Main Building Vehicle Parking

1 Ground + 1 Level Upper Floor 1 Parking for 3 cars, with shade facility
2 Minimum 3000 sqft 2 Loading and unloading area for a Van
3 15 feet of clearence from one side and walk way with interlocak tiles and green. 3 10 Bikes Parking Space
4 Gate entrance side to be with walk way and green.
Ground Floor Area SQFT Main Gate
Main Production Floor 900 1 25 feet Wide motorized
Milling machine & printers 150 2 Walk in entrance gate, to be independent gate.
Raw Material Storage 250
Quality Control 100 1 Guard Room, with wash room built in.
General Stores 60 2 Compressor Room, with 3 phase power
Finished Product Storage 90 3 Generator Room 15KVA
Reception / Lobby 300
Meeting Room 300 Septic Tanks
Note : False Celing with tiles, roof to celing clearance to be minimum 1 meter clearance space. Water Well & Water tank for storage of water
Flooring to be tiles Rain water drain and exit arrangements.
First Floor Area Walk way & Path to be around the building with inter lock bricks or concrete, rest area with mud for grass / plants
Research and Development 500 Building front elevation to be considered for Company Name / banner
Training Cenrer 600
Directors Office 300
Administration 200 CCTV
* Stair case on both sides, two stair case Access Control
Note : False Celing with tiles, roof to celing clearance to be minimum 1 meter clearance space. Fire Alarm System
Flooring to be tiles Fire Fighting Sprinklers, Hose reels & Fire pump, if the Law asks for. If not Portable Extinguishers are all required points.,
Roof Intercom - IP phones. Think of using Zycoo PABX, it has GSM & Land Line options, and several extensions & VOIP extensions so on the move you are in office extension.
IP Switch for complete office and extedned till the Recetional Building block

Access to roof available


For solar panels installation & Maintenance
Site Plans (1:500, 1:1000)
Recreational Area Building , behind main building indepedent block. Floor Distribution Plans/Sections/Elevations (1:100, 1:200)
1 Dining Room to accomodate 20 persons seating capacity Electrical Drawings

2 Kitchen area for full cooking facility Restrictions


3 Cook rest room with Bed facility, in the same Block with seperate entrance.
4 Common Bathrooms-2 , Male toilets- 3, Female Toilet -1, Urinals - 5 If the building is at the boundry of the land / No windows are allowed.
5 Billiards Table medium size, location space The mininum distance from the boundry of the land should be 7 feet to have windows.
6 Table Soccer medium size, location & Space
7 Sitting area for seats / chairs for atleast 10 persons.
8 Walk way to connect Main Building & Recreational Area Building. With shade to make better during raining season.