Professional Documents
Culture Documents
Installation manual
Welcome to DDS!
Our complete team is very excited to present DDS-CAD 10 and wel-
come you as a user of one of the most advanced BIM solutions cur-
rently on the market. For over 30 years, DDS has been a market leader
in Open BIM and model based design software for MEP engineers.
With many intelligent and automated features, a highly flexible and
intuitive user interface, DDS-CAD 10 assures an uncompromising de-
sign efficiency.
Do not wait any longer, install the software now and experience the
full potential of DDS-CAD yourself.
As a partner, DDS is here to assist you. This begins with the instal-
lation and extends beyond daily design questions, project support,
individual training and further product development. A highly quali-
fied team of technicians and engineers with practical experience are
directly at your disposal whenever you have any questions.
4. Network installation
4.1 Preparations 21
4.2 Setup configuration 23
4.3 Run setup on workstations 29
5. Update Dongle
5.1 Local dongle 31
5.2 Network dongle 32
6. System Requirements 33
1. Installation and Tools
1.0 Preliminary remarks
For DDS-CAD the installation types “local” and “network” are avail-
able. The desired installation type can be selected in the installation
menu. The setup DVD also contains several tools (additional applica-
tions).
1. Local installation
2. Network installation
3. Tools
Use this method if you would like to install DDS-CAD locally on a sin-
gle workstation or want to install the software on multiple worksta-
tions in a network.
It is irrelevant whether:
The network installation can be used to save time. Use this option if
you intend to install DDS-CAD on multiple workstations in a network
at the same time.
The installation DVD contains several additional tools that can be in-
stalled:
To create PDF files in DDS-CAD you can install the PDF printer
“PDFCreator”.
The tool “Install License Update” is used by DDS support during re-
mote admin when update issues have occurred.
Please note:
When installing DDS-CAD for the first time the dongle should
not be inserted before starting the installation procedure. After
completing the installation a restart of the computer is required,
afterwards you can insert the dongle.
After you have inserted the DVD, the installation process will start au-
tomatically. If the installation does not start, open Windows Explorer
and run the “Install.exe” from the DVD.
Select a market and language for DDS-CAD and confirm with “OK”:
Enter your user name and company name and indicate for which us-
ers DDS-CAD should be installed:
If your projects or user data should be stored on the network, the net-
work folder must be connected to a network drive on your computer.
DDS-CAD does not support UNC paths (server share e.g. \\Server-
name\folder\) in all functions. Therefore, we recommend not using
them.
Enter the correct locations or use the default folders and press “Next”.
Please note:
If you use Microsoft Windows Vista or newer, you may not use or
create the folders for user files and projects in the DDS program
path (C:\Programfiles\DDS\...). Microsoft Vista and newer versi-
ons of Windows do not provide direct write access to the Program
folders.
When you select the setup type “Custom” you can select whether the
modules “Crystal Reports” and “Polysun Inside” have to be installed.
When deselecting the module “Crystal Report” DDS-CAD cannot cre-
ate reports (e.g. output of calculation results and part lists). The mod-
ule “Polysun Inside” is used for calculating the yield of PV systems:
The setup is now ready to install DDS-CAD. Select “Install” to start the
installation procedure. To change or check the settings you have se-
lected, use “Back”.
After the restart you can insert the USB dongle in the computer. The
USB dongle will be automatically recognized; afterwards you can
launch DDS-CAD and update your dongle if required (see chapter 5).
Please note:
You cannot refer to the folder locations that are used by DDS-CAD 9.
In case you would like use separated user data exclusively for DDS-
CAD 10, you can specify a new location for your user folder. The project
folder location can be similar to the one used for DDS-CAD 9.
Please note:
Project that are opened in DDS-CAD 10, cannot be opened any-
more in an older version of DDS-CAD.
After you have inserted the DVD, the installation will start automati-
cally. If the installation procedure does not start automatically, open
Windows Explorer and run the “Install.exe” from the DVD.
Select a market and language for DDS-CAD and confirm with “OK”:
When selecting the option “Modify” you can select to install the mod-
ules “Crystal Report” and “Polysun Inside”:
After the restart you can insert the USB dongle in the computer. The
USB dongle will be automatically recognized; afterwards you can
launch DDS-CAD and update your dongle if required (see chapter 5).
After you have inserted the DVD, the installation will start automati-
cally. If the installation procedure does not start automatically, open
Windows Explorer and run the “Install.exe” from the DVD.
Select “Next”:
Network installation | 21
Enter the location to which the setup data should be copied:
At the location a copy of the DVD setup is created, which can be used
for installing the software on workstations in the network:
22 | Network installation
After completing the copy procedure select “Finish”:
Once the setup data has been copied to the destination folder, the
network setup dialog will be displayed again. To create the required
setup configuration for the workstations select “Record Setting”:
Network installation | 23
Select “Next”:
Enter your user name and company name and indicate for which us-
ers DDS-CAD should be installed:
24 | Network installation
Select the option for network installation and select “Next”:
Network installation | 25
The locations relate to the following questions:
• In which folder should the software be installed?
• Where should user data be stored (e.g. company logo, own products,
symbols, settings, etc)?
• In which folder should projects be stored?
• To copy the user folder from a previous version of DDS-CAD and spe-
cify its location.
If you select the setup type “School”, the locations for the program and
configuration files are proposed. You have the possibility to change
the locations in this dialog.
26 | Network installation
Select the setup type “Complete” for a full installation of DDS-CAD:
When you select the setup type “Custom” you can choose whether the
modules “Crystal Reports” and “Polysun Inside” have to be installed.
When deselecting the module “Crystal Report” DDS-CAD cannot cre-
ate reports (e.g. output of calculation results and parts lists). The mod-
ule “Polysun Inside” is used for calculating the yield of PV systems:
Network installation | 27
Select which shortcuts you would like to have installed and press
“Next”:
Click “Finish” to conclude the simulated setup process and close the
installation menu:
28 | Network installation
4.3 Run setup on workstations
Network installation | 29
After successfully completing the installation procedure please re-
start the computer:
30 | Network installation
5. Update Dongle
5.1 Local dongle
After the first start of DDS-CAD 10 the dialog “License check failure”
appears:
Enable the radio button next to “From Internet” and select “OK”:
Update Dongle | 31
Again, confirm with “OK”:
The network dongle must be removed from the server and can be
plugged into a computer running a local installation of DDS-CAD. To
update the network dongle, follow the procedure as described in the
previous section “Local Dongle”.
32 | Update Dongle
6. System requirements
Operating System
• Windows 7 Professional (SP1 or higher) 64 bit
• Windows 8 Professional 64 bit
• Windows 8.1 Professional 64 bit
Internet Browser
• Internet Explorer 7 or higher
CPU
• Equal AMD Dual Core CPU with 2,0 GHz or higher and SSE2
Memory (RAM): 4 GB
Display
• Resolution of 1280x1024 True Color
Keyboard: MS compatible
Other
• Internet connection for updates
• 1 x USB 2.0/3.0 port for dongle
System Requirements | 33
Notes
Notes
Data Design System AS
Øksnevad Næringspark
4353 Klepp Stasjon
Norway
info@dds-cad.com
www.dds-cad.com