Acknowledgements
This IOGP Specification was prepared by a Joint Industry Programme 33
Standardization of Equipment Specifications for Procurement organized
by IOGP with support by the World Economic Forum (WEF).

Disclaimer
Whilst every effort has been made to ensure the accuracy of the information
contained in this publication, neither IOGP nor any of its Members past present or
future warrants its accuracy or will, regardless of its or their negligence, assume
liability for any foreseeable or unforeseeable use made thereof, which liability is
hereby excluded. Consequently, such use is at the recipient’s own risk on the basis
that any use by the recipient constitutes agreement to the terms of this disclaimer.
The recipient is obliged to inform any subsequent recipient of such terms.
This publication is made available for information purposes and solely for the private
use of the user. IOGP will not directly or indirectly endorse, approve or accredit the
content of any course, event or otherwise where this publication will be reproduced.

Copyright notice
The contents of these pages are © International Association of Oil & Gas Producers.
Permission is given to reproduce this report in whole or in part provided (i)
that the copyright of IOGP and (ii) the sources are acknowledged. All other rights are
reserved. Any other use requires the prior written permission of IOGP.
These Terms and Conditions shall be governed by and construed in accordance
with the laws of England and Wales. Disputes arising here from shall be exclusively
subject to the jurisdiction of the courts of England and Wales.

IOGP S-707D Version 1.0 Page 2 of 13


Data Sheet for
Actuators for On-off Valves

Foreword

This specification was prepared under Joint Industry Programme 33 (JIP33) "Standardization of Equipment Specifications for
Procurement" organized by the International Oil & Gas Producers Association (IOGP) with the support from the World Economic
Forum (WEF). Companies from the IOGP membership participated in developing this specification to leverage and improve
industry level standardization globally in the oil and gas sector. The work has developed a minimized set of supplementary
requirements for procurement, with life cycle cost in mind, resulting in a common and jointly agreed specification, building on
recognized industry and international standards.

Recent trends in oil and gas projects have demonstrated substantial budget and schedule overruns. The Oil and Gas
Community within the World Economic Forum (WEF) has implemented a Capital Project Complexity (CPC) initiative which
seeks to drive a structural reduction in upstream project costs with a focus on industry-wide, non-competitive collaboration and
standardization. The CPC vision is to standardize specifications for global procurement for equipment and packages. JIP33
provides the oil and gas sector with the opportunity to move from internally to externally focused standardization initiatives and
provide step change benefits in the sector's capital projects performance.

This specification has been developed in consultation with a broad user and supplier base to realize benefits from
standardization and achieve significant project and schedule cost reductions.

The JIP33 work groups performed their activities in accordance with IOGP's Competition Law Guidelines (November 2014).

IOGP S-707D Version 1.0 Page 3 of 13


Data Sheet for
Actuators for On-off Valves

Introduction

The purpose of this equipment data sheet is to define buyer specific requirements for the procurement of actuators for on-off
valves in accordance with IOGP S-707 for application in the petroleum and natural gas industries. The data sheet provides
project specific requirements where the supplementary specification and its parent standard require the purchaser to define an
application specific requirement. It also includes information required by the purchaser for technical evaluation purposes.
Additional purchaser supplied documents are also listed in the data sheets, to define scope and technical requirements for
enquiry and purchase of the equipment.

This data sheet shall be used in conjunction with the supplementary requirements specification IOGP S-707, information
requirements specification IOGP S-707L and quality requirements specification IOGP S-707Q which together comprise the full
set of specification documents. The Introduction section in the supplementary requirements specification provides further
information on the purpose of each of these documents and the order of precedence for their use.

