SIMPLEX

INDOOR PANEL
Wastewater Control Panel
• High Level Alarm
• NEMA1 Enclosure
• Single Phase

APPLICATIONS FEATURES
Superior quality simplex liquid level • High level alarm circuit includes spring
controller, automatically maintains loaded through door-mounted silence
pump operation. High level alarm switch for manual silence of alarm horn.
warning for a variety of sump, effluent, • Through door mounted alarm test switch
sewage and water transfer applications. insures proper operation of the alarm circuit
Not for use in damp, outdoor, or without the need to open the panel.
weatherproof applications.
• Through door mounted pump run light.
• Top mounted high intensity flashing red
SPECIFICATIONS light provides 360° visibility.
• Non-modifiable — No options • Pulsating, corrosion proof alarm horn.
available.
• Color coded wiring, screw type terminals
• Accepts single or dual power feed. and plug in sockets, insure ease of field
• Hand-off-automatic (H-O-A) pump servicing.
selection switch. • Field wiring diagram, panel schematic and
• On-off control circuit switch. installation instructions included.
• Oversized magnetic contactors. • Panel can be wired for a single power feed for pump and control
circuit or the control circuit can be wired to a separate power
• Numbered terminal strip-screw type. supply to insure alarm integrity in case of a tripped pump
• NEMA 1, 30 watt, flashing red light. breaker.
• NEMA 1, steel enclosure. • Auxiliary alarm contacts provided for remote alarm connection.
• NEMA 1, alarm horn – 95db. • Entire unit is UL and CUL listed.
• Auxiliary alarm contacts. • Float Switches – Note: Please order float switches separately.
Single Phase We offer several types and models. See the Float Switch bulletin
for available options. The type selected determines the quantity
• Field adjustable for 115 or 230 V, 60 Hz. needed. The basin depth and panel location determine the
• Enclosure: 8.3" H x 8.3" W x 4.5" D. required cord length. Contact your distributor or Customer
NOTE: Enclosure dimensions do not include 3" high light. Service for additional information.

PANEL MODEL INFORMATION


ORDER NUMBER AMP RANGE
S10020N1 0-20

CentriPro

© 2003 CentriPro
ITT Industries
BCP1-R1
SIMPLEX
INDOOR PANEL
Wastewater Control Panel

115/230 VAC (FOR 115 VAC, USE TERMINALS L1 AND N, JUMP L2 AND N).
SINGLE PHASE, 60 Hz
S1
L1 T1
PUMP
L2 T2

NOTE: WHEN USING SEPARATE 115 VAC CONTROL POWER SUPPLY, REMOVE
GND J1
JUMPER (J1) FROM TERMINALS (L1) AND LL1). CONNECT 15 AMP MAX.
PROTECTED 115 VAC SUPPLY TO TERMINALS (LL1) AND (N) WITH
LL1 THE NEUTRAL OF THE SUPPLY TO (N).

A 230 VOLT SYSTEM CONTROL


REQUIRES A 4 WIRE ON-OFF
POWER SUPPLY LINE
L1, L2, N AND GND.
WITHOUT A NEUTRAL THE
CONTROL CIRCUIT
WILL NOT WORK. RUN

HAND
S1-AUX
OFF
S1

1 2 3 AUTO

OFF FLOAT ON FLOAT

FLASH HIGH
FLASHER

4 R1

R2
ALARM FLOAT R1 HORN

TEST SILENCE

5 6 R2

HIGH LEVEL ALARM R2


DRY CONTACTS
J1

Power, Pump and Float Wiring Terminals

L1 L2 LL1 N 1 2 3 4 5 6 T1 T2

➁ FOR 115 VAC OPERATION,


USE TERMINALS L1 AND N,
JUMP TERMINALS L2 AND N.

R1

DRY CONTACTS

115/230 VAC ➁
ALARM
SINGLE PHASE FLOAT
60 Hz
PUMP
ON FLOAT

OFF FLOAT
CentriPro