r
Project 1033
SECTION 07 95 oo
EXPANSION CONTROL
r
[ PROJECT IN CO - OPERATION WITH:
•• BURO RAPPOLD
GEOFFREY BARNET ASSOCIATES r----------=-~:~.~-..-
l G LARSENARC::HIT E CTS
SECTION 07 95 oo
EXPANSION CONTROL
PART 1- GENERAL
B.
and Division 01 Specification Sections, apply to this Section.
Descriptive Work:
r
1. Refer to Contractors Design Responsibilities in Section 0110 oo
2.
3.
Complete the Detailed Design, manufacture supply install and warrant the work, complying
with the visual intent indicated and specified design and performance requirements.
Where no material product or supplier is specified, propose suitable materials and systems
r
prior to the Contract Award which comply with the visual intent indicated and specified design
and performance requirements, and be fully responsible for the Design of the Works.
4. Where a particular material, product or supplier is specified, the material, product or supplier
shall be deemed to be indicative representing the Architects Design Intent only. Complete the
installation using the specified or other product acceptable to the Architect, in writing. Be
fully responsible for the Detailed Design and performance of the works. f
1.2 REFERENCE STANDARDS
A. Material and assemblies shall meet or exceed all applicable referenced standards, federal, state and
local requirements, and conform to codes and ordinances of authorities having jurisdiction.
B. The latest published edition of a reference shall be applicable to this Project unless identified by a
specific edition date.
c. All reference amendments adopted prior to the effective date of this Contract shall be applicable to
this Project.
D. All materials, installation and workmanship shall comply with all applicable requirements and
standards.
1.3 SUMMARY
A. Sections Included:
1. Interior Floor Expansion Joint Covers
2. Elastomatic Seal Expansion Joints
B. Related Sections:
1. Section o8 69 oo - Access Flooring
2. Section 09 21 oo- Gypsum Board Assemblies
3. Section 09 22 oo - Support for Plaster and Gypsum Board.
SUBMITTALS
I
A. Comply with Section 01 33 oo - Submittal Procedures.
B. Tender Submittals:
1. Drawings of full extend of the work
2. Product Data on proposed materials
~q.U.a~
KAFD - SKYWALKS Alt,miuium
DATE: 05.05.2010
REV. o: xx.xx.xxxx 2 OF 6
c 1.6
F. Quality benchmark installation: complete one full bay plus one end interface detail and obtain
approval before proceeding with any other installations works
r A.
B.
Comply with Section 01 60 oo - Product Requirements.
Deliver assemblies to project site in manufacturer's clean, unopened cartons or crates.
[ K.AFD- SKYWALKS
DATE: 05.05.2010
REV. o : xx.xx.xxxx 3 OF 6
1.8
A.
WARRANTY
Provide manufacturer's written warranty per Section 01 77 oo - Closeout Procedures.
r
PART 2 - PRODUCTS
r
2.1
A.
GENERAL
All materials shall meet or exceed all applicable referenced standards, federal, state and local
r
requirements, and conform to codes and ordinances of authorities having jurisdiction.
2.2 MANUFACTURERS r
A. Subject to compliance with requirements, provide products from the following manufacturer:
1.
2.
EM SEAL - Westborough, Massachusetts- USA
Silka- Jeddah- Saudi Arabia
r
B. Substitutions: Comply with Section 01 6o oo - Product Requirements.
PERFORMANCE REQUIREMENTS
[
A. Fire Performance Characteristics: Where required, provide expansion joint cover assemblies
identical to those of assemblies whose fire resistance has been determined per ANSI/UL 263, NFPA
251 or ASTM E119, and ASTM E814, including hose stream test at full-rated period by UL.
[
1. Fire Rating: Not less than the rating of adjacent construction.
B. Joint Movement: Design and fabricate Floor expansion joint cover assemblies to permit the following
amount of movement without disengagement or other damage:
r
1. Horizontal: Maximum x-axis joint movement of 10mm.
2.
3.
Vertical: Maximum y-axis joint movement of 1mm.
Lateral: Maximum z-axis joint movement of 1mm.
[
C. Joint Movement: Design and fabricate Bridge expansion joint cover assemblies to permit the
following amount of movement without disengagement or other damage:
1. Horizontal: Maximum x-axis joint movement of 40mm.
[
2. Vertical: Maximum y-axis joint movement of smm.
D.
3. Lateral: Maximum z-axis joint movement of 1mm.
Allowable Loading: Design and fabricate expansion joint cover assemblies to accommodate the
[
following loading without distortion or damage:
1.
2.
Ulitmate Load: 12.00 kN.
Concentrated Load: 6.00 kN. [
3. Maximum Deflection: 1mm.
[
REV. o: xx.xx.xxxx
PART 3 - EXECUTION
3.1 EXAMINATION
A. Verification of Conditions: Examine areas and conditions under which work is to be performed and
identify conditions detrimental to proper and or timely completion.
1. Verify that joint preparation and affected dimensions are acceptable.
2. Confirm that selected expansion joint covers are appropriate for actual joint dimensions.
3. Joint surfaces to receive seal shall be sound, smooth, straight, parallel, clean, dry and free of
all visible contaminants. I
3.2 INSTALLATION
A. Install in accordance with manufacturer's printed installation instructions
KAFD - SKYWALKS
DAT E: 05.05.2010 wI~ uw ?lJ J:! jSV I
N Ghunil" Conrtnu:tioo 0-
REV. o : x x.xx.xxxx 5 OF 6
C.
recommendations.
Protect installed products until completion of project.
r
D.
E.
Touch-up, repair or replace damaged products before Substantial Completion.
Remove and reinstall improperly installed material. r
F. Remove damaged material, or material that cannot be properly repaired, and install new material.
END OF SECTION
!
[
r
[
KAFD - SKYWALKS
DATE: 05.05.2010
REV. o: xx.xx.xxxx 6 OF 6