JIP33 Specification for Procurement Documents


Data Sheet

IOGP S-707D Version 1.0 Page 4 of 13


S-707D Data Sheet for

Issue
Row

 Actuators for On-off Valves


2 Tag No. : Insert Tag Number
3 Service : Insert Service Description
4 Ref. Clause Description Additional notes
5 General
6 Clause 17 Conformity Assessment System (CAS) level : D
7 Outside environmental conditions
8 10.1, 7.0 Location : Select
9 10.1, 7.0 Climate classification : Select
10 10.1, 7.0 Environmental classification : Input Data
11 8.1.5 a) to h), 8.1.6 a), c) to e) Minimum ambient temperature : Input Data °C
12 8.1.5 a) to h), 8.1.6 a), c) to e) Maximum ambient temperature : Input Data °C
13 10.1 Maximum relative humidity : Input Data %
14 Electric supply
15 6.2.1 Motor power supply : Input Data Select
16 6.2.1 Power supply frequency : Input Data Hz
17 6.2.1 Number of phases : three
18 7.1.1.1.5 Control voltage : Input Data Select
19 Pneumatic supply
20 8.1.6 b), 8.2 Network minimum air supply pressure : Input Data bar g
21 8.1.6 b), 8.2 Network maximum air supply pressure : Input Data bar g
22 9.3.1.1 Network air supply design pressure : Input Data bar g
23 6.2.2 Control fluid type : compressed air
24 Hydraulic supply
25 8.1.6 b), 8.2 Network minimum hydraulic supply pressure : Input Data bar g
26 8.1.6 b), 8.2 Network maximum hydraulic supply pressure : Input Data bar g
27 9.3.1.1 Network hydraulic supply design pressure : Input Data bar g
28 6.2.3, 6.2.4.2 Hydraulic oil : Input Data
29 6.2.3 Hydraulic oil flash point (temperaure@pressure) : Input Data
30 For actuator material selection (additional process data for pipe line gas actuators only)
31 8.1.2 minimum operating (pipe line) pressure : Input Data bar g
32 8.1.2 maximum operating (pipe line) pressure  : Input Data bar g
33 10.2, 10.7 H2S presence (ISO 15156/17945 service) : Select
34 10.2, 10.7 H2S concentration : Input Data %
35 10.2, 10.7 SO2 presence : Select
36 10.2, 10.7 SO2 concentration : Input Data %
37 10.5 Hydrogen embrittlement service : Select
38 10.5 Hydrogen concentration : Input Data %

Page 5 of 13
IOGP S-707D Version 1.0
S-707D Data Sheet for

Issue
Row

 Actuators for On-off Valves


2 Tag No. : Insert Tag Number
3 Service : Insert Service Description
4 Ref. Clause Description Additional notes
5 Valve process data, valve torque data and actuator general design data
6 Process data for valve torque determination
7 8.1.2 Long stand still time (staying in same position) : Input Data months
8.1.2, 8.1.5 a) to h), 8.1.6 a), c)
8
to e) Minimum operating temperature : Input Data °C
(8.1.2 para 6 new), (8.1.5 a to h),
9
(8.1.6, a, c to e) Maximum operating temperature : Input Data °C
Shutoff differential pressure (process shutoff
10 8.1.2 differential or maximum line static pressure or flange Input Data bar
rated pressure) :
Service (clean, non-clean, lubricating, non-lubricating,
11 8.1.2 Input Data
sticky, slurry) :
12 Valve data
13 6.4, Table 8 Action on loss of supply energy : Select
14 6.4, Table 8 Action on loss of control signal : Select
8.1.2, 8.2, 9.1, 9.2, 8.1.7.2.1,
15
8.1.7.3.1 MAST : Input Data N-m
16 8.1.2, 8.2 Break to open torque/thrust : Input Data Select
17 8.1.2, 8.2 Run to open torque/thrust : Input Data Select
18 8.1.2, 8.2 End to open torque/thrust : Input Data Select
19 8.1.2, 8.2 Break to close torque/thrust : Input Data Select
20 8.1.2, 8.2 Run to close torque/thrust : Input Data Select
21 8.1.2, 8.2 End to close torque/thrust : Input Data Select
22 8.1.2, 8.2 Break away angle or % of stroke (open direction) : Input Data Select
23 8.1.2, 8.2 Break away angle or % of stroke (close direction) : Input Data Select
Minimum operating time with all actuator control
24 8.1.3, Table 8 Input Data s
components (open direction) :
Minimum operating time with all actuator control
25 8.1.3, Table 8 Input Data s
components (close direction) :
Maximum operating time with all actuator control
26 8.1.3, Table 8 Input Data s
components(open direction) :
Maximum operating time with all actuator control
27 8.1.3, Table 8 Input Data s
components (close direction) :
28 General
6.3.1, 7.17.1.1, 7.17.1.2,
29 7.17.2.1, 7.17.2.2, 7.17.2.3, Application : Select
7.17.2.4
30 P & ID reference : Input Data
31 7.8 Actuator with accessories and mounting kit weight : Input Data kg
32 7.0 Hazardous area classification : Input Data
33 7.0 Hazardous area certification standard : Select
Hazardous protection method or certification
34 7.0 Input Data
marking :
35 7.17.1.2, Table D.1 SIL capability for the assembly : Select
SIL calculation for the assembly and actuator control
36 7.17.1.2 Select
components :
37 Actuator model number : Input Data
38 Actuator manufacturer : Input Data
39 Actuator serial number : Input Data
Pressure containing parts and pressure vessel design
40 7.2 Select
code :
41 7.18 Actuator fire proofing : Select
42 7.18 Fire classification : Select
43 7.18 Fire proofing exposure time for pool or jet fire : Input Data min
Fire proofing exposure temperature for pool or jet
44 7.18 Input Data °C
fire :
45 7.18 Fire proofing method : Select
46 Actuator design
47 6.2.1, 6.2.2, 6.2.3, 6.2.4.1 Actuator type : Select
48 6.1 Movement required : Select
49 7.0 Actuator mounting standard : Select
50 7.0 Ingress protection : IP66
51 8.1.2, 8.1.3 Actuator sizing safety factor : Input Data
52 Clause 14 Surface protection corrosivity category : Select
53 Clause 14 Actuator coating system : Select
54 Clause 14 Onshore surface protection durability category : high
55 Clause 14 Offshore surface protection durability category : high
56 Actuator colour : Input Data
57 Manual override
58 6.2.1, 7.9.1, 7.9.2.1 Manual override : Select
59 7.1.4.3, 7.9.1 Type : Select
60 7.9.2.5 Removable or lockable : Select

