MAINTENANCE MANUAL
General Information Maintenance Checks
Carefully read and follow the instructions contained in this guide. Connector Check
The purpose of this guide is to illustrate the actions that should be performed periodically on Midstream floodlights in Perform a visual inspection on of all the connectors, ensuring
order to provide the optimal working conditions in every environment. that every connector is secured and the grommets are still in
their original mounting positions, preventing water and dust
During wiring maintenance keep the wiring diagram of the LED luminaire model close at hand as well as the installation
from entering the connector.
manual.
Check that the cables are not under tension throughout the
installation nor have any sharp bends as instructed in the
installation manual.
If the control system is not in use, check that the cap on the
control outlet is firmly tightened.
If maintenance is needed on connectors/wires If the luminaire has to be taken down make sure
disconnect the electrical supply power before it is placed on a soft and non abrasive surface
Mounting screw and safety cable check
commencing the maintenance. Failure to do so and the lenses are not directly placed on the
could result in serious injury or death. ground. The Luminaire must not be switched Check every mounting point, ensuring that every screw is
on when laying it on the ground with the optics tightened.
facing down as they could be damaged. Check the safety cable and carabiner hook to ensure they are
secure.