actuator: Ductile Iron
Internals:
Stainless Steel, Bronze & coated Steel
Pressure Reducing Valve Diaphragm:
Model 720 NBR Nylon fabric-reinforced
Seals: NBR
Relief Valve Coating:
Model 73Q Fusion Bonded Epoxy, RAL 5005 (Blue) Features and Benefits Major Additional Features
NSF & WRAS approved or Electrostatic
Polyester Powder, RAL 6017 (Green) ■ Line pressure driven – Independent operation ■ UL Listed for fire protection – FP-720-UL
■ In-line serviceable – Easy maintenance ■ Solenoid control – 720-55
How to Order
■ Double chamber design ■ Check valve – 720-20
Please specify the requested valve in the following sequence: (for more options, refer to Ordering Guide)
Strainer ❏ Moderated valve reaction ■ Solenoid control & check valve – 720-25
Model 70F Primary Additional Body End Voltage & Tubing Additonal
Sector Size Feature Feature Pattern Material Connections Coating Position & Fittings Attributes ❑ Protected diaphragm ■ Proportional – 720-PD
■ Flexible design – Easy addition of features ■ Automatic regulation override – 720-09
WW
- 6”
- 720- 00
- -Y -C 16 EB – CB VI
■ Variety of accessories – Perfect mission matching ■ High sensitivity pilot – 720-12
By-Pass ■ ■
Pressure Reducing Valve Waterworks 1 1/2 - 32” Pressure Reducing Oblique (up to 20”) Y Epoxy FB Blue EB Copper Tubing & Brass Fittings CB
"Y" or angle, wide body – Minimized pressure loss Emergency pressure reducing valve – 720-PD-59
Model 720 Angle (up to 18”) A Polyester Green PG Plastic Tubing & Brass Fittings PB ■ Semi-straight flow – Non-turbulent flow ■ Downstream over pressure guard – 720-48
Globe (24-32” only) G Polyester Blue PB St. St. 316 Tubing & Fittings NN
■ Stainless Steel raised seat – Cavitation damage resistant ■ Electrically selected multi-level setting – 720-45
Suplimentar, pe langa modelul 720 Vana de Reducere a Presiunii, BERMAD recomanda ca sistemul sa includa de asemenea: Uncoated UC
Valve Position Indicator I
■ Obstacle free, full bore – Uncompromising reliability ■ Electronic multi-level setting, Type 4T – 720-4T
■ Filtru Model 70F previne avarierea vanei de la resturile ramase No Additional Feature 00 Ductile Iron Standard C V-Port Throttling Plug V
■ Relief Valve Model 73Q ofera:
Closing and Opening Speed Control 03 Cast Steel S Large Control Filter F ■ V-Port Throttling Plug – Low flow stability ■ Electronic pressure reducing valve – 728-03
Automatic Regulation Override 09 St. Steel 316 N Electric Limit Switch S
❏ Protectie impotriva "varfurilor" de presiune High sensitivity pilot 12 Nickel Alumin. Bronze U 3-Way Control Loop X
❏ Indicator vizual in caz de mentenanta Check Valve 20 24VAC/50Hz - N.C. 4AC Valve Position Transmitter Q See relevant BERMAD publications.
Solenoid Controlled & Check Valve 25 ISO-16 16 24VAC/50Hz - N.O. 4AO St. St. 316 Control Accessories N
■ By-Pass Pressure Reducing Valve salveaza costurile de mentenanta. Multi-Setting Levels - Electrically Selected 45 ISO-25 25 24VDC - N.C. 4DC St. St. 316 Internal Trim (Closure & Seat) T
Downstream Over Pressure Guard 48 ANSI-150 A5 24VDC - N.O. 4DO St. St. 316 Actuator Internal Assembly D
Hydraulic Control 50 ANSI-300 A3 24VDC - L.P. 4DP Delrin Bearing R
Solenoid Controlled 55 JIS-16 J6 220VAC/50-60Hz N.C. 2AC Viton Elastomers for Seals & Diaphragm E
Electric Override 59 JIS-20 J2 220VAC/50-60Hz N.O. 2AO Pressure Gauge 6
Multiple choices permitted Use when additional electric control Multiple choices permitted
feature is selected

