3
HYDRA V2
Tank level display
PRESENTATION
The HYDRA V2 is an analogue level display. It is compa-
tible with a large number of standards used in the marine
industry such as 0-10VDC, 4-20mA and resistive probes.
Very simple to install, the HYDRAV2 offers a cost-effective
solution for monitoring the level of liquid in the tanks.
FUNCTIONAL CHARACTERISTICS
Display Functions Options
Calibration, brightness adjustment
Specific pictogram on the front.
and level alarm settings are easily
Resistive sensor connection.
managed by the installer on the
back of the product.
Intuitive light interface.
Simple configuration for input current
or voltage.
Outputs
Alarm or transfer pump control
(depending on the threshold set by
the installer). 0VDC output (500mA
Max) to be wired on a power relay.
Inputs
Voltage from 0 to 10VDC.
Current between 4 and 20mA.
CONNECTION
MECHANICAL CHARACTERISTICS OVERVIEW
Dimensions Weight
(LxlxH)
kg
0.1
Overall :
72.4 x 26.92 x 72.4 mm Mounting
Housing:
Fixed using four stainless
Drilling diameter: 68mm
steel screws provided.
ELECTRICAL CHARACTERISTICS
Power supply Electrical connection
VDC.
24
Connection via a 6
point terminal block,
Consumption 250mA 1,5mm².
Max. excluding the
alarm output.
Electrical protections
Reverse polarity power
supply protection.
Signal input protected
by resettable fuse.
Alarm output protected
by a 500mA SMD fuse
ENVIRONMENTAL
non resettable. CONDITIONS
Temperature limits
0°C to 55°C (functioning)
0°C to 70°C (storage)
Humidity
95% Humidity max.
Protection rating
IP
IP44
REFERENCES
& OPTIONS
Rédigé par MOB, 07/12/17 - Approuvé par JMA, 22/11/18 HYDRA V2 DS GB REV 0 / Document non contractuel
HYDRA P
Tank level display
PRESENTATION
HYDRA P offers a cost-effective solution for monitoring the
level of liquid in the tanks with linear & non-linear signal
The Bar graph + digital display reinforced by a backlight
animation ensure a perfect lisibility
Thanks to a user-friendly software, it is fully customizable
(identification, brightness & color display, scale, alarm
threshold, etc ...)
Finally, it can also be used as a display for other on-board
processes (pressure, temperature, etc...)
FUNCTIONAL CHARACTERISTICS
Functions Display Inputs
Customizable annunciators
Multi-functional display with: 1 input signal which can be:
Display Range: - Customizable text on 4 characters Voltage : 0 to +/-10VDC, 100KΩ
1
communication)
CONNECTION
MECHANICAL CHARACTERISTICS OVERVIEW
Dimensions Weight
(HxLxD in mm)
0.180 kg
Overall :
72 x 72 x 53 Mounting
Cutout:
Flush mounted with 2
68 x 68 (H x L)
clamping screws on the back
Max. panel/console thickness:
10 mm
ELECTRICAL CHARACTERISTICS
Power supply Electrical connection
12-24Vdc
Connection via a 10
point terminal blocks,
1.5mm².
Consumption
Consumption XX mA
Max. excluding the
alarm output.
ENVIRONMENTAL
CONDITIONS
Temperature limits
-10°C to 60°C (functioning)
- 40°C to 70°C (storage)
Humidity
REFERENCES
85% humidity max.
& OPTIONS Protection rating
IP
IP65 (front face)
HYDRA_P_F: Level display, dark background
HYDRA_P_C: Level display , bright background (in option)
HYDRA_P_KITPROG: programming kit, Software + USB 2.0 type A /B cable, 3m
Rédigé par MOB, 21/03/22 - Approuvé par JMA, HYDRA P DS GB REV 0 / Document non contractuel
ALTO
Configurable 4 channel alarm panel
PRESENTATION
fAlarm panel with 4 channels providing light and sound
signaling for all types of senors A.O.N. (all or nothing)
particularly those intended for flood and fire detection.
f9-32 VDC power supply.
fLine monitoring.
fBlinking LEDs to identify unacknowledged alarms.
fCustomizable labels to identify the channels.
FUNCTIONAL CHARACTERISTICS
Display Functions Outputs
Dimensions
Installation
(LxWxH)
Console mounting panel
L x l x H:
110 x 110 x 57 mm
(hors-tout)
Weight
0.4Kg
ELECTRICAL CHARACTERISTICS
Electrical connections
Pluggable terminal
blocks,
capacity 1,5 mm²
ENVIRONMENTAL
CONDITIONS
Temperature limits
REFERENCES
-15°C to 70°C (storage)
+5° C to 55°C (functioning)
& OPTIONS
Humidity
Wall mounted housing and cable
glands.
95% Humidity max.
Protection rating
IP (front panel)
f44
Rédigé par MOB, 25/06/18 - Approuvé par JMA, 22/11/18 ALTO DS GB REV 0 / Document non contractuel
MACCS 8L
Water ingress detection
PRESENTATION
MACCS_8L, is a safety device capable of monitoring 1 to
8 water level detectors (MARINELEC reference:
VIGIFLO_B_SL).
The product is designed to ensure reliable and secure
water ingress detection on small to medium sized vessels.
FUNCTIONAL CHARACTERISTICS
Equipment presentation MACCS_CPU Functions
MACCS 8L is a device designed
Central processor of the system
Configuration by microswitches
to detect and signal water ingress ensuring the management of power located at the back of MACCS_LED
alarms on vessels. supplies and input channels.
Management of 2 power sources
The product is composed of a
Management of the 2 power sources 9-32VDC with alarm
compact visual and sound signalling (main / emergency).
Configurable parameters
panel (MACCS_LED) and an 8
Direct connection to MACCS_LED according to the chosen
channel acquisition card via 3m CAT6 network cable supplied
configuration :
(MACCS_CPU). (24VDC power supply + RS485
signals) • Normally Open /
offers a quick set up and very
It Normally Closed
8 inputs for water level detectors with
simple and intuitive use, without line monitoring, VIGIFLO_B_SL type
• With monitoring
programming. (not included in delivery)
(MMF obligation) / Without line
1 output powered 24V/0.5A to monitoring
control visual and audible alarm
devices.
