1 --- Overview
2 --- Up date
3 --- Power Consumption
1. Overview
When you prepare a backup unit (E.g. UPS) for a TD1232/TD816 system, please refer to
this guide (Ref No. 20000131-1) . It shows you the power consumption for TD1232/TD816
main unit and each optional card.
2. Up date
Edition Date of issue Modification Code
st st
1 7 Feb., 2000 1 Edition
2nd 12 May, 2000 Add TD1232/TD816 E, CE, SP, NL, JT and optional card etc. (B)
Calculation sample
Configuration
TD1232 55W
TD170 10W
TD146 6W
TD142 x 4 16W (3.5W x 4)
SLT x 8 4W (0.5W x 8)
D-PITS x 20 50W (2.5W x 20)
Total 141 W
*1 This is the maximum current when three TD194s are connected by DC input/output
interfaces (only the main TD194 is connected to an AC outlet).