info@bermad.com • www.bermad.com
The information herein is subject to change without notice. BERMAD shall not be held liable for
any errors. All rights reserved. © Copyright by BERMAD. PC7WE20 05
BERMAD Waterworks BERMAD Waterworks BERMAD Waterworks
700 Series 700 Series 700 Series
Model 720 Model 720 Model 720
Typical Applications Date Tehnice
Dimensiuni si greutate Grafic debit
Pressure Reducing System for Municipal Networks
Network design requires establishing various pressure zones due to topography, distances, demands, energy costs,
Size
mm inch
A, B
mm inch
C
mm inch
L
mm inch
H
mm inch
Weight
kg lbs C 1.0
50 100
Flow Rate - gpm
500 1,000 5,000 10,000
10
Pressure Reducing
reservoir availability, etc. 40 11/2”
50 2
65 21/2”
350 14
350 14
350 14
180 7
180 7
180 7
205 8.1
210 8.3
222 8.7
239 9.4
244 9.6
257 10.1
9.1 20
10.6 23
13 29
0.9
0.8
0.7
0.6
9
8
7
6
Valve

Pressure Loss - bar


H

Pressure Loss - psi


80 3” 370 15 230 9 250 9.8 305 12.0 22 49 0.5 5
100 4”
150 6”
395 16
430 17
275 11
385 15
320 12.6
415 16.3
366 14.4
492 19.4
37 82
75 165 L
0.4 24” 4 ■ Flow and leakage reduction
1.5" 3" 6" 10" 14" 18" 28"
200 8” 475 19 460 18 500 19.7 584 23.0 125 276 0.3
2" 4" 8" 12" 16" 20" 30"
3
■ Cavitation damage protection
250 10” 520 21 580 23 605 23.8 724 28.5 217 478
300 12” 545 22 685 27 725 28.5 840 33.1 370 816
A 0.2
2.5" 32"
2 ■ Throttling noise reduction
350 14” 545 22 685 27 733 28.9 866 34.1 381 840
400 16” 645 26 965 38 990 39.0 1108 43.6 846 1865 ■ Burst protection
450 18” 645 26 965 38 1000 39.4 1127 44.4 945 2083 B
500 20” 645 26 965 38 1100 43.3 1167 45.9 962 2121 0.1 1 ■ System maintenance savings
50 500 5,000
Datele sunt pentru modelul Y, flansat, PN16 10 100 1,000 10,000
Greutatea PN16 basic valves Debit m3/h
“C” permite indepartarea actionarii intr-o singura unitatet
Data is for Y-pattern, flat disk valves
“L”, ISO standard lungimi disponibile For more flow charts, refer to Engineering Section The Model 720 Pressure Reducing Valve is a hydraulically
Vana de baza Sistem de Control Pilot Valve Selection operated, diaphragm actuated control valve that reduces
Model: “Y” (glob) & tip unghi Materiale Standard Pilot Type
higher upstream pressure to lower constant downstream
Pilot
Dimensiuni: 1 /2–32” (40-800 mm) C
Valve Size
1
Acesorii: Setting (bar) #2PB #2 #2HC pressure regardless of fluctuating demand or varying
Conexiuni (Gama de presiune): Bronz, Alama, Inox & tuburi NBR : Cupru sau 11/2-10” <15 upstream pressure.
Flansate: ISO PN16, PN25 Inoxl 40-250 mm >15
(ANSI Class 150, 300) Fitinguri: Alama forjata sau otel inox 6-14” <15
The pump supplies water to the network and to the reservoir. System pressure is too high for the residential Filetate: BSP sau NPT Materiale Standard Pilot : 150-350 mm >15
neighborhood, requiring a pressure reducing system. Altele: Disponibile la cerere Corp: Alama, Bronz sau Otel inox 16 -32” <15
Temperatura de lurcu:
Elastomeri: NBR 400-800 mm >15
Apa pana la 80°C (180°F)
Materiale Standard: Arc: Otel galvanizat sau Inox Standard model with high pressure setting kit
Pressure Reducing System – Typical Installation
Corp & Actionare: Fonta ductila Interior: Inox
Intern:
Otel Inox, bronz & otel acoperit
Pressure Reducing Valve Diafragma:
Model 720 NBR Nylon fabric-reinforced
Etansare: NBR
Relief Valve
Model 73Q Acoperire: Features and Benefits Major Additional Features
Fusion Bonded Epoxy, RAL 5005 (Blue)
NSF & WRAS approved or Electrostatic
■ Line pressure driven – Independent operation ■ UL Listed for fire protection – FP-720-UL
Polyester Powder, RAL 6017 (Green)