Time delay 0/10/20/30s
Faults alarm buzzer
Distinction between acknowledged
and unacknowledged alarms
Detection of short circuits and
MACCS_LED detection line breaks (MACCS_LED)
Mounting
MACCS_LED: Built-in mounting in console / cabinet
MACCS_CPU: Symmetrical DIN rail mounting
ELECTRICAL CHARACTERISTICS
Main power supply Emergency power
supply
VDC / 24 VDC
12
(-25% +30%), 1A max VDC / 24 VDC
12
(-25% +30%), 1A max
MACCS_LED :
Power supply output
0.5A @24 VDC 24VDC : 1A ENVIRONMENTAL
MACCS_CPU
1A @24VDC
:
Audible and luminous
alarm outputs: 0.5A
CONDITIONS
Temperature limits
Connection
+5°C à 55°C (functioning)
Coded pluggable
0°C à 70°C (storage)
terminal blocks (MACCS_
CPU) Humidity
Cable max. section
95% Humidity max.
1,5mm² (power supplies)
1mm² (inputs-outputs) Protection rating
Network cable RJ45
provided (3m) IP
MACCS_LED: IP44
MACCS_CPU: IP20
REFERENCES
& OPTIONS
SR24_1HE: Multitone red siren 110dB, red base IP66
Conventional fire detector (not approved): please contact us.
Rédigé par MOB, 14/12/20 - Approuvé par JMA, 14/12/20 MACCS_8L DS GB REV 1 / Document non contractuel
VIGIFLO_B
Water ingress detection
PRESENTATION
VIGIFLO level detectors provide detection of water ingress
onboard ships.
We offer products with line monitoring VIGIFLO_B_SL or
without line monitoring VIGIFLO_B.
Integral protection of the float against risks of blockages
and mechanical shocks.
Integrated test rod for quick test.
Small footprint.
FUNCTIONAL CHARACTERISTICS
VIGIFLO_B VIGIFLO_B_SL
Simple interface to alarm panel or
Simple interface to alarm panel.
alarm monitoring system.
Particularly suitable for monitoring
Particularly suitable for monitoring flooding in holds (engine room,
flooding in holds (engine room, wheelhouse, forepeak, cooler, etc.).
wheelhouse, forepeak, cooler, etc.).
Integrated online monitoring
Approved by the BV. functionality.
Approved by the BV and MMF.
APPROVALS
Bureau Veritas
MMF (Division 361, Edition 2018)
CONNECTION
MECHANICAL CHARACTERISTICS OVERVIEW
Dimensions Material
diagram
see
stainless steel
Weights
180 g
Cable
length 5m, 2x075mm²
ELECTRICAL CHARACTERISTICS
Electrical connection Electrical connection
VIGIFLO_B VIGIFLO_B_SL
ENVIRONMENTAL
CONDITIONS
Temperature limits
REFERENCES
-20°C to 70°C
Rédigé par MOB, 26/03/18 - Approuvé par JMA, VIGIFLO_B DS FGB REV 0 / Document non contractuel
MACCS
Alarm and monitoring system
PRESENTATION
MACCS is a safety device used for monitoring digital
inputs and analog inputs, as well as the controlling of
various equipment.
FUNCTIONAL CHARACTERISTICS
Display MACCS_CPU MACCS_HMI
MACCS is a modular system with up 2 x RS485 ports to communicate
Protected menu of 1st level settings:
with external equipment (NMEA channel assignment, input /
to 64 inputs/outputs, composed of a CPU or MODBUS RTU, other protocols on output types, time delay.
module (MACCS_CPU) with 8 digital request)
inputs and up to 7 expansion modules 8 monitored digital inputs and 1
configurable digital input (special MACCS_8DI
(up to 2 if the power supply is 12VDC).
functions including
Allowing the capacity of each product to acknowledgement). digital inputs :
8
be extended according to the needs of 5 integrated outputs (1 x 24VDC + Monitored or not.
the ship, through additional digital/ana- 4 x digital). Configurable N.O./N.C.
log inputs and digital outputs. Time delay from 0 to 180s
in 1 second increments.
MACCS_8DO Individual inhibition per channel.
digital outputs :
8
MACCS_8AI
Breaking capacity1A@24VDC.
Contacts N.O. and N.C provided.
analog inputs :
8 Time delay form 0 to 180s in 1
Input 0/10VDC or 4/20mA
(2 or 3 wires).
second increments. APPROVALS
Operation in mode Maintained or Bureau Veritas
Time delay from 0 to 180s Impulse.
1 second increments. MMF
Emergency manual activation by
4 x alarm thresholds per channel. micro switches.
Calibration with 21 values.
CONNECTION
MECHANICAL CHARACTERISTICS OVERVIEW
ELECTRICAL CHARACTERISTICS
Main power supply Emergency power
supply
- 32 VDC
9
- 32 VDC
9
MACCS_HMI : 0.5A
MACCS_HMI : 0.3A
MACCS_CPU : 0.25A
MACCS_CPU : 0.2 A
MACCS_8DI : 0.22A
MACCS_8DI : 0.11A
ENVIRONMENTAL
MACCS_8AI : 0.5A
MACCS_8AI : 0.3A CONDITIONS
MACCS_8DO : 0.22A
MACCS_8DO : 0.1A
Temperature limits
+5°C to 55°C (functioning)
Connections Output capacity
0°C to 70°C (storage)
Coded pluggable
Power supply output Humidity
terminal blocks (CPU) : 3A
95% Humidity max.
Max.section cable
24VDC outputs
1,5mm² (power supplies) (CPU and HMI) : 0.5A Ingress protection rating
1mm² (inputs-outputs)
Digital outputs (CPU and
_8DO) : 1A @24VDC
IP
MACCS_HMI: IP66 MACCS_8XX : IP20
MACCS_CPU: IP20
REFERENCES
MACCS_HMI
MACCS_HMI_10P
7’’color touch screen interface
10’’color touch screen interface
& OPTIONS
MACCS_CPU Processor module
MACCS_8DI 8 digital inputs expansion module.
MACCS_8AI 8 analog inputs expansion module
MACCS_8DO 8 digital outputs expansion module.
