You are on page 1of 3

SERVICE REPORT

Ship Owner Service Job No. / dated


Ship's Managerment PO No.
Ship's Agent Vessel LEOPARD
Port SINGAPORE IMO No. 9284594
Service engineer in action LE MANH HA, DANG CONG THU Service Type REPAIR
CARGO TANKET MONITOR SYSTEM TYPE:
Date of installation Equipment Serial No.

A: Fault reported B: Action taken C: Results D: Supply


A) - ENGINEERS ATTEND ON BOART AT 13:00 12 DEC 2022 FROM ANCHORAGE SINGAPORE TO REPAIR
CARGO SAAB TANK SYSTEM WITH PROBLEMS SHOW BELOW:
- Host communication error
- Tank 4P, Slop S is warning "clean antenna"
- Tank 5S,6S,Slop is warning " inval.measurem"
- Tank Slop P display: "pressure sensor fail"
B) - Clean RS485 communicatino card in I/O box
- Disconnect the deck cable for the failing TGU from the SCS, remove the TGU cover for checking and clean all the
terminals of the tank 5S, 6S, Slop P, Slop S
- Clean the inside of the cone, clean wipe the teflon cone inside the antenna using a soft rag as procedure by maker
- Repair cables and connection of pressure sensor
- Restart TGU, and restart system as recommended give by the maker but the communication error is not fix
C) - After action taken as above, only pressure sensor fail is fixed, other errors can't be fixed
Note:
- Recomment contact maker to service for other errors
- Need renew seal oring for tank 6s

D) -
Spare parts
Qty. Part Description / Part No. unit Warranty
1

Place of Service * Signature Service Engineer: Signature Ship's C/E


Singapore
Date of Service: dd/mm/yyyy
12/12/2022
End Time of Service: hh/mm*
DANG CONG THU