ADVANCED ELECTROSURGERY WITH SMOKE EVACUATOR

ERBE VIO 300D & IES3


Made in Germany

Features :
Electorsurgery unit : VIO 300D
Automatic output dosage for all regulative technologies
Precise power output adjusted to the individual indication
New and improved CUT and COAG functions
Display-supported neutral electrode safety system NESSY provides interactive assistance when positioning the return elect
Individually configurable programs in simple text: switch on the unit and begin working
ReMode function: "remote control" via the handle or foot switch straight from the sterile field
Designed to provide solutions for specific medical indications in the medical fields gastroenterology, ENT, and bronchoscop

Automatic Power Dosages


− efficient operation with optimal results and a high degree of safety; the ERBE Power Peak System takes specific features
account and provides automatic support; improved cutting effects and reduced thermal damage to tissue; less stress for

ERBE arcing regulation controls the intensity of the arcs required for the cut between the active electrode and the target ti
Erbe voltage regulation constantly maintains a pre-set voltage during the entire coagulation process. This ensures that the
required is delivered
wer output level over a longer period, thereby creating an effective, previously unknown soft coagulation.

BiClamp Upgrade
− Support the ERBE BICLAMP. The bipolar clamp for the coagulation/resp. Thermofusion of vessels with a large lumen and
structures up to diameter 7mm and withstand 7x systolic normal, without dissection and easy to use.

Innovative development : the Neutral Electrode Safety System NESSY


− With the NESSY safety concept and the ERBE patient plate NESSY Ω the VIO 300D sets new standards for patient safety.
−“leading
NESSY monitors the applications of the patient plate, providing the user with information which is graphically displayed o
edge” effect,
i.e. the development
− Because of its new shape the NESSY Ω Neutral Electrode can be applied irrespective of direction. It practically precludes
of high current
densities at the
electrode edges,
improve patient safety.
TECHNICAL DATA
VIO 300D
Power output
Maximum CUT output : 300 watt at 500 ohm
Maximum COAG output : up to 200 watt
Safety system : NESSY
Frequency : 350 kHz
Main connection
Power frequency : 50 / 60 Hz
Power input during stand-by : 40 Watts
System voltage : 100-120 / 220-240 Volt
Potential equalization connection : yes
Dimensions and weight
Width x Height x Depth : 410 x 165 x 380 mm
Weight : 9,5 kg
IES3 Smoke Evacuator

Power connection
Rated supply voltage 100–240 V AC (± 10 %)
Rated supply frequency 50/60 Hz
Line current max. 3 A
Power consumption max. 300 watts
Stand-by 12 watts at 230 V, 12 watts at 115 V
Potential equalization connection Yes
Power fuse T 4 A H / 250 V

Filter specification
ULPA-15 in accordance with EN 1822-3:2011 and EN 1822-5:2011, corresponds to the requirements of ISO 16571 smoke evacuation d

Extraction performance
≤ 730 l/min (maximum turbine power, th) ≤ 300 l/min (with main filter cartridge, automatic shut-off)

Dimensions and weight


Width x height x depth 205 x 280 x 404 mm
Weight 9.7 kg including main filter cartridge
Display size 5.7 inches

Ambient conditions for operating the unit


Temperature +10 °C to +40 °C
Relative humidity 15 %–85 %, non-condensing
Air pressure 54 kPa–106 kPa
Max. operating height 5000 m over SL

Standards
Classification in accordance with MDD 93/42 EEC I
Protection class in accordance with EN 60 601-1 I
Type in accordance with EN 60 601-1 CF
sitioning the return electrode

y, ENT, and bronchoscopy, and for use in operative outpatient procedures

m takes specific features of the initial cutting stage into


to tissue; less stress for the patient.

ectrode and the target tissue and contantly adjusts them


ss. This ensures that the precise amount of power

with a large lumen and vascular tissue structures

ards for patient safety.


is graphically displayed on the monitor.
. It practically precludes the troublesome “leading edge” effect, i.e.
16571 smoke evacuation devices