Optional references are available to enable a quick and complete installation:
(audible and luminous devices, bilge sensors, fire detectors (not approved), level…)
Please contact us
Rédigé par MOB, 14/12/20 - Approuvé par JMA, 14/12/20 MACCS DS GB REV 2 / Document non contractuel
M.TASK
Alarm and monitoring system
PRESENTATION
M.TASK is the powerful Marinelec Integrated Alarm,
Control & Monitoring System.
Scalable modular system
Reliable & secure access
Modern & intuitive interface
Analysis assistance
Customizable (functions, mimic, language)
FUNCTIONAL CHARACTERISTICS
Main functions Marinelec tools I/O interface
Alarm monitoring (bilge, doors,
Curves
Digital inputs & outputs
engine, etc...)
Hour counters
Analog inputs (0/10V, -/+10V,
Tank level measurement
Alarm & page printing 0/20mA, 4/20mA, PT100/1000,
Remote control (lighting, pumps, thermocouple)
Data selection for VDR
valves, fans, etc...)
Analog outputs (0/10 V, -/+10V,
Remote alarm transmitter (sms/
Engine watch alarm management email) 0/20mA, 4/20mA)
Duty officer alarm management
Navigation light control
Web viewer A large range of industrial
communication protocols to interface
detection monitoring
Fire
Secure remote support with embedded systems:
Emergency order telegraph
Data shore analysis «Ecomer TC» Navigation network over
NMEA0183 or NMEA2000
Engines over J1939
Power management system over
Modbus RTU or Modbus TCP
Battery management system over
Advanced functions
CANopen
ETC...
Analytic Econometer «Ecomer»
Conning
Battery management system
Power management system
APPROVALS
Video management Meets all maritime standards
DESIGN OVERVIEW
M.TASK SOFTWARE
REFERENCES
Rédigé par MOB, 01/10/20 - Approuvé par JMA, MTASK DS GB REV 1 / Document non contractuel
FIRE
DETECTION
3
PHILAE
Conventional fire detection
4 to 28 zones
PRESENTATION
PHILAE is a conventional fire detection system with
4 to 28 zones.
PHILAE consists of a basic panel to which up to 3 PHILAE_EM
extension modules can be connected, each with 8 zones.
This gives a maximum capacity of 28 zones.
You can connect up to 32 devices per zone (manual call points,
optical smoke, heat, flame detectors in standard version or
intrinsically safe).
Simple, modular, quick and intuitive installation and
operation.
FUNCTIONAL CHARACTERISTICS
Display Functions Outputs
APPROVALS
M.E.D
CONNECTION
MECHANICAL CHARACTERISTICS OVERVIEW
ELECTRICAL CHARACTERISTICS
Power supply Main power supply
switching
24Vdc (+30%,-25%).
Automatic.
Shielded twisted pair
24Vdc (+30%,-25%).
cable with a minmum
cross-section of
0.75mm².
Consumption
Cable length max. per
zone : 200 m.
PHILAE : 1,25 A max.
120 mA max. per zone.
at 24VDC. ENVIRONMENTAL
Protection of each
zone by resettable
PHILAE_EM : 1,5A CONDITIONS
max. at 24VDC.
fuse.
5,75 A max. for the
complete system at Temperature limits
24VDC.
-15°C à 70°C (storage)
PHILAE_RP: 0.25 A
+5° C à 55°C (functioning)
Humidity
95% RH - non condensable at 55°C
Protection rating
IP
IP32 (front panel)
REFERENCES
PHILAE: Fire detection panel 4 zones
& OPTIONS PHILAE_EM: 8 zones extension module
PHILAE_RP: Repeater on 4" screen
preliminary documentation Rédigé par MOB, 07/01/21 - Approuvé par JMA, 2021 PHILAE DS GB REV 3 / Document non
FIRE DETECTION
Conventional devices
Heat detector
Optical smoke detector
(to be combined with the base EMBCAO). Multisensor detector
(to be combined with the base EMBCAO).
Available in 50°C, 65°C, 80°C. (to be combined with the base EMBCAO)
Flame detector delivered with base and
mounting bracket. Base for conventional detector. Watertight kit for TOA, TTA, TMCA.
Optical smoke detector Heat detector
(to be combined with the base EMBCD). Base for detector TOD and TTD.
(to be combined with the base EMBCD).
TMEXA EMBCEXA
APPROVAL
MED
Intrinsically safe multisensor detector. Base for intrinsically safe detector.
MANUAL CALL POINTS
DMA DME DMEXEA
Indoor manual call point IP24D. Waterproof manual call point IP67. Intrinsically safe manual call point IP67.
Multi-tone red siren, 24VDC, 100dB, IP65, Multi-tone red sounder/beacon 24 VDC ,
MED. 1J, 100dB, IP65, MED.
OTHER
DIAR01 IGEXCONV IAA
Galvanic isolator for intrinsically safe
Multisensor detector with relay base. detector (to be combined with TOEXA, Remote indicator not waterproof.
TTEXA, DMEXEA).
SIRRAH TEMPO
Conventional loop detector timer delay.
Rédigé par MOB, 16/02/21 - Approuvé par JMA, ACC CONV DS GB REV 1 / Document non contractuel
PHOENIX V2
Addressable fire detection
PRESENTATION
The PHOENIX V2 is a 24VDC fire detection panel with a total capacity of 252
addressable points, in its basic version, spread over 2 loops.
Each panel can be used as a fire detection panel or as a simple repeater panel.
The «Cause & Effects» function allows you to configure the functioning of the
devices such as sirens, flashes, input / output modules ... thanks to an
intuitive PC software.
Multiple connections to external equipment such as VDR, AMS, General Alarm and
Public Address can be easily added via digital or RS485 interfaces.
FUNCTIONAL CHARACTERISTICS
Display Functions Loops capacity
Dimensions Weight
(LxlxH)
0.6Kg
Panel : Mounting
172 x 170 x 68 mm
Flush mounting
Front :
Wall mounting
172 x 170 x 23 mm (kit in option).
Housing : Material
145 x 135 mm
ABS
ELECTRICAL CHARACTERISTICS
Main power supply Loops
Integrated, automatic.
