Programme: Work Based Learning Reporting Period: 12.09.2022 to 11.10.2022 (Month 1) I am allocated to Electromagnetic Compatibility Division as part of my Work Based Learning programme. Here, I have been involving in EMC compliance test & calibration services and EMI modelling & analysis. Following activities were carried out during this period. 1. Understanding basics of EMI&EMC concepts. 2. Learned operating test instruments like vector network analyzer, RF signal generator, spectrum analyzer and digital storage oscilloscope. 3. Calibration of EMI Generators Learned the calibration procedure of Electrical Fast Transient and voltage dips. The calibration of EFT includes the measurement of rise time, pulse width and amplitude. In the calibration of voltage dips, the parameters like peak to peak voltage, dip voltage and dip time period are measured. Digital storage oscilloscope was used to measure aforementioned parameters. 4. Calibration of Monopole Antenna Learned the calibration procedure of monopole antenna. Vector network analyzer was used to measure antenna factor. 5. Understanding EMI Modelling & Analysis Software Learned Ansys SIWave software, which is used for EMI, signal and power integrity analysis of PCB design. Resonance and SYZ parameter analysis has been carried out for a basic PCB design. WORK REPORT Intern Name: Roshini P Programme: Work Based Learning Reporting Period: 12.10.2022 to 11.11.2022 (Month 2) 1. Conducted Emission Measurements Learned the basics of conducted emission. Conducted emission measurement test procedure was learned. A medical product has been tested for conducted emission using LISN. The test has been carried out as per IEC 60601-1-2 standards. 2. Calibration of LISN Learned the calibration procedure of LISN. Line Impedance Stabilization Network is used to stabilize the impedance of the line when connected to EUT. In the calibration process, insertion loss, impedance,phase angle and isolation parameters are measured. Vector network analyzer was used to measure the aforementioned parameters. 3. Calibration of ISN Learned the calibration procedure of ISN. Impedance Stabilization Network is used in telecommunication line to stabilize the impedance. Calibration of ISN was done by measuring impedance, longitudinal conversion loss, voltage division factor and decoupling using vector network analyzer. 4. Calibration of Antenna Learned the calibration procedure of antennae. Antenna calibration was done to measure return loss and antenna factor. Antenna calibration was done using RF signal generator and spectrum analyzer in semi anechoic chamber. Antenna factor was measured by keeping antenna at 1m, 3m and 10m distance. Antenna factor are measured using similar antenna as reference. 5. Calibration of EMI Generators Learned the calibration procedure of damped oscillatory and automotive test system. In Calibration of damped oscillatory, the parameters like amplitude, rise time and oscillating frequency are measured. In automotive test system, the parameters like rise time, amplitude and pulse width are measured. Digital storage oscilloscope was used to measure aforementioned parameters.