ASSIGNMENT: ESTIMATION OF EARTHWORKS

EARTHWORKS EARTHWORKS EARTHWORKS EARTHWORKS


EXCAVATION EXCAVATION EXCAVATION EXCAVATION
Footing Dimensions Footing Dimensions Wall Footing Dimensions Wall Footing Dimensions
Length 1.20 m Length 1.20 m Length 32.00 m Length 32.00 m
Width 1.20 m Width 1.20 m Width 0.60 m Width 0.60 m
Height 0.40 m Height 0.40 m Height 0.80 m Height 0.80 m
Space for formworks 0.30 m Space for formworks 0.00 m Space for formworks 0.20 m Space for formworks 0.00 m
Excavation Dimensions Excavation Dimensions Excavation Dimensions Excavation Dimensions
FOOTING FOOTING WALL FOOTING WALL FOOTING
Length 1.80 m Length 1.20 m Length 32.00 m Length 32.00 m
Width 1.80 m Width 1.20 m Width 1.00 m Width 0.60 m
Height 1.75 m Height 1.75 m Height 0.95 m Height 0.95 m
Volume of Excavation of 1 footing 5.67 m3 Volume of Excavation of 1 footing 2.52 m3 Volume of Excavation of 1 footing 30.40 m3 Volume of Excavation of 1 footing 18.24 m3
Quantity of Footing 14.00 pcs Quantity of Footing 14.00 pcs Quantity of Wall Footing 1.00 pc Quantity of Footing 1.00 pc
Total Bank Volume of Excavation 79.38 m3 Total Bank Volume of Excavation 35.28 m3 Total Bank Volume of Excavation 30.40 m3 Total Bank Volume of Excavation 18.24 m3

BACKFILL BACKFILL BACKFILL BACKFILL


Dimensions of void to be backfilled Dimensions of void to be backfilled Dimensions of void to be backfilled Dimensions of void to be backfilled
Note: If column volume is neglected Note: If column volume is neglected Note: If volume of wall footing is considered Note: If volume of wall footing is considered
Length 1.80 m Length 1.20 m WF 0.48 m2 WF 0.48 m2
Width 1.80 m Width 1.20 m Length 32.00 m Length 32.00 m
Height 1.20 m Height 1.20 m WALL FOOTING Width 1.00 m WALL FOOTING Width 0.60 m
Compacted volume of fill for 1 footing 3.888 m3 Compacted volume of fill for 1 footing 1.73 m3 Height 0.95 m Height 0.95 m
Quantity of Footing 14.00 pcs Quantity of Footing 14.00 pcs Compacted volume of fill for 1 footing 15.040 m3 Compacted volume of fill for 1 footing 2.880 m3
Total Compacted volume required 54.432 m3 Total Compacted volume required 24.19 m3 Quantity of Footing 1.00 pc Quantity of Footing 1.00 pc
Note: If column volume is considered Note: If column volume is considered Total Compacted volume required 15.040 m3 Total Compacted volume required 2.880 m3
C1 0.10 m2 C1 0.10 m2
Length 1.80 m Length 1.20 m
Width 1.80 m Width 1.20 m
FOOTING FOOTING
Height 1.20 m Height 1.20 m
Compacted volume of fill for 1 footing 3.768 m3 Compacted volume of fill for 1 footing 1.608 m3
Quantity of Footing 2.00 pcs Quantity of Footing 2.00 pcs
Total Compacted volume required 7.536 m3 Total Compacted volume required 3.216 m3
C2 0.09 m2 C2 0.09 m2
Length 1.80 m Length 1.20 m
Width 1.80 m Width 1.20 m
Height 1.20 m Height 1.20 m
Compacted volume of fill for 1 footing 3.780 m3 Compacted volume of fill for 1 footing 1.620 m3
Quantity of Footing 12.00 pcs Quantity of Footing 12.00 pcs
Total Compacted volume required 45.360 m3 Total Compacted volume required 19.440 m3
Total Compacted volume required 52.896 m3 Total Compacted volume required 22.656 m3