ENVIRONMENTAL
Consumption Network
CONDITIONS
2,5A max. The networking of the fire
detection system is done
through a redundant ring. Temperature limits
0,2A in standby mode.
The network can be
-10°C to 70°C (storage)
composed of up to :
5°C at 70°C (functioning)
5 PHOENIX_V2 (252
Comunication points per PHOENIX_V2)
Humidity
3 serial ports RS485 3 PHOENIX_V2_EM
(252 points per
95% max. at 40°C
to comunicate with
PHOENIX_V2_EM)
external equipment
Protection rating
(AMS, VDR, extinguishing
system..) or for
PHOENIX_V2_RP
2
IP 44 (front panel)
IP
OR
networking several
PHOENIX_V2 panels. PHOENIX_V2
8
Available protocols: PHOENIX_V2_RP
2 REFERENCES
NMEA 0183 (IEC
61162-2) / Modbus & OPTIONS
RTU slave. PHOENIX_V2_RP : Remote panel
PHOENIX_V2_EM : 2 lopps expansion module
PHOENIX_TEMPO : Timer delay for loop detector
COF WFCQ : Wall fixing kit for PHOENIX.
PHOENIX_SOFT V2 : PC programing software
CONV RS485 USB : Converter RS485 – USB
PHOENIX MONITOR : Monitoring software
Rédigé par MOB, 26/06/18 - Approuvé par JMA, 22/11/18 PHOENIX V2 DS GB REV 0 / Document non contractuel
PHOENIX MONITOR
Addressable fire detection
PRESENTATION
Phoenix Monitor is a software developed by MARINELEC
that combines with the Phoenix V2 fire detection panel
to provide an ergonomic graphical interface for the
ship’s fire detection system.
Fully customizable by the user
Clear and visual display of any event
Faster decision making & intervention
Event log for analysis
FUNCTIONAL CHARACTERISTICS
Hardware configuration Software configuration User interface
REFERENCES
ET OPTIONS
fLICHW_PHOENIXMONI : PHOENIX MONITOR License
Rédigé par MOB, 10/11/20 - Approuvé par JMA, PHOENIX MONITOR DS GB REV 0 / Document non contractuel
FIRE DETECTION
Addressable devices
Optical smoke detector Heat detector Multisensor detector
(to be combined with the base EMADR). (to be combined with the base EMADR). (to be combined with the base EMADR)
Available in 50°C, 65°C, 80°C.
Flame detector delivered with base and
mounting bracket. Base for addressable detector. Watertight kit for TOADR, TTADR, TMCADR.
EMBISADRW EMBISADRFSW
Isolating base. Sounder & beacon addressable base with
isolator.
Intrinsically safe heat detector. Base for intrinsically safe detector. Intrinsically safe optical smoke detector.
APPROVALS
MED
MANUAL CALL POINTS
DMADRIW DMADREIW DMEXADRE
Manual call point with isolator IP24D. Waterproof manual call point with isolator Intrinsically safe manual call point IP67.
IP67.
Multi-tone red siren, 24VDC, 100dB, IP65, Multi-tone red sounder/beacon 24 VDC ,
MED. 1J, 100dB, IP65, MED.
OTHER
DMZI DIN IGEXADR DPTEXADR
Galvanic isolator for intrinsically safe
Conventional zone monitor for addressable detector (to be combined with TOEXADR, Single channel IS protocol translator .
loop. TTEXADR, DMEXADRE1).
Double short-circuit isolator. Input/output module. Timer module on addressable
loop.
Rédigé par MOB, 15/02/21 - Approuvé par JMA, ACC ADRESS DS GB REV 1 / Document non contractuel
FIRE DETECTION
Test equipment
POLES
TESTPERCHE2.5 TESTPERCHE4.5 TESTEXTPERCHE1.2
Telescopic access pole 2,5 m. Telescopic access pole 4,5 m. Extension pole 1,2 m.
(closed length 1,2 m) (closed length 1,3m)
TESTING KIT
TESTKITDT2.5 TESTKITDF3 TESTKITDF4.5
MISCELLANEOUS
TESTOUTILDEMONTAGE TESTHOUSE
Rédigé par MOB, 11/01/18 - Approuvé par JMA, EQUI TEST DI DS GB REV 0 / Document non contractuel
NAVIGATION LIGHT
MANAGEMENT
3
NORMA.CP
Navigation lights monitoring and
control system
PRESENTATION
NORMA is a navigation lights alarm system. It allows the monitoring
and control of up to 14 24VDC/230VAC navigation lights with a power
ranging from 0.5W to 65W*.
FUNCTIONAL CHARACTERISTICS
Functions NORMA CPU inputs NORMA CPU serial outputs
Power supply: manual or automatic 1 control power supply (24VDC).
NORMA.CP control panel output
switchover with alarm. (RJ45): RS485, 9600 bauds, 8 bits,
1 acknowledgement input ( N.O. 1 stop bit; Modbus RTU
Bipolar protection and control of
navigation lights. (No common wire push button).
VDR (Voyage Data Recorder) output :
authorized). dimming input (N.O.push button).
1 RS485, 4800 bauds, 8 bits,
Compatible with filament or LED test input (N.O.push button).
1 1 stop bit; IEC61162-1
navigation lights under 24 VDC, local/remote switch input.
1
AMS(Alarm Monitoring System) output:
230VAC ( I min./max. see manual ),
ON/OFF switch input.
1 RS485, 9600 bauds, 8 bits,
other voltages available as option.
main/emergency switch input.
1 1 stop bit; Modbus RTU
Lifetime alarm for LEDs navigation
lights. 8 navigation lights control inputs.
Detection of navigation lights failures:
filament breakage, short-circuit,
power supply failure and fuse failure.
NORMA CPU outputs
Day/night mode
Serial connections to control panel,
navigation lights outputs.
8
AMS, VDR.
to14 navigation lights
Up navigation light status indication
8
(230VAC and/or 24VDC, outputs.
2 NORMA.CPU cards needed). 3 relay outputs (buzzer, navigation
Emergency control switches directly light fault, power supply fault)
on the board. (N.O. 24VDC /1A).
