You are on page 1of 2

Proposed 36 Classrooms Boy's Basic Education School (5-9) At Barka (Sawadi), Wilayat Barka In Batinah South Governorate

E40 Super Structure Fire Alarm Ditto No 1.00


Works Heat detector point
Fire Alarm
Installation
E41 Super Structure Fire Alarm Ditto No 2.00
Works Alarm Bell point
Fire Alarm
Installation
E42 Super Structure Fire Alarm Heat detector No 1.00
Works Accessories
Fire Alarm
Installation
E43 Super Structure Fire Alarm Break glass unit No 2.00
Works Accessories
Fire Alarm
Installation
E44 Super Structure Fire Alarm 150 mm dia. Alarm bell No 2.00
Works Accessories
Fire Alarm
Installation
E45 Super Structure Television Cable and conduit to TV point in No 2.00
Works System concealed installation from satellite
Electrical
Installation
E46 Super Structure Television Flush mounted TV / Satellite outlet No 2.00
Works System
Electrical
Installation
E47 Super Structure Computer Cable and conduits to RJ 45 No 3.00
Works System (Category 6A) dual socket outlet
Electrical
Installation

Page 28 Bill no 03 (Guard Driver Room)


Proposed 36 Classrooms Boy's Basic Education School (5-9) At Barka (Sawadi), Wilayat Barka In Batinah South Governorate
E48 Super Structure Computer Accessories - RJ 45 (Category 6A) No 3.00
Works System dual socket outlet
Electrical
Installation
E49 Super Structure Earthing System Earthing system including 16 mm dia. No 2.00
Works high conductivity solid copper rod
Electrical electrodes with drive head assemblies
Installation and Earthing clamps for earth pits,
Earthing of exposed pipe work,
sanitary fittings and equipment all as
required including 300 x 300 x 400
mm deep internally earth pit, earth
wires as per specification and
drawings complete with 300 mm x
300 mm heavy duty double seal
ductile iron cover and frame.
E50 Super Structure Sundries Allow for builders work in Item 1.00
Works connection with electrical installation
Electrical including holes, chases, sleeves,
Installation ducts, cable tray trucking, panel
backboards or formwork, supports,
access panels, cover plates etc.
E51 Super Structure Sundries Allow for incidental works such as co- Item 1.00
Works ordination with other engineering
Electrical installations.
Installation
E52 Super Structure Sundries Allow to identification labels, charts Item 1.00
Works etc.
Electrical
Installation

Page 29 Bill no 03 (Guard Driver Room)