M820-The Error of Important Data Cause Abnormality of LACT Board
M820-The Error of Important Data Cause Abnormality of LACT Board
board
No matter how strong optical power input the LACT card , output were always low power (-
40dbm) (measured by optical power meter), the board can not adjust attenuation , default
attenuation value is 1.70db. When try to return zero operation on the NMS , adjusting the
attenuation appeared error , The error message is as follows:
2, replace the LACT board to judge whether the LACT board is broken or not ;
3,check the card version and the NMS version whether they are mismatch or not ;
4, check the important data of the LACT whether the important data is incorrect .
Solution
1, Input 7dBm power signal to L ACT ,The “ LACT Power Adjustment” show -0.13dbm on U31 ,
but the actual output show -40dbm by optical power meter . After the operation of returning zero
, show error similarly . Exclude the disqualification possiblity of input signal
2, Replace the LACT with the one from other sites,the phenomenon is the same.
3, operate returning zero in E300 EMS,the phenomenon is the same.Exclude the possibility of
EMS.
4, check the LACT board important data , found the LACT board VOA type is MEMS . But the
important data of the LACT board were wrriten as mechanical type .So changed the important
data byte 55 and byte 56, the fualt was resolved.
The following are important data before and after the change:
0046A819FF0001EB7EFFD228DB7CFA01
00000202000006D606E6202042F5FFFF
42F5FFFF0352035A010000FFFFFF00FF
EB017800FFFF
0046A819FF0001EB7EFFD228DB7CFA01
00000202000006D606E6202042F5FFFF
42F5FFFF0352035A010000FFFFFF00FF
EB017800FFFF
Summary and Notes
The problem is the important data seting wrong in production. Both important data is completely
different.