You are on page 1of 5

Drill Pipe Specification & Performance Data Sheet

3-1/2'', 13.30#, 0.368'', S135, EU, R2


Delta377 - 4.750'' x 2.563''
QT Item #: 11154

Tube / Pipe Body Specification Tubular Assembly Tube / Pipe Body Performance
OD: 3.500 in Adjusted Weight: 15.55 lbs/ft Inspection Class: Premium Class 80%

ID: 2.764 in Length (approximate): 30 - 32 ft Remaining Body Wall: 0.294 in

Wall Thickness: 0.368 in Box TJ Length (nominal): 17 in Tube Tensile: 381,870 lbs

Weight (nominal): 13.30 lbs/ft Pin TJ Length (nominal): 12 in Torsional Strength: 25,850 ft-lbs

Grade: S135 Fluid Displacement: 0.0057 bbls/ft Burst Capacity: 22,710 psi

Range: R2 Fluid Capacity w/ IPC: 0.0070 bbls/ft Collapse Capacity: 21,630 psi

Type of Upset: EU An oilfield barrel equals 42 US gallons.

Maximum Upset OD: 3.875 in

Notes: Notes:
-Dimensions, wall thickness, and tool joint lengths shown above are nominal if not otherwise stated. -Tube / Pipe body properties are calculated based on
-Values shown may vary with actual values due to OEM tolerances, rounding, and other factors. uniform OD and wall thickness.
-Capacity, Displacement, & Adjusted Weight are best estimates from the OEM and are based on pipe purchased at
95% RBW with longer than standard tool joints. Nominal thickness of IPC is .009" when applied.

Connection / Tool Joint Specification Connection Performance


Connection: Delta377 Thread Compound Friction Factor (FF): 1.0 FF 1.15 FF

OD: 4.750 in Extended Make-Up Torque¹: 22,800 26,220 ft-lbs

ID: 2.563 in Tension at Extended Make-Up Torque: 397,000 397,000 lbs

SMYS: 130 ksi Standard Max Make-Up Torque¹: (Recommended) 19,500 22,425 ft-lbs

Drift Size: 2.438 in Tension at Standard Make-Up Torque: 529,420 529,420 lbs

Elevator Taper: 18° Minimum Make-Up Torque: 16,300 18,745 ft-lbs

Notes: Tension at Minimum Make-Up Torque: 653,310 653,310 lbs


-Above dimensions are nominal.
-The following are registered trademarks of NOV-Grant
Torsional Strength: 32,530 37,410 ft-lbs
Prideco™: Delta™
-There is no published pressure rating for this The Standard Max Make-Up Torque based on the appropriate thread compound friction factor (FF) is recommended. MUTs
connection. lower than standard max should only be applied when MUT is limited by rig equipment or connection tensile capacity. MUT
values lower than Minimum MUT should never be used.

See OEM NOV-Grant Prideco™ bulletin on Extended MUTs (Standard Max MUT is 60% of connection torsional whereas Extended
MUT is 70%).

Adjust MUT values per the applied thread compound's FF greater than 1.0, without exceeding 1.15. Above values tabulated at 1.0
Elevator Shoulder Capacity and 1.15 FF.

-Refer to the attached OEM page(s) for capacities with ¹The Extended MUT is recommended when downhole torque and/or backoff is a concern due to string dynamics (stick-slip, rocking,
wear prior to using. etc.) and other conditions associated with long laterals, providing it is not limited by connection tensile capacity reduction due to higher
preload or rig equipment.