IOGP S-707D Version 1.0 Page 6 of 13


S-707D Data Sheet for

Issue
Row

 Actuators for On-off Valves


2 Tag No. : Insert Tag Number
3 Service : Insert Service Description
4 Ref. Clause Description Additional notes
5 Electric actuators
6 10.1, Table 7 Enclosure material : Input Data
7 Table 8 Actuator stop by : limit
8 7.1.1.1.2, 7.1.1.1.4 Number of consecutive valve strokes : Input Data
9 7.1.1.1.2, 7.1.1.1.4 Number of starts per hour : Input Data
10 Table 8 Control selection : Select
11 Table 8 Selector switch : Select
12 Table 8 Selector switch lockable : Select
13 7.1.1.2.1 Local indication - open : green
14 7.1.1.2.1 Local indication - closed : red
15 Motor
16 7.1.1.1.2 Duty : Select
17 6.2.1, Table 3 Nominal motor power : Input Data
18 Cable entries
19 7.1.1.1.9 Number of cable entries : three
20 7.1.1.1.9 Power cable entry size : Input Data
21 7.1.1.1.9 Control cable entry sizes : Input Data
22 Hard wired, network input / output
Hard wired command signals (DO from control
23 7.1.1.2.3 Input Data
system) :
24 Hard wired analog signals (AI to control system) : Input Data
7.1.1.1.6, 7.1.1.2.4, 7.1.1.2.5, Hard wired alarm, status signals (DI to control
25 Input Data
7.1.1.2.6 system) :
26 7.1.1.1.6 Relay contact for DI : SPDT
Network control card or communication card
27 Table 8 Input Data
protocol :
28 Torque/Thrust
29 8.1.7.2.1 Stall torque : Input Data N·m
30 8.1.2, 8.1.7.1 Spring to start torque/thrust : Input Data Select
31 8.1.2, 8.1.7.1 Spring to run torque/thrust : Input Data Select
32 8.1.2, 8.1.7.1 Spring to end torque/thrust : Input Data Select
33 8.2, 8.1.7.2.2 Actuator maximum torque/thrust : Input Data Select