1 «system fault» relay output
(N.C. 24VDC/1A).
APPROVALS
4 signalling outputs (power suplies + Bureau Veritas
lifetime alarm).
CONNECTION
MECHANICAL CHARACTERISTICS OVERVIEW
ELECTRICAL CHARACTERISTICS
NORMA.PWR NORMA.CP
Control supply voltage:
Power : 24VCC
24VDC -25%/+30% -25% +30% (Via the
(1A max.) NORMA.CPU card)
Power supply voltage :
Consumption : 0.5A
24VDC -25%/+ 30%
230VAC + -10%, 50-60Hz
Connection to the
(*other voltage, contact us) NORMA.CPU via a
single standard CAT5
Power supply current Ethernet cable, straight,
consumption : 3m (supplied).
30A maximum if
switching directly to the
NORMA.CPU_DC card NORMA.CPU DC
10A maximum if
switching directly to the
Limitation of 200W by
NORMA.CPU_AC card NORMA.CPU (e.g. 5
lights of 40W or 8 lights
ENVIRONMENTAL
of 25W) CONDITIONS
Temperature limits
0°C to 55°C (functioning)
0°C to 70°C (storage)
Humidity
95% Humidity max.
Rédigé par MOB, 30/11/22 - Approuvé par JMA, 30/11/22 NORMA CP DS GB REV 2 / Document non contractuel
NORMA.SYN
Navigation lights monitoring
and control system
PRESENTATION
NORMA is a navigation lights alarm system. It allows the
monitoring and control of up to 48 24VDC/230VAC naviga-
tion lights with a power ranging from 0.5W to 65W*.
The navigation lights are controlled by a NORMA.SYN
synoptic which must be associated with NORMA.CPU and
NORMA.PWR.
NORMA.CPU enables the control and monitoring of 8
navigation lights.
NORMA.PWR provides power management from 2
different sources, with associated alarms, automatic and
manual switchover.
(*65W max. at 230VAC, 40W max. at 24VDC)
FUNCTIONAL CHARACTERISTICS
Functions NORMA CPU inputs NORMA CPU serial outputs
Power supply: manual or automatic 1 control power supply (24VDC).
NORMA.CP control panel output
switchover with alarm. (RJ45): RS485, 9600 bauds, 8 bits,
1 acknowledgement input ( N.O. 1 stop bit; Modbus RTU
Bipolar protection and control of
navigation lights. (No common wire push button).
VDR (Voyage Data Recorder) output :
authorized) dimming input (N.O.push button).
1 RS485, 4800 bauds, 8 bits,
Compatible with filament or LED test input (N.O.push button).
1 1 stop bit; IEC61162-1
navigation lights under 24 VDC, local/remote switch input.
1
AMS(Alarm Monitoring System) output:
230VAC ( I min./max. see manual ),
ON/OFF switch input.
1 RS485, 9600 bauds, 8 bits,
other voltages available as option.
main/emergency switch input.
1 1 stop bit; Modbus RTU
Lifetime alarm for LEDs navigation
lights. 8 navigation lights control inputs.
Detection of navigation lights failures:
filament breakage, short-circuit,
power supply failure and fuse failure.
NORMA CPU outputs
Integrated dimmer for mimic panels.
Serial connections to control panel,
navigation lights outputs.
8
AMS, VDR.
navigation light status indication
8
to 48 navigation lights
Up
outputs.
(up to 6 NORMA.CPU)
3 relay outputs (buzzer, navigation
Emergency control switches directly
light fault, power supply fault)
on the board.
(N.O. 24VDC /1A).
1 «system fault» relay output
(N.C. 24VDC/1A).
APPROVALS
4 signalling outputs (power suplies + Bureau Veritas
lifetime alarm).
CONNECTION
MECHANICAL CHARACTERISTICS OVERVIEW
Dimensions Weight Mounting
ELECTRICAL CHARACTERISTICS
NORMA.PWR NORMA.CPU DC
Control supply voltage:
Limitation of 200W by
24VDC -25%/+30% NORMA.CPU (e.g. 5 lights of
(1A max.) 40W or 8 lights of 25W)
Power supply voltage :
24VDC -25%/+ 30%
230VAC + -10%, 50-60Hz
(*other voltage, contact us)
Power supply current
consumption :
30A maximum if
switching directly to the
NORMA.CPU_DC card
10A maximum if
switching directly to the
NORMA.CPU_AC card ENVIRONMENTAL
CONDITIONS
Temperature limits
0°C to 55°C (functioning)
0°C to 70°C (storage)
Humidity
95% Humidity max.
Rédigé par MOB, 30/11/22 - Approuvé par JMA, 30/11/22 NORMA SYN DS GB REV 2 / Document non contractuel
NORMA.AFF
Navigation lights monitoring and
control system
PRESENTATION
NORMA is a navigation lights alarm system. It allows the
monitoring and control of up to 48 24VDC/230VAC naviga-
tion lights with a power ranging from 0.5W to 65W*.
The navigation lights are controlled by a NORMA.AFF
touchscreen which must be associated with NORMA.CPU
and NORMA.PWR.
NORMA.CPU enables the control and monitoring of 8
navigation lights.
NORMA.PWR provides power management from 2
different sources, with associated alarms, automatic and
manual switchover.
NORMA.AFF has an integrated software allowing you to
customize your interface (ship silhouette, control buttons,
status lights, etc.).
(*65W max. at 230VAC, 40W max. at 24VDC)
FUNCTIONAL CHARACTERISTICS
Functions NORMA CPU inputs NORMA CPU serial outputs
Power supply: manual or automatic control power supply (24VDC).
1
NORMA.CP control panel output
switchover with alarm. (RJ45): RS485, 9600 bauds, 8 bits,
1 acknowledgement input ( N.O.
push button). 1 stop bit; Modbus RTU
Bipolar protection and control of
navigation lights. (No common wire dimming input (N.O.push button).
1
VDR (Voyage Data Recorder) output :
authorized). RS485, 4800 bauds, 8 bits,
test input (N.O.push button).
1
Compatible with filament or LED 1 stop bit; IEC61162-1
local/remote switch input.
1
navigation lights under 24 VDC,
ON/OFF switch input.