For combined loading of drill pipe, connection wear table, & elevator capacity figures, please see the attached page(s) provided by NOV-Grant Prideco™.

www.quailtools.com
Visit our website or download the Quail Tools Tubular & BOP Specification App for the latest updates and specifications!
The technical information contained herein, including the product Specification / Performance sheets and other attached documents, have been generated from material provided by the manufacturer where available. It is for reference only and should not be construed as a
recommendation. The user is fully responsible for the accuracy and suitability of use of all technical information. Quail Tools cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended. Assembly
properties are based on uniform OD and wall thickness. No safety factor is applied. The information provided for various wear conditions (remaining body wall) is for information only and does not represent or imply acceptable operating limits. It is the responsibility of the
customer and/or end user to determine the appropriate performance ratings, acceptable use of the product, maintain safe operational practices, and to apply a prudent safety factor suitable for the application. The user should consider all field conditions along with combined
factors which may affect the final string design used in the field. For API connections that have different pin and box ID’s, tool joint ID refers to the pin ID. Per the IADC drilling manual, it is recommended that drilling torque should not exceed 80% of MUT.
New Iberia, LA (337) 365-8154 Victoria, TX (361) 579-0244 Odessa, TX (432) 366-1491 Evanston, WY (307) 789-5860
Texarkana, TX (903) 838-1624 Williston, ND (701) 774-2280 Morgantown, WV (304) 212-5191
Houston, TX (281) 445-1777 * Denver, CO (303) 534-1873 * Ok. City/Tulsa, OK (918) 994-4695 * Dallas, TX (972) 661-1443 * San Antonio, TX (210) 822-4801 * Pittsburgh, PA (724) 916-4643

**Uncontrolled When Printed**


devind QT-DP 3.500 13.30 S Delta377 4.750 x 2.563 R2 80RBW Generated on: 4/28/2021
QT Item #: 11154

Drill Pipe Performance Sheet (1.0 FF)


1/8/2021

Combined Loading for Drill Pipe Connection Wear Table


Connection: Delta™ 377 4.75" x 2.563" (130 KSI SMYS ) Friction Factor: 1.0 Connection: Delta™ 377 4.75" x 2.563" (130 KSI SMYS ) Friction Factor: 1.0
Pipe: 3.5" OD 0.368" Wall Thickness S135 80% Inspection Class Tool Joint OD (in) Max MUT(ft-lbs) Min MUT(ft-lbs)
At Max MUT (19500 ft-lbs ) At Min MUT (16300 ft-lbs ) 4.75 19500 16300
Operational Assembly Max Operational Assembly Max 4.721 19500 16300
Torque(ft-lbs) Tension(lbs) Torque(ft-lbs) Tension(lbs) 4.692 19500 16300
0 381900 0 381900 4.664 19200 16000
900 381600 700 381700 4.635 18600 15500
1800 380900 1500 381200 4.606 18100 15100
2800 379600 2200 380500 4.577 17600 14600
3700 377900 2900 379500 4.548 17000 14200
4600 375800 3700 377900 4.519 16500 13800
5500 373100 4400 376300 4.491 16000 13300
6400 370000 5100 374400 4.462 15500 12900
7400 365900 5900 371800 4.433 15000 12500
8300 361700 6600 369200
9200 356900 7300 366300 Elevator Capacity
10100 351500 8100 362600 Elevator Bore Diameter: 3.96875" Elevator SMYS: 110,100 psi Box Taper Angle: 18 deg
11000 345600 8800 359100 Connection: Delta™ 377 3.5" 0.368" wall EU S135
12000 338200 9500 355100 Tool Joint OD (in.) Elevator Hoist Capacity (lbs)
12900 330900 10300 350200 No Wear 1/32" Wear Factor
13800 322900 11000 345600 4.75 589000 567500
14700 314100 11700 340500 4.721 565300 543700
15600 304500 12500 334300 4.692 541700 520100
16600 292700 13200 328300 4.664 519000 497500
17500 281100 13900 322000 4.635 495700 474100
4.606 472500 451000
4.577 449500 427900
The Technical information contained herein, including the product performance sheet and other attached documents, is for reference only and should not be