IOGP S-707D Version 1.0 Page 7 of 13


S-707D Data Sheet for

Issue
Row

 Actuators for On-off Valves


2 Tag No. : Insert Tag Number
3 Service : Insert Service Description
4 Ref. Clause Description Additional notes
5 Pneumatic/Hydraulic/Electro-hydraulic actuators
6 6.3.1, 6.3.2 Actuator configuration : single acting - spring return
7 6.2.1, 6.2.2, 6.2.3, 6.3.3 Actuator type : Select
8 6.2.1, 6.2.2, 6.2.3 Actuator style : traditional
9 7.12 Adjustable travel stop : Select
10 6.3.1 Double acting fail safe actuators sized for (strokes) : Input Data
11 6.3.1 Actuator swept volume : Input Data m³
12 7.0 Actuator design pressure : Input Data bar g
Hydraulic system operating pressure (for self
13 7.1.4.1 Input Data bar g
contained electro-hydraulic actuators) :
14 Torque/Thrust
15 8.1.2, 8.2, 8.1.7.1, 8.1.7.3.3 Spring to start torque/thrust : Input Data Select
16 8.1.2, 8.2, 8.1.7.1, 8.1.7.3.3 Spring to run torque/thrust : Input Data Select
17 8.1.2, 8.2, 8.1.7.1, 8.1.7.3.3 Spring to end torque/thrust : Input Data Select
Air/hydraulic to start torque/thrust (at minimum
18 8.1.7.1, 8.1.7.3.1, 8.1.7.3.2 Input Data Select
network supply pressure) :
Air/hydraulic to run torque/thrust (at minimum
19 8.1.7.1, 8.1.7.3.1, 8.1.7.3.2 Input Data Select
network supply pressure) :
Air/hydraulic to end torque/thrust (at minimum
20 8.1.7.1, 8.1.7.3.1, 8.1.7.3.2 Input Data Select
network supply pressure) :

IOGP S-707D Version 1.0 Page 8 of 13


S-707D Data Sheet for

Issue
 Actuators for On-off Valves
Row

2 Tag No. : Insert Tag Number


3 Service : Insert Service Description
4 Ref. Clause Description Additional notes
5 Accessories selection
6 9.3.2.1 Filter : Select
7 9.3.2.3 Filter regulator : no
8 9.3.2.1, 9.3.2.5, 9.3.3.1 Control panel : Select
9 6.3.1, 7.18, 9.3.1.1, 9.3.4 Air receiver : Select
6.3.1, 6.2.4.1, 7.18, 9.3.1.1,
10
9.3.5.1, 9.3.5.2, 9.3.5.3, 9.3.5.4 Accumulator : Select
11 8.1.3 Speed control : not required
12 9.3.7.1 Air lock relay / directional valves : Select
13 9.3.8.1, 9.3.8.3, 9.3.8.4, 9.3.8.5 Solenoid valve : Select
14 7.1.1.3, 9.3.9.1, 9.3.9.3 Limit switch : Select
15 7.17.2.3 Position transmitter : Select
7.17.2.4, 9.3.10.1, 9.3.10.2.1,
16 9.3.10.2.2, 9.3.10.2.3, 9.3.10.2.4, Controller (Positioner) : Select
9.3.10.2.5