1
AMS(Alarm Monitoring System) output:
230VAC ( I min./max. see manual ),
RS485, 9600 bauds, 8 bits,
other voltages available as option. main/emergency switch input.
1
1 stop bit; Modbus RTU
Lifetime alarm for LEDs navigation 8 navigation lights control inputs.
lights.
Detection of navigation lights failures: Software tool NORMA AFF
filament breakage, short-circuit,
power supply failure and fuse failure.
Creation of your lights (mode of
NORMA CPU outputs operation, color, size, location)
Day/ night mode
Serial connections to control panel,
Creation of up to 8 (6*) grouped
navigation lights outputs.
8 controls of 8 lights
AMS, VDR.
navigation light status indication
8
to 48 (24*) navigation lights
Up
Creation of your ship silhouette (import
outputs.
(up to 6 NORMA.CPU) image, size, location)
3 relay outputs (buzzer, navigation
Emergency control switches directly
Library of predefined silhouettes
light fault, power supply fault)
on the board.
(N.O. 24VDC /1A).
Import your silhouette via USB key
1 «system fault» relay output
Export/Import of the panel
(N.C. 24VDC/1A).
*Limitation with a 7’’ touch screen configuration for sistership duplication
4 signalling outputs (power suplies +
lifetime alarm).
APPROBATIONS
Bureau Veritas
CONNECTION
MECHANICAL CHARACTERISTICS OVERVIEW
Dimensions weight Mounting
ELECTRICAL CHARACTERISTICS
NORMA.PWR NORMA.CPU DC
Control supply voltage:
Limitation of 200W by
24VDC -25%/+30% NORMA.CPU (e.g. 5 lights of
(1A max.) 40W or 8 lights of 25W)
Power supply voltage :
24VDC -25%/+ 30%
230VAC + -10%, 50-60Hz
(*other voltage, contact us)
NORMA.AFF
Power supply current
consumption : Consumption :
30A maximum if
switching directly to the 7’’: 24 VDC 0,3 A
NORMA.CPU_DC card
10’’: 24 VDC 0,38 A
10A maximum if
15’’: 24VDC 1,2 A
switching directly to the
21’’: 24VDC 1,7 A
NORMA.CPU_AC card (via NORMA.CPU card) ENVIRONMENTAL
CONDITIONS
Temperature limits
0°C to 55°C (functioning)
0°C to 70°C (storage)
Humidity
95% Humidity max.
Rédigé par MOB, 30/11/22 - Approuvé par JMA, 30/11/22 NORMA AFF DS GB REV 4 / Document non contractuel
SAFETY
SIGNALING
3
AVAS
Audio visual alarm
sequencer
PRESENTATION
The AVAS system is an audible and visual alarm
sequencer which functions are:
General alarm
Control of whistle and foghorn
Management of signals from and to Public
Address System
AVAS is designed and Bureau Veritas approved to
ensure the perfect management of the ship’s audible
and visual signals.
AVAS system can be extended with addional functions
to control light columns (AVASXM).
FUNCTIONAL CHARACTERISTICS
Display AVAS_CPU AVAS inputs
Control of the general alarm signal touch screen display + HB option
7’’
(7 short-1 long)
Integrated overview and quick function
buttons.
Control of a manual call.
Light dimming + day/night mode
Management of signals from and to
Multi-language display (French,
the «Public address system». English, Spanish).
Protected menu for setting up
Whistle sequencer with one integrated I/O: channel assignment,
customizable signal. input/output types. APPROVALS
Bureau Veritas
ELECTRICAL CHARACTERISTICS
Main power supply Emergency power
supply
- 32 VDC
9
- 32 VDC
9
AVAS_HMI : 0.5A
AVAS_HMI : 0.3A
AVAS_CPU : 0.25A
AVAS_CPU : 0.2 A
AVAS_HMI_HB: 1.4A
AVAS_HMI_HB: 0.7A
ENVIRONMENTAL
CONDITIONS
Temperature limits
Connections Output capacity
+5°C to 55°C (functioning)
Coded pluggable
Power supply output
0°C to 70°C (storage)
terminal blocks (CPU) : 3A
Humidity
Max.section cable
24VDC output
1,5mm² (power supplies) (CPU and HMI) : 0.5A
95% Humidity max.
1mm² (inputs-outputs) Ingress protection rating
Digital outputs (CPU):
1A @24VDC
IP
AVAS_HMI: IP66 (front)
IP20 (back)
REFERENCES
AVAS_HMI
AVAS_HMI_HB
7’’color touch screen interface (Supplied with 3m cable for quick connection to AVAS_CPU)
7’’ high brightness colour touchscreen interface
& OPTIONS
AVAS_CPU Processor module
Optional references are available to enable a quick and complete installation:
(audible and visual devices, light columns,sounder beacon, sirens,…)
Rédigé par MOB, 19/02/20 - Approuvé par JMA, AVAS DS GB REV 2 / Document non contractuel
AVASXM
Audio visual alarm
sequencer
PRESENTATION
AVASXM is an audible and visual alarm sequencer
which functions are:
General alarm
Control of whistle and foghorn
Management of signals from and to
Public Address System
Control of alarm light columns
ECR repeater mode
7’’ color touchscreen user interface enables a clear and
Its
precise display of the control functions.
AVAS is designed and Bureau Veritas approved to ensure the
Wheelhouse mode perfect management of the ship’s audible and visual signals.
FUNCTIONAL CHARACTERISTICS
Display Functions AVAS_HMI
ELECTRICAL CHARACTERISTICS
Main power supply Emergency power
supply
- 32 VDC
9
- 32 VDC
9
AVAS_HMI : 0.5A
AVAS_HMI : 0.3A
AVAS_CPU : 0.25A
AVAS_CPU : 0.2 A
AVAS_8DI : 0.22A
AVAS_8DI : 0.11A
ENVIRONMENTAL
AVAS_8DO : 0.22A
AVAS_8DO : 0.1A CONDITIONS
AVAS_HMI_HB: 1.4A
AVAS_HMI_HB: 0.7A
Temperature limits
+5°C to 55°C (functioning)
Connections Output capacity
0°C to 70°C (storage)
Coded pluggable
Power supply output Humidity
terminal blocks (CPU) : 3A
95% Humidity max.