consider as a recommendation. The user is fully responsible for the accuracy and suitability of use of the technical information. NOV Grant Prideco cannot assume
4.548 426600 405100
responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended. Drill pipe assembly properties are calculated 4.519 403900 382300
based on uniform OD and wall thickness. No safety factor is applied. The information provided for various inspection classes and for various wear conditions 4.491 382000 360500
(remaining body wall) is for information only and does not represent or imply acceptable operating limits. It is the responsibility of the customer and the end user
4.462 359600 338100
to determine the appropriate performance ratings, acceptable use of the product, maintain safe operating practices, and to apply a prudent safety factor suitable

for the application. For API connections that have different pin and box IDs, tool joint ID refers to the pin ID. Per Chapter DS, Section DS-16 of the drilling manual,
4.433 337300 315800
it is recommended that drilling torque should not exceed 80% of MUT.

All references to any internal standards or specifications are per the current edition/revision at the point of manufacturing, unless otherwise stated. All references to any external standards or specifications are
per the current edition/revision at the original purchase order (P.O.) date, unless otherwise stated.

Grant Prideco L.P. | 10100 Houston Oaks Dr. | Houston, TX 77064 | www.nov.com/grantprideco
QT Item #: 11154

Drill Pipe Performance Sheet (1.15 FF)


1/8/2021

Combined Loading for Drill Pipe Connection Wear Table


Connection: Delta™ 377 4.75" x 2.563" (130 KSI SMYS ) Friction Factor: 1.15 Connection: Delta™ 377 4.75" x 2.563" (130 KSI SMYS ) Friction Factor: 1.15
Pipe: 3.5" OD 0.368" Wall Thickness S135 80% Inspection Class Tool Joint OD (in) Max MUT(ft-lbs) Min MUT(ft-lbs)
At Max MUT (22400 ft-lbs ) At Min MUT (18700 ft-lbs ) 4.75 22400 18700
Operational Assembly Max Operational Assembly Max 4.721 22400 18700
Torque(ft-lbs) Tension(lbs) Torque(ft-lbs) Tension(lbs) 4.692 22400 18700
0 381900 0 381900 4.664 22100 18400
1100 381500 900 381600 4.635 21400 17900
2200 380500 1700 381000 4.606 20800 17300
3200 378900 2600 379900 4.577 20200 16800
4300 376600 3400 378600 4.548 19600 16300
5400 373400 4300 376600 4.519 19000 15800
6500 369600 5100 374400 4.491 18400 15300
7600 365000 6000 371400 4.462 17800 14800
8600 360100 6800 368400 4.433 17200 14300
9700 354000 7700 364500
10800 346900 8500 360600 Elevator Capacity
11900 339000 9400 355700 Elevator Bore Diameter: 3.96875" Elevator SMYS: 110,100 psi Box Taper Angle: 18 deg
13000 330100 10200 350900 Connection: Delta™ 377 3.5" 0.368" wall EU S135
14000 321000 11100 344900 Tool Joint OD (in.) Elevator Hoist Capacity (lbs)
15100 309900 12000 338200 No Wear 1/32" Wear Factor
16200 297600 12800 331800 4.75 589000 567500
17300 283700 13700 323800 4.721 565300 543700
18400 268200 14500 316100 4.692 541700 520100
19400 252400 15400 306700 4.664 519000 497500
20500 232600 16200 297600 4.635 495700 474100
4.606 472500 451000
4.577 449500 427900
The Technical information contained herein, including the product performance sheet and other attached documents, is for reference only and should not be

consider as a recommendation. The user is fully responsible for the accuracy and suitability of use of the technical information. NOV Grant Prideco cannot assume
4.548 426600 405100
responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended. Drill pipe assembly properties are calculated 4.519 403900 382300
based on uniform OD and wall thickness. No safety factor is applied. The information provided for various inspection classes and for various wear conditions 4.491 382000 360500
(remaining body wall) is for information only and does not represent or imply acceptable operating limits. It is the responsibility of the customer and the end user
4.462 359600 338100
to determine the appropriate performance ratings, acceptable use of the product, maintain safe operating practices, and to apply a prudent safety factor suitable

for the application. For API connections that have different pin and box IDs, tool joint ID refers to the pin ID. Per Chapter DS, Section DS-16 of the drilling manual,
4.433 337300 315800
it is recommended that drilling torque should not exceed 80% of MUT.

