Ship's Managerment PO No. Ship's Agent Vessel LEOPARD Port SINGAPORE IMO No. 9284594 Service engineer in action LE MANH HA, DANG CONG THU Service Type REPAIR CARGO TANKET MONITOR SYSTEM TYPE: Date of installation Equipment Serial No.
A: Fault reported B: Action taken C: Results D: Supply
A) - ENGINEERS ATTEND ON BOART AT 13:00 12 DEC 2022 FROM ANCHORAGE SINGAPORE TO REPAIR CARGO SAAB TANK SYSTEM WITH PROBLEMS SHOW BELOW: - Host communication error - Tank 4P, Slop S is warning "clean antenna" - Tank 5S,6S,Slop is warning " inval.measurem" - Tank Slop P display: "pressure sensor fail" B) - Clean RS485 communicatino card in I/O box - Disconnect the deck cable for the failing TGU from the SCS, remove the TGU cover for checking and clean all the terminals of the tank 5S, 6S, Slop P, Slop S - Clean the inside of the cone, clean wipe the teflon cone inside the antenna using a soft rag as procedure by maker - Repair cables and connection of pressure sensor - Restart TGU, and restart system as recommended give by the maker but the communication error is not fix C) - After action taken as above, only pressure sensor fail is fixed, other errors can't be fixed Note: - Recomment contact maker to service for other errors - Need renew seal oring for tank 6s
D) - Spare parts Qty. Part Description / Part No. unit Warranty 1
Place of Service * Signature Service Engineer: Signature Ship's C/E
Singapore Date of Service: dd/mm/yyyy 12/12/2022 End Time of Service: hh/mm* DANG CONG THU