You are on page 1of 2

PASSIVE 8 - WAY SPLITTER

PSB 100 SAT IF, LNC power supply

PRODUCT VARIANTS
BLINE PSB 100 9061.08 SAT IF Splitter [950 … 2150 MHz]
Voltage display with LNC remote power supply
LNC SUPPLY

SAT - IF
IN

ULNC 15
SAT - TV - Input
(V) 17

OUT 1
13
Voltage selection switch

OUT 2

OUT 3

OUT 4

SAT - TV - Output
OUT 5 GENERAL
OUT 6 The passive SAT - IF - splitter PSB 100 is a module of the head end system B -
Line, which is conceived as a complete system for middle sized distribution
OUT 7
networks.
OUT 8 The module makes the small loss, uncoupled splitting of a SAT IF signal onto 8
outputs possible.
PASSIVE - WAY SPLITTER
LNC REMOTE SUPPLY
MODEL: PSB 100 ART.-No.:9061.08
-
-
SAT-IF-IN / OUT
INSERTION LOSS
LNC SUPPLY
950 … 2150 MHz
12 dB
13 / 15 / 17 V / 0,4 A MAX.
The remote supply of the outside unit with different DC voltages is possible
INPUT POWER 14 W
-
because of the internal power supply.
MAINS 230 VAC

47 ...63 Hz
Power supply
! CAUTION DO NOT OPEN

Fig. 01
FUNCTION DESCRIPTION
The module contains a passive 8 - way splitter in micro strip technology and a remote supply power pack.
The special distribution structure causes an even power partitioning onto all 8 outputs and at the same time takes care of the
necessary mutual uncoupling.
All outputs are capacitive separated and because of that reason DC voltage free.
The integrated power supply unit secures the DC voltage supply of the outside unit (LNC) via the coaxial cable.
Depending on the used LNC - type and / or polarization, it is possible to adjust voltage levels from 13 V, 15 V or 17 V with the installed
switch.
Additional information: Block diagram (Fig. 02)
Adjustment of the LNC supply voltage (Fig. 03)

BLOCK DIAGRAM ADJUSTMENT OF THE LNC SUPPLY VOLTAGE


Please avoid to turn the voltage selection switch over one of the two end
positions!

Power supply

17 V Central : 17 V

15 V

Right : 15 V

Input
~ Left : 13 V

3 Fig. 03
13 V
Outputs
230 V~

~ 50 / 60 Hz

Notice
The connection of the main voltage should generally be done with load!

Before connecting the PSB 100 to the 230 V~ main line the necessary LNC
supply voltage (13 V, 15 V or 17 V) has to be adjusted with the voltage selction
switch.
An internal protection circuit will turn of the LNC supply voltage if there is a no-
load operation or a net over voltage.
The supply current of the LNC will be, in case of a short circuit, limited to ca. 500
Fig. 02 mA.
TECHNICAL DATA
SAT IF
Frequency range 950 ... 2150 MHz
Connector F socket
Impedance 75 W
Through loss 13 dB
Isolation of the outputs ³20 dB

Power supply unit


Main voltage 230 V~, (+10 % / -20 %)
Power socket Built in connector according
to EN 60320 - 1 / C8
(IEC 320 - C8)
Main frequency 50 / 60 Hz
Power consumption max. 14 W
DC voltage (switchable) 13 V / 15 V / 17 V
Current consumption max. 300 mA
Current limit 500 mA
Internal device fuse G 5 x 20,
T100 / 250 (IEC 127)
Protection class II after DIN VDE 0860
Protective system IP 20
Radio noise after DIN VDE 0871
(curve B)

Environmental conditions
Temperature range -10 … +55 oC
Relative humidity £80 % (non condensing)
Mounting method vertical
Mounting location squirting and dripping water
protected

Physical information
Dimensions (l x w x h)
without 19” - adapter 50 x 276 x 148 mm
with 19” - adapter 50 x 301 x 148 mm
Weight 1.485 g

Delivery contents
1 x Power cable

SECURITY AND OPERATING INSTRUCTIONS


When assembling, starting-up and adjusting the modules, it is necessary to consider the system specific references in the
manual instruction!

The modules may only be installed and started up by authorized technical personnel!

When assembling the modules into the receiving points, the adherence of the EMV regulations is to be secured!

The assembly and wiring have to be done without voltage!

All active modules may only be operated with the head end controller HCB 100 or bus extender BEB 100!

The main voltage for all power supply units is 230 V, 50 Hz.

With all work the defaults of the DIN EN 50083 have to be considered!
Especially the safety relevant execution of the DIN EN 50083/1 is necessary!

Part - No.: 9061.08

BLANKOM Antennentechnik GmbH


Hermann - Petersilge - Str. 1 · 07422 Bad Blankenburg · Germany · Phone +49 (0) 36741/ 60-0 · Fax +49 (0) 36741/ 60-100

You might also like