■ In-line serviceable – Easy maintenance ■ Solenoid control – 720-55
How to Order
■ Double chamber design ■ Check valve – 720-20
Please specify the requested valve in the following sequence: (for more options, refer to Ordering Guide)
Strainer ❏ Moderated valve reaction ■ Solenoid control & check valve – 720-25
Model 70F Primary Additional Body End Voltage & Tubing Additonal
Sector Size Feature Feature Pattern Material Connections Coating Position & Fittings Attributes ❑ Protected diaphragm ■ Proportional – 720-PD
■ Flexible design – Easy addition of features ■ Automatic regulation override – 720-09
WW
- 6”
- 720- 00
- -Y -C 16 EB – CB VI
■ Variety of accessories – Perfect mission matching ■ High sensitivity pilot – 720-12
By-Pass ■ ■
Pressure Reducing Valve Waterworks 1 1/2 - 32” Pressure Reducing Oblique (up to 20”) Y Epoxy FB Blue EB Copper Tubing & Brass Fittings CB
"Y" or angle, wide body – Minimized pressure loss Emergency pressure reducing valve – 720-PD-59
Model 720 Angle (up to 18”) A Polyester Green PG Plastic Tubing & Brass Fittings PB ■ Semi-straight flow – Non-turbulent flow ■ Downstream over pressure guard – 720-48
Globe (24-32” only) G Polyester Blue PB St. St. 316 Tubing & Fittings NN
■ Stainless Steel raised seat – Cavitation damage resistant ■ Electrically selected multi-level setting – 720-45
In addition to the Model 720 Pressure Reducing Valve, BERMAD recommends that the system also include: Uncoated UC
Valve Position Indicator I
■ Obstacle free, full bore – Uncompromising reliability ■ Electronic multi-level setting, Type 4T – 720-4T
■ Strainer Model 70F prevents debris from damaging valve operation No Additional Feature 00 Ductile Iron Standard C V-Port Throttling Plug V
■ Relief Valve Model 73Q provides: Closing and Opening Speed Control 03 Cast Steel S Large Control Filter F ■ V-Port Throttling Plug – Low flow stability ■ Electronic pressure reducing valve – 728-03
Automatic Regulation Override 09 St. Steel 316 N Electric Limit Switch S
❏ Protection against momentary pressure peaks
High sensitivity pilot 12 Nickel Alumin. Bronze U 3-Way Control Loop X
❏ Visual indication of need for maintenance Check Valve 20 24VAC/50Hz - N.C. 4AC Valve Position Transmitter Q See relevant BERMAD publications.
Solenoid Controlled & Check Valve 25 ISO-16 16 24VAC/50Hz - N.O. 4AO St. St. 316 Control Accessories N
■ By-Pass Pressure Reducing Valve saves on maintenance costs. The larger (more costly to maintain) valve operates
Multi-Setting Levels - Electrically Selected 45 ISO-25 25 24VDC - N.C. 4DC St. St. 316 Internal Trim (Closure & Seat) T
during peak demand. The smaller by-pass valve cuts operating hours of the larger valve, achieving greater Downstream Over Pressure Guard 48 ANSI-150 A5 24VDC - N.O. 4DO St. St. 316 Actuator Internal Assembly D
return on investment. Hydraulic Control 50 ANSI-300 A3 24VDC - L.P. 4DP Delrin Bearing R
Solenoid Controlled 55 JIS-16 J6 220VAC/50-60Hz N.C. 2AC Viton Elastomers for Seals & Diaphragm E
For high differential pressure systems, see BERMAD publication 720-PD Proportional Pressure Reducing Valve. Electric Override 59 JIS-20 J2 220VAC/50-60Hz N.O. 2AO Pressure Gauge 6
Multiple choices permitted Use when additional electric control Multiple choices permitted
For high pressure systems, see BERMAD publication 820 Piston Actuated Pressure Reducing Valve. feature is selected

info@bermad.com • www.bermad.com
The information herein is subject to change without notice. BERMAD shall not be held liable for
any errors. All rights reserved. © Copyright by BERMAD. PC7WE20 05

You might also like