All references to any internal standards or specifications are per the current edition/revision at the point of manufacturing, unless otherwise stated. All references to any external standards or specifications are
per the current edition/revision at the original purchase order (P.O.) date, unless otherwise stated.

Grant Prideco L.P. | 10100 Houston Oaks Dr. | Houston, TX 77064 | www.nov.com/grantprideco
QT Item #: 11154

Drill Pipe Performance Sheet (Extended, 1.0 FF)


1/21/2021

Combined Loading for Drill Pipe Connection Wear Table


Connection: Delta™ 377 4.75" x 2.563" (130 KSI SMYS ) Friction Factor: 1.0 Connection: Delta™ 377 4.75" x 2.563" (130 KSI SMYS ) Friction Factor: 1.0
Pipe: 3.5" OD 0.368" Wall Thickness S135 80% Inspection Class Tool Joint OD (in) Max MUT(ft-lbs) Min MUT(ft-lbs)
At Max MUT (22800 ft-lbs ) At Min MUT (16300 ft-lbs ) 4.75 22800 16300
Operational Assembly Max Operational Assembly Max 4.721 22800 16300
Torque(ft-lbs) Tension(lbs) Torque(ft-lbs) Tension(lbs) 4.692 22800 16300
0 381900 0 381900 4.664 22400 16000
1100 381500 700 381700 4.635 21700 15500
2200 380500 1500 381200 4.606 21100 15100
3300 378700 2200 380500 4.577 20500 14600
4500 376000 2900 379500 4.548 19900 14200
5600 372800 3700 377900 4.519 19300 13800
6700 368800 4400 376300 4.491 18700 13300
7800 364100 5100 374400 4.462 18100 12900
8900 358500 5900 371800 4.433 17500 12500
10000 352100 6600 369200
11200 344200 7300 366300 Elevator Capacity
12300 335900 8100 362600 Elevator Bore Diameter: 3.96875" Elevator SMYS: 110,100 psi Box Taper Angle: 18 deg
13400 326600 8800 359100 Connection: Delta™ 377 3.5" 0.368" wall EU S135
14500 316100 9500 355100 Tool Joint OD (in.) Elevator Hoist Capacity (lbs)
15600 304500 10300 350200 No Wear 1/32" Wear Factor
16700 291500 11000 345600 4.75 589000 567500
17800 276900 11700 340500 4.721 565300 543700
19000 258900 12500 334300 4.692 541700 520100
20100 240100 13200 328300 4.664 519000 497500
21200 218500 13900 322000 4.635 495700 474100
4.606 472500 451000
4.577 449500 427900
The Technical information contained herein, including the product performance sheet and other attached documents, is for reference only and should not be

consider as a recommendation. The user is fully responsible for the accuracy and suitability of use of the technical information. NOV Grant Prideco cannot assume
4.548 426600 405100
responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended. Drill pipe assembly properties are calculated 4.519 403900 382300
based on uniform OD and wall thickness. No safety factor is applied. The information provided for various inspection classes and for various wear conditions 4.491 382000 360500
(remaining body wall) is for information only and does not represent or imply acceptable operating limits. It is the responsibility of the customer and the end user
4.462 359600 338100
to determine the appropriate performance ratings, acceptable use of the product, maintain safe operating practices, and to apply a prudent safety factor suitable

for the application. For API connections that have different pin and box IDs, tool joint ID refers to the pin ID. Per Chapter DS, Section DS-16 of the drilling manual,
4.433 337300 315800
it is recommended that drilling torque should not exceed 80% of MUT.