Max.section cable
24VDC output
1,5mm² (power supplies) (CPU and HMI) : 0.5A Ingress protection rating
1mm² (inputs-outputs)
Digital outputs (CPU and
_8DO) : 1A @24VDC
IP
AVAS_HMI: IP66 (front)
IP20 (back)
REFERENCES
AVAS_HMI
AVAS_HMI_HB
7’’color touch screen interface (Supplied with 3m cable for quick connection to AVAS_CPU)
7’’ high brightness colour touchscreen interface
& OPTIONS
AVAS_CPU Processor module
AVAS_8DI 8 digital inputs expansion module
AVAS_8DO 8 digital outputs expansion module
LICSW_AVAS AVAS License
Optional references are available to enable a quick and complete installation:
(audible and visual devices, light columns,sounder beacon, sirens,…)
Rédigé par MOB, 03/12/22 - Approuvé par JMA, AVASxM DS GB REV 2 / Document non contractuel
SIRIUS
Warning and information
light column
PRESENTATION
FUNCTIONAL CHARACTERISTICS
Sirius light column Sirius junction box
models:
2
With or without sounder/beacon
6 pictograms
Sounder 24Vdc, 105db @ 1m, 3
9 pictograms stages control, up to 32 tones,
Control interface through a 2ml MED approved for « Fire alarm »
multiwire cable (included): +24Vdc,
0v, 1 contact per pictogram, 1 contact
Multicolor LED beacon, 24vdc, green
“test”
/ red / orange color control
Vertical or horizontal mounting with
two clamps (included)
Pictogram backlight: RGB LED. Color
selection (according to IMO
standard) thanks to integrated push
buttons
Pictogram symbol: passive stickers
(according to IMO standard)
Plug & play solution:
setting, animation and priority
management of
pre-programmed pictograms
by using our AVAS system
APPROVALS
Column conforms to the following
regulations:
• IMO Resolution A686 (17)
• IMO Resolution A830 (19)
CONNECTION
MECHANICAL CHARACTERISTICS OVERVIEW
Material Dimensions Weight Mounting
( HxWxD in mm) (Kg)
PMMA
SIRIUS_6V (tube) + 103
Stainless
x 802 xsteel
130 (end cap,
0.9clamp)
surface:
vertical
Dimensions and weight or
SIRIUS_9V 103 x 1102 x 130 1.3
horizontal
Diam. 80mm, Length 700 / 1000mm, < 2kg
SIRIUS_BJ 226 x 180 x 100 0.7 surface
ELECTRICAL CHARACTERISTICS
Main power supply Electrical connection
24Vdc (+30% /-25%)
SIRIUS column:
2ml multiwire cable,
12x0.25mm²
JUNCTION BOX:
18x 2.5mm² terminals
Consumption
block
SIRIUS 6V:
55 mA /picto,
330mA max
SIRIUS_9V:
55 mA /picto
495 mA max
SOUNDER:
34mA @24VDC ENVIRONMENTAL
BEACON:
110 mA CONDITIONS
Temperature limits
0°C to 55°C (functioning)
0°C to 70°C (storage)
REFERENCES Humidity
& OPTIONS
95% Humidity max.
Protection rating
SIRIUS_6V: Light column 6 pictograms (*)
SIRIUS_9V: Light column 9 pictograms (*)
IP IP55
SIRIUS_BJ: Junction box
SIRIUS_BJ_FS: Junction box with sounder & beacon
(*) symbol & orientation of pictograms have to be indicated at the order
Rédigé par MOB, 22/06/22 - Approuvé par JMA,22/06/22 SIRIUS DS GB REV 1 / Document non contractuel
SIRIUS CPL
Warning and information
light column
PRESENTATION
FUNCTIONAL CHARACTERISTICS
Sirius master card Sirius PLC slave junction box Sirius light column
230Vac power supply input
230Vac PLC models:
2
RJ45 Ethernet port input (power supply + data):
over Modbus TCP for 1 input + 2 outputs 6 pictograms
external data exchange & management
DIP-SWITCH addressing 9 pictograms
DIP-SWITCH addressing
Management up to 2 sirius light
Control interface through Sirius
230Vac PLC output (power supply + columns in 24Vdc PLC, one dedicated slave card, a 2 wire cable required
data) output per column
Vertical or horizontal mounting
Management up to 15 Sirius slave cards,
Automatic online light column with two clamps (included)
up to 30 sirius light columns configuration (picto. position & color)
Group or individual signal control with a
Pictogram backlight: RGB LED.
perfect synchronisation
Management up to 4 sounder &
beacon networks, 2 tons in 230Vac:
Pictogram symbol: passive stickers
Online network configuration & (according to IMO standard)
diagnosis 4 visual outputs up to 1,5A
Configuration saved on an embedded max/output
SD card 4 audible outputs up to 0.5A
General Alarm input (dry contact) for max/output
synchronisation with the Public Address
signal
Local test push button
Independent
& sounder
control of beacon APPROVALS
Column conforms to the following
Sounder: 230Vac, 120db regulations:
@1m, 80 tons, 3 stages,
red frame • IMO Resolution A686 (17)
Beacon: Xenon, 15J, 1Hz, orange or • IMO Resolution A830 (19)
red lens • Certified by Bureau Veritas
MED approved
CONNECTION
MECHANICAL CHARACTERISTICS OVERVIEW
Material Dimensions Weight Mounting
( HxWxD in mm) (Kg)
card
PMMA
Master (tube) + Stainless
125 x 235 steel
x 77 (end cap,
0.8clamp)
DIN rail
Dimensions
Slave JB and
264 weight
x 289 x 114 2 surface
SIRIUS_6V
Diam. 103 x 802
80mm, Length 700x/130
1000mm, <0.92kg surface:
vertical
or
SIRIUS_9V 103 x 1102 x 130 1.3
horizontal
ELECTRICAL CHARACTERISTICS
Main power supply Electrical connection
Master card:
230Vac 50/60Hz
- RJ45 socket, Ethernet
com.