7.17.2.1, 7.17.2.2, 7.17.2.3,


17
7.17.2.4, 9.3.10.1 Partial stroke device : Select
18 Table D.1 Local reset : not required
19 Common requirements
20 7.0 Cable entry on accessories : Input Data
21 7.0 Ingress protection for accessories : Select
22 7.0 Hazard protection method for instruments : Input Data
23 Filter or Filter regulators
24 9.3.2.6 Type : Input Data
25 6.2.2, 7.0, 9.3.2.1 Filter mesh size : Input Data micron
26 10.1 Wetted part material : Select
27 Manufacturer : Input Data
28 Model number : Input Data
29 Control panel
30 Mounting : on actuator
31 9.3.3.1 Type : back plate
32 Supply pressure gauge at inlet of the control panel : not required
33 9.3.3.1 Sun shade : top and back side
34 Air receiver
35 Clause 15 Tag number : Input Data
36 10.1, Table 6 Air receiver material : Select
37 7.18 Fire proofing for air receiver : Select
38 6.3.1 Air receiver volume (at minimum temperature) : Input Data m³
39 Accumulator
40 Clause 15 Tag number : Input Data
41 10.1, Table 6 Accumulator material : Select
42 7.18 Fire proofing for accumulator : Select
43 6.3.1 Accumulator volume (at minimum temperature) : Input Data m³
44 Miscellaneous instruments for accumulators
45 Pressure gauge : Input Data
46 9.3.1.1 Relief valve : Input Data
47 Solenoid valves
48 Clause 15 Tag number #1 : Input Data
49 Tag number #2 : Input Data
50 Tag number #3 : Input Data
51 Mounting : Select
52 9.3.8.1 Configuration : auto reset
53 9.3.8.2 Coil insulation : Class F
54 10.1 Body material : Select
55 10.1 Housing material : Select
56 Coil voltage : Input Data Select
57 9.3.8.1 Power consumption : Input Data W
58 Manufacturer : Input Data
59 Model number : Input Data
60 Limit switches
61 Clause 15 Tag number #1 : Input Data
62 Tag number #2 : Input Data
63 Tag number #3 : Input Data
64 Mounting : Select
65 9.3.9.1 Type : Input Data
66 Contact rating : Input Data
67 Manufacturer : Input Data
68 Model number : Input Data

IOGP S-707D Version 1.0 Page 9 of 13


S-707D Data Sheet for

Issue
 Actuators for On-off Valves
Row

2 Tag No. : Insert Tag Number


3 Service : Insert Service Description
4 Ref. Clause Description Additional notes
69 Controller (Positioner)
70 Clause 15 Tag number : Input Data
71 Mounting : Select
72 Output signal : Input Data mA
73 Supply voltage : Input Data V DC
74 Communication protocol : Input Data
75 Manufacturer : Input Data
76 Model number : Input Data
77 Partial stroke testing
78 A.2, Table 8 Partial stroke testing : Select
79 PST initiation : Select
80 Position transmitter
81 Clause 15 Tag number : Input Data
82 Mounting : Select
83 Output signal : Input Data mA
84 Supply voltage : Input Data V DC
85 Manufacturer : Input Data
86 Model number : Input Data

IOGP S-707D Version 1.0 Page 10 of 13


S-707D Data Sheet for

Issue
Row
Actuators for On-off Valves
2 Tag No. : Insert Tag Number
3 Service : Insert Service Description
4 PURCHASE ORDER SPECIFIC REQUIREMENTS
5 Delete this sheet if not required
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95

IOGP S-707D Version 1.0 Page 11 of 13


Data Sheet for
 Actuators for On-off Valves

Guidance on the use of this data sheet

To be used in conjunction with :


IOGP S-707 Supplementary Specification to ISO 12490 Actuators for On-off Valves.

This data sheet is set-up to be used in electronic format by both the purchaser/user and the supplier/manufacturer.

This data sheet provides reference back to the parent standard or the supplementary specification where relevant.

Default values (if applicable) have been set according to essential minimum requirements as an integral part of this
specification and should only be changed where specific justification can be provided.

The Supplement sheet is provided in an open format sheet for application of specific items not covered in the main part
of the data sheet. This sheet is not intended to modify requirements defined in the supplementary requirements
specification.

The data sheet includes a revision (issue) column on the right hand side for use by the purchaser/user. After the first
issue, for each subsequent revision of the data sheet that is issued to suppliers for enquiry or purchase, the
purchaser/user should use the issue column to denote that the data on a specific row has been updated since the
previous revision. This will enable the supplier to easily identify where changes have been made.

Legend Select Supplier/manufacturer completed, pick list of pre-defined values (may be pre-populated
with a default value).
Input data Supplier/manufacturer completed data entry.

Select Purchaser/user completed, pick list of pre-defined values (may be pre-populated with a
default value).
Input data Purchaser/user completed data entry.

Select Either supplier/manufacturer or purchaser/user completed, pick list of pre-defined values


(may be pre-populated with a default value).
Input Data Either supplier/manufacturer or purchaser/user completed data entry.

Select Selection of units from a pre-defined pick list.

IOGP S-707D Version 1.0 Page 12 of 13

You might also like