All references to any internal standards or specifications are per the current edition/revision at the point of manufacturing, unless otherwise stated. All references to any external standards or specifications are
per the current edition/revision at the original purchase order (P.O.) date, unless otherwise stated.

Grant Prideco L.P. | 10100 Houston Oaks Dr. | Houston, TX 77064 | www.nov.com/grantprideco
QT Item #: 11154

Drill Pipe Performance Sheet (Extended, 1.15 FF)


1/21/2021

Combined Loading for Drill Pipe Connection Wear Table


Connection: Delta™ 377 4.75" x 2.563" (130 KSI SMYS ) Friction Factor: 1.15 Connection: Delta™ 377 4.75" x 2.563" (130 KSI SMYS ) Friction Factor: 1.15
Pipe: 3.5" OD 0.368" Wall Thickness S135 80% Inspection Class Tool Joint OD (in) Max MUT(ft-lbs) Min MUT(ft-lbs)
At Max MUT (26200 ft-lbs ) At Min MUT (18700 ft-lbs ) 4.75 26200 18700
Operational Assembly Max Operational Assembly Max 4.721 26200 18700
Torque(ft-lbs) Tension(lbs) Torque(ft-lbs) Tension(lbs) 4.692 26200 18700
0 381900 0 381900 4.664 25700 18400
1400 381300 900 381600 4.635 25000 17900
2800 379600 1700 381000 4.606 24300 17300
4100 377000 2600 379900 4.577 23600 16800
5500 373100 3400 378600 4.548 22900 16300
6900 368000 4300 376600 4.519 22100 15800
8300 361700 5100 374400 4.491 21500 15300
9600 354600 6000 371400 4.462 20800 14800
11000 345600 6800 368400 4.433 20100 14300
12400 335100 7700 364500
13800 322900 8500 360600 Elevator Capacity
15200 308900 9400 355700 Elevator Bore Diameter: 3.96875" Elevator SMYS: 110,100 psi Box Taper Angle: 18 deg
16500 294000 10200 350900 Connection: Delta™ 377 3.5" 0.368" wall EU S135
17900 275500 11100 344900 Tool Joint OD (in.) Elevator Hoist Capacity (lbs)
19300 254000 12000 338200 No Wear 1/32" Wear Factor
20700 228700 12800 331800 4.75 589000 567500
22100 198100 13700 323800 4.721 565300 543700
23400 162300 14500 316100 4.692 541700 520100
24800 107800 15400 306700 4.664 519000 497500
26189 0 16200 297600 4.635 495700 474100
4.606 472500 451000
4.577 449500 427900
The Technical information contained herein, including the product performance sheet and other attached documents, is for reference only and should not be

consider as a recommendation. The user is fully responsible for the accuracy and suitability of use of the technical information. NOV Grant Prideco cannot assume
4.548 426600 405100
responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended. Drill pipe assembly properties are calculated 4.519 403900 382300
based on uniform OD and wall thickness. No safety factor is applied. The information provided for various inspection classes and for various wear conditions 4.491 382000 360500
(remaining body wall) is for information only and does not represent or imply acceptable operating limits. It is the responsibility of the customer and the end user
4.462 359600 338100
to determine the appropriate performance ratings, acceptable use of the product, maintain safe operating practices, and to apply a prudent safety factor suitable

for the application. For API connections that have different pin and box IDs, tool joint ID refers to the pin ID. Per Chapter DS, Section DS-16 of the drilling manual,
4.433 337300 315800
it is recommended that drilling torque should not exceed 80% of MUT.

All references to any internal standards or specifications are per the current edition/revision at the point of manufacturing, unless otherwise stated. All references to any external standards or specifications are
per the current edition/revision at the original purchase order (P.O.) date, unless otherwise stated.

Grant Prideco L.P. | 10100 Houston Oaks Dr. | Houston, TX 77064 | www.nov.com/grantprideco

You might also like