2008/10/14 Actuator (Air Conditioner Control) (RENR7298-37)

SMCS - 7320 i03258243

Illustration 1 g01659993
(5) Actuator (air Outlet)
(6) Actuator (air Inlet)
(7) Actuator (air temperature)
The unit for the heater/air conditioner contains three actuators which control the position of air dampers.

When the related switch is operated from the control panel, power is supplied to terminal 6 or 7 of the actuator. The direction of rotation varies
according to the terminal that receives power. Each actuator has a variable resistor. The amount of resistance varies according to the speed of the
actuator. The control panel supplies 5 V voltage to the variable resistor. The control panel detects the position of the damper by measuring the
voltage difference. The control panel then stops the power supply to the actuator when the designated position is detected. The designated position
is set at the control panel.

Note: If power is supplied directly to the actuator, do not drive the actuator. The output shaft of the actuator could be damaged. The winding of the
actuator could break.

Actuator (Air Inlet)

Illustration 2 g01131320

https://sis2.cat.com/#/print-preview/service/%257B%2522title%2522%253A%2522Actuator%2520(Air%2520Conditioner%2520Control)%2520(RENR7298-37)%2522%252C%2522formattedPublicationDate%2522%… 1/2
23/8/22, 16:52 SIS 2.0

(13) Detection switch for fresh air


(14) Detection switch for recirculated air
(15) Contact point for air recirculated air.
(16) Contact point for fresh air
The actuator operates in conjunction with the detection switches. In this case, the detection switch for fresh air and the detection switch for
recirculated air work with the detection switch for the position of the actuator.

For example, when the control switch is changed from fresh air to recirculated air, the contact point moves. As a result, the power supply is
suspended and the contact point stops at the position for fresh air.

Actuator (Air Outlet)

Illustration 3 g01131704
The microcomputer sends signals to the actuator. This changes the discharge positions in order to control the damper position for the following
settings:

FACE

FACE AND FLOOR

FOOT

FOOT AND DEFROST

Air Mix Actuator


The air mix actuator is for the air temperature control. The actuator opens and the actuator closes the air mix door. The air mix actuator has a
potentiometer that connects with the shaft of the actuator.

The target position of the air mix door is determined by the temperature control switch. The potentiometer of the actuator sends data to the control
module. The control module will determine the direction that the actuator will rotate.