Name of test: Testing of Coarse aggregate


Ref. No.: Letter dated: 19/04/2021
Name of Agency: Power Grid Corporation of India Limited
Name and address of test lab: Department of Civil Engineering, NIT.

TEST RESULTS
Sieve analysis

(i) Coarse aggregate (90 mm to 63 mm)


Sl.no. 125mm 90mm 63mm 45mm 22.4mm
1 100 94.21 16.54 2.04 0

(ii) Coarse aggregate (63 mm to 45 mm)


Sl.no. 125mm 90mm 63mm 45mm 22.4mm
1 - 100 95.23 17.89 1.54

(iii) Coarse aggregate (45 mm to 22.5 mm)


Sl.no. 125mm 90mm 63mm 45mm 22.4mm
1 - - 100 96.42 15.41
The sieve sizes used are as per the requirements given by the client, above mentioned reference

Parameters

Sl.no. Particulars Plasticity index Flakiness index (%) Impact test


(%)
1 Coarse aggregate (90 mm to 63 - - 14
mm)
2 Coarse aggregate (63 mm to 45 - - 15
mm)
3 Coarse aggregate (45 mm to 22.5 - - 14
mm)
4 Moorum (Binding Material) 5.23 - -

Remark: The test results are as per the Materials brought to the Laboratory of Civil Engineering Dept.