Speed Flow Pressure Motor Head Inlet Outlet Solid Fiber
Model
3
r/min m /h MPa KW m mm mm mm mm
G20-1 960 0.8 0.6 0.75 60 25 25 1.5 25
G25-1 960 2 0.6 1.5 60 40 25 2 30
G25-2 960 2 1.2 2.2 120 40 25 2 30
G30-1 960 5 0.6 2.2 60 50 40 2.5 35
G30-2 960 5 1.2 3 120 50 40 2.5 35
G35-1 960 8 0.6 3 60 65 50 3 40
G35-2 960 8 1.2 4 120 65 50 3 40
G40-1 960 12 0.6 4 60 80 65 3.8 45
G40-2 960 12 1.2 5.5 120 80 65 3.8 45
G50-1 720 14 0.6 5.5 60 100 80 5 50
G50-2 720 14 1.2 7.5 120 100 80 5 50
G60-1 720 22 0.6 11 60 125 100 6 60
G60-2 720 22 1.2 15 120 125 100 6 60
G70-1 720 38 0.6 11 60 150 125 8 70
G70-2 720 38 1.2 18.5 120 150 125 8 70
G85-1 630 56 0.6 15 60 150 150 10 80
G105-1 500 100 0.6 30 60 200 200 15 110
G135-1 400 150 0.6 45-3- 60 250 250 20 150

Performance Data
G-Series
speed r/min
Reated 795 630 500 400 315 250 200 160 125 100 80 63
Model of pump Pressure Q P Q P Q P Q P Q P Q P Q P Q P Q P Q P Q P Q P Q P
Mpa m³/h KW m³/h KW m³/h KW m³/h KW m³/h KW m³/h KW m³/h KW m³/h KW m³/h KW m³/h KW m³/h KW m³/h KW m³/h KW
G 015 0-0.6 0.74~0.64 0.37 0.59~0.5 0.37 0.47~0.38 0.25 0.37~0.3 0.25 0.29~0.25 0.18 0.23~0.18 0.18 0.19~0.14 0.18 0.15~0.1 0.18
G 021 0-0.6 1.74~1.5 0.75 1.38~1.2 0.55 1.1~1.0 0.55 0.87~0.7 0.37 0.69~0.6 0.37 0.55~0.4 0.37 0.44~0.3 0.37
G 031 0-0.6 5.23~4.5 1.5 4.18~3.6 1.1 3.32~2.8 1.1 2.64~2.0 0.75 2.1~1.6 0.75 1.66~1.2 0.55 1.32~0.9 0.55
G 038 0-0.6 11.7~10 3 9.3~7.7 2.2 7.38~5.6 2.2 5.86~4.5 1.5 4.66~3.2 1.5 3.7~2.5 1.5 2.94~1.5 1.1
G 045 0-0.6 20.6~18 5.5 16.3~15.5 4 13.3~11.5 4 10.3~9.0 3 8.19~7.0 2.2 6.5~4.0 2.2 5.17~3.0 1.5
G 053 0-0.6 29.1~24 5.5 23.2~18.0 5.5 18.4~14 4 14.6~11 3 11.6~8.0 2.2 9.22~6.0 2.2 7.32~4.5 2.2
G 063 0-0.6 49.2~40.2 11 39.1~31 11 31.0~23 7.5 24.6~18.5 5.5 19.6~12 4 15.6~10 3 12.4~5.0 3
G 076 0-0.6 65.4~54 15 52.0~42 11 41.3~33 11 32.8~25 7.5 26.1~17 5.5 20.7~14 4
G 090 0-0.6 111.0~93 30 88.2~70 22 70.0~53 18.5 55.6~40 15 44.2~35 11 35.1~22 7.5 27.9~15 5.5 -8-
G105 0-0.6 138.4~120 37 109.9~120 30 87.3~67 22 69.3~50 18.5 55.1~37 15 43.8~33 11 34.8~20 11
G125 0-0.6 244.9~216 45 194.5~170 37 154.5~130 30 122.8~100 30 97.5~80 18.5 77.5~62 15 61.5~43 11
G148 0-0.6 411.0~360 57 326.5~280 45 259.3~213 37 206.6~162 30 163.6~124 22 130.6~93 18.5 103.0~56 15

The power in the table indicates that of motor under related pressure .when the max pressure<related one,the matching power of motor can be decreased.
All parameters in the table are water dielectric test data, such as the transmission of high viscosity medium, the power should be improved. Decided by the medium.