- AC power: 3 terminal
blocks in 3 x 2.5mm²
Consumption
Slave JB:
Master Card: 12A max. - AC power supply: 3
terminal blocks in
Slave JB: 8A max. 3x2.5mm²
SIRIUS 6V: 55mA/picto, - AC sounder & beacon:
330mA max 4 terminal blocks in
“2+3”x1.5mm²
SIRIUS_9V: 55mA/
picto, 495mA max - Light column: 2
Sounder: 110mA
terminal blocks in
3x1.5mm²
ENVIRONMENTAL
Beacon: 335mA
SIRIUS column: 3
CONDITIONS
pole 1.5mm² joint
connector Temperature limits
0°C to 55°C (functioning)
0°C to 70°C (storage)
REFERENCES Humidity
& OPTIONS
95% Humidity max.
Protection rating
SIRIUS_CPL_M: Sirius Master card
SIRIUS_CPL_BJ_CTRL: Sirius PLC slave junction box, 2 light column outputs
IP
Master card: IP20
Slave JB & light column: IP55
SIRIUS_CPL_6V: PLC Light column 6 pictograms (*)
Sounder & beacon: IP66
SIRIUS_CPL_9V: PLC Light column 9 pictograms (*)
FSxR230_54PE : sounder & beacon 230VAC, 120db, 15J (**)
(*) symbol & orientation of pictograms have to be indicated at the order
(**) other model possibility on demand (ex: ATEX)
Rédigé par MOB, 23/06/22 - Approuvé par JMA,23/06/22 SIRIUS CPL DS GB REV 1 / Document non contractuel
BNWAS
3
LYNX V3S
BNWAS
PRESENTATION
The LYNX V3S is a countdown timer system which monitors
the awareness of the officer on watch (engine or bridge)
and warns the officers and the crew in case that officer is
unable to carry out their duties.
The LYNX V3S must be periodically reset by the officer on
watch by pressing an illuminated button.
FUNCTIONAL CHARACTERISTICS
Functions Inputs Outputs
Dimensions Weight
(LxlxH)
0,35 KG
Panel :
144 x 72 x 108mm
Front :
144 x 72mm
Housing:
137 x 67mm
ELECTRICAL CHARACTERISTICS
Main power supply Power supply protection
from 9 to 32VDC resettable fuse and
By
diode against polarity
reversal.
Consumption
0,1A nominal
0,5A Max.
REFERENCES ENVIRONMENTAL
& OPTIONS CONDITIONS
Temperature limits
0°C to 55°C (functioning)
0°C to 70°C (storage)
Humidity
95% Humidity max.
Protection rating
IP
IP33
Rédigé par MOB, 26/12/17 - Approuvé par JMA, 22/11/18 LYNX V3S DS GB REV 0 / Document non contractuel
ENERGY
MANAGEMENT
3
ECOMER
Analytical econometer
PRESENTATION
ECOMER EMB is an intelligent system to assist in the economical
operation of the ship. It collects, analyses and displays in real
time the consumption of the various equipment on the ship. This
information allows the captain on the bridge to make decisions
to:
generate consumption savings
FUNCTIONAL CHARACTERISTICS
ECOMER EMB inputs ECOMER EMB outputs
ECOMER TC is a software tool based on a
data collector recorded on board (e. g.
ECOMER EMB).
allows an analysis on shore of the ship’s
It
data by the shipowner, in order to suggest
new modes of operation in order to:
validate investments
suggest new ways of operating
guide investment choices
is also a tool that can be useful to naval
It
architects in a spirit of conceptual analysis.
FUNCTIONAL CHARACTERISTICS
ECOMER TC inputs ECOMER TC outputs
Power consumption per station.
Position and state of the vessel
(position, speed, trim and list, etc.).
Environmental data (temperature,
brightness, wind).
Vessel business data (e.g. tonnage
fished, towing carried out, passengers
carried, etc.).
Time stamping.
REFERENCES
& OPTIONS
analysis service can be proposed to the shipowner.
An
Note: the data collected are the property of the shipowner, and although saved on a MARINELEC server,
in the case of ECOMER TC, they are accessible only by the shipowner unless otherwise agreed in a
contract.
Rédigé par MOB, 30/10/19 - Approuvé par ECOMER FP GB REV 2 / Document non contractuel
EMERGENCY
TELEGRAPH
3
ORION V3
Engine telegraph
PRESENTATION
The ORION V3 is a regulatory safety device ensuring the
transmission of orders between the engine room and the
wheelhouse.
The connection between the different stations (from 2 to 5
stations) is provided by a single cable over Power
Line Communication.
FUNCTIONAL CHARACTERISTICS
Functions Outputs Serial outputs
Number of channels:
Siren output: 1 x RS485 output for 2 functions:
11 max. (10 + « STOP »). 24VDC/100mA
Bridge panel:
Standard version : VDR (Voyage Data Recorder) over
System fault output: 4800 bauds, 8 bits, 1 stop bit;
2 stations – option of 3 to 5. IEC 61162-2
Channel selection: NC dry contact (1A max, 24VDC)
Engine panel:
Switch (ON/OFF) + Led status
Critical order output: ORION printer (ASCII protocol)
Audible signal:
NO dry contact (1A max, 24VDC)
Internal buzzer, 75dB min.
Dimmable light indicators:
( day/night mode).
Luminous indicators test.
Critical order.
System fault:
in case of loss of the control bus.
Control takeover:
from 3 stations or more.
APPROVALS
Bureau Veritas
CONNECTION
MECHANICAL CHARACTERISTICS OVERVIEW
Dimensions Weight Mounting
ELECTRICAL CHARACTERISTICS
Main power supply Consumption
24Vdc (+30% /-25%)
Nominal current
(standby):
25mA per telegraph
Electrical connection
Max. current:
150mA per telegraph
Power line commu-
nication between the
panels: 2x0.75mm2 min.
+ shield
Serial communication:
1 twisted shielded pair
(>=0.50mm²)
ENVIRONMENTAL
CONDITIONS
Temperature limits
0°C to 55°C (functioning)
0°C to 70°C (storage)
Humidity
REFERENCES
95% Humidity max.
Rédigé par MOB, 07/09/22 - Approuvé par JMA, 07/09/22 ORION V3 DS GB REV 1/ Document non contractuel