You are on page 1of 3

TANK, API-650/653 Analysis COADE, Inc.

@1994-2007 Page 1 of 3
Licensed To: PAKISTAN REFINERY LTD. (PRL) ID: 20860
Job: Tank nadeem ate: 05/15/12 Time: 14:16:49 Ver: 3.00

WIND INFORMATION
API-650 10th Edition, Addendum 4, Dec. 2005

Wind Velocity ............................(mph ) 120.00


Velocity Factor ...................................... 1.0000
Wind Pressure ............................(lb./sq.in.) 0.24971
Area Exposed to Wind .....................(ft. **2) 7920.0
Sect 3.9.7.1 Wind Moment on Tank .........(ft.lb. ) 0.93980E+07
Wind Shear Force Acting on Tank ..........(lb. ) 0.28479E+06

MATERIAL PROPERTY INFORMATION


Wind Girder Height Reduction Factor .................. 1.0000

The following material properties have been modified in


accordance with API-650 (and API-653 where applicable).

Course Material Design Test App M


Number Name Stress (Sd) Stress (St) Reduction
(lb./sq.in.) (lb./sq.in.)
1 A-516,65 23300. 26300. 1.0000
2 A-516,65 23300. 26300. 1.0000
3 A-516,65 23300. 26300. 1.0000
4 A-516,65 23300. 26300. 1.0000
5 A-516,65 23300. 26300. 1.0000
6 A-516,65 23300. 26300. 1.0000
7 A-516,65 23300. 26300. 1.0000
8 A-516,65 23300. 26300. 1.0000
9 A-516,65 23300. 26300. 1.0000
10 A-516,65 23300. 26300. 1.0000
11 A-516,65 23300. 26300. 1.0000

SHELL COURSE THICKNESS DATA - One Foot Method


Thickness Values for Three Cases MIN TEMP
COURSE DESIGN TEST USER (deg F )
(in. ) (in. ) (in. ) Status

1 0.81234 0.69992 0.82677 26.3 NA


2 0.74244 0.62875 0.74803 23.9 NA
3 0.60754 0.55757 0.62992 19.3 NA
4 0.53764 0.48639 0.57087 16.9 NA
5 0.46774 0.41521 0.49213 14.5 NA
6 0.39784 0.34403 0.41339 12.1 NA
7 0.32795 0.31250 0.33465 9.7 NA
8 0.31250 0.31250 0.33465 9.1 NA
9 0.31250 0.31250 0.33465 9.1 NA
10 0.31250 0.31250 0.33465 9.1 NA
11 0.31250 0.31250 0.33465 9.1 NA

SHELL COURSE ALLOWED FLUID HEIGHTS


Fluid Heights for Three Cases
COURSE DESIGN TEST REQUIRED
(ft. ) (ft. ) (ft. )

1 60.000 69.476 60.000


2 54.000 63.584 54.000
3 48.000 52.212 48.000
4 42.000 46.320 42.000
5 36.000 40.428 36.000
6 30.000 34.536 30.000
7 24.000 28.644 24.000
8 22.674 27.342 18.000
9 22.674 27.342 12.000
10 22.674 27.342 6.0000
TANK, API-650/653 Analysis COADE, Inc. @1994-2007 Page 2 of 3
Licensed To: PAKISTAN REFINERY LTD. (PRL) ID: 20860
Job: Tank nadeem ate: 05/15/12 Time: 14:16:49 Ver: 3.00

11 22.674 27.342 0.00000

Maximum allowed fluid height of entire tank for:


Design Thickness Case .................(ft. ) 60.000
Test Thickness Case .................(ft. ) 64.212
Required fluid height .................(ft. ) 60.000

BASE PLATE DETAILS - SHELL WEIGHT & CENTER OF GRAVITY


Annular Base Plate Thickness .............(in. ) 0.37500
(from API-650 Table 3-1)
Annular Base Plate Width per 3.5.2 .......(in. ) 26.812
( 2 + ThkCrs1 + max[ 24, (390tb / sqrt(HG))] )
Weight of Shell + Nozzles ................(lb. ) 0.47513E+06
Total Weight of all Nozzles ..............(lb. ) 0.00000
Center of Gravity (Shell+Nozzles) ........(ft. ) 26.358

WIND OVERTURNING STABILITY CHECK


Corroded Shell Weight + %Roof - Uplift ...(lb. ) 0.40215E+06
wa .......................................(lb./in. ) 140.99
Mw - moment due to wind (hor+ver) press ..(ft.lb. ) 0.93980E+07
Mpi - moment due to internal pressure ....(ft.lb. ) 0.00000
Mf - moment due to tank liquid ...........(ft.lb. ) 0.38269E+08
Mdl - moment due to shell & roof .........(ft.lb. ) 0.24129E+08
Anchors not needed for Sect. 3.11

WIND GIRDER INFORMATION


For "open top" tanks ...
Required Section Modulus, Top Girder ...(in. **3) 95.040
Table 3-20 Detail, B value .............(in. ) e 28.00
Table 3-20 Shape name (if applicable)............... DETAIL_E

Maximum Height of Unstiffened Shell ......(ft. ) 24.917

WIND GIRDER - TRANSFORMED SECTION METHOD


Number of Intermediate Girders Reqd .................. 1

Note, in the following table, the "DIST" values are the


distances between the wind girders. These values are not
the distance down from the top of the tank!

---TRANSFORMED--- ACTUAL SECTION --- TABLE 3-20 ---


GIRDER HEIGHT DIST. DIST. MODULUS(in. **3) DETAIL B SHAPE
(ft. ) (ft. ) (ft. )
1 38.7126 19.3563 19.3563 27.873 d 0.00 6x4x.375

--- Actual Distance of Intermediate Wind Girders from Top of Tank ---
GIRDER DISTANCE (ft. )
1 19.3563

WEIGHT SUMMARY
--------------
Shell (Corroded) .............................(lb.): 402150.
Shell (Non-Corroded) .........................(lb.): 475126.
Annular Base Plate ...........................(lb.): 0.
Bottom Plate .................................(lb.): 0.
Nozzles ......................................(lb.): 0.
Roof Plates ..................................(lb.): 0.
Roof Framing/Structure .......................(lb.): 0.
Shell Attachments ............................(lb.): 0.
Insulation ...................................(lb.): 0.
Operating Fluid ..............................(lb.): 36814148.
Water Weight .................................(lb.): 42315100.
TANK, API-650/653 Analysis COADE, Inc. @1994-2007 Page 3 of 3
Licensed To: PAKISTAN REFINERY LTD. (PRL) ID: 20860
Job: Tank nadeem ate: 05/15/12 Time: 14:16:49 Ver: 3.00

Operating Weight (Non-Corroded) ..............(lb.): 37289276.


Test Weight (Non-Corroded) ...................(lb.): 42790228.
Empty Weight (Non-Corroded) ..................(lb.): 475126.

You might also like