You are on page 1of 1

BUILDING CODE REQUIREMENTS

14'-6 1/2"
a. The construction shall not restrict a fivefoot clear i. For existing pool on site, provide an
and unobstructed access to any alarm for doors to the dwelling that form a 5'-0" 6'-5" 3'-7 1/2" 5'-11" 5'-0" 7 3/4" 4'-8" 7 3/4" 12'-4" 7 3/4"
water or power distribution facilities (Power part of the pool enclosure. The alarm shall
poles, pull-boxes, transformers, vaults, sound continuously for a min. of 30 2
pumps, valves, meters, appurtenances, seconds when the door is opened. It shall
etc.) or to the location of the hook-up. The automatically reset and be equipped with a 2 3
construction shall not be within ten feet of manual means to deactivate (for 15 secs.
any power lines-whether or not the lines max.) for a single opening. The
are located on the property. Failure to deactivation switch shall be at least 54"
comply may cause construction delays above the floor. (6109 of LABC)
and/or additional expenses.
j. For existing pool on site, provide antiÐ
b. An approved Seismic Gas Shutoff Valve entrapment cover meeting the current
will be installed on the fuel gas line on the ASTM or ASME for the suction outlets of RANGE

2'-0"
2'-6"

downstream side of the utility meter and be the swimming pool, toddler pool and spa
rigidly connected to the exterior of the for single family dwellings per Assembly Bill
building or structure containing the fuel gas (AB) No. 2977. (3162B)
piping. (Per Ordinance 170,158) (Separate
plumbing permit is required). k. Automatic garage door openers, if
provided, shall be listed in accordance with 2'-11" 2'-6" 2'-11"
c. Plumbing fixtures are required to be UL 325. (R309.4) 1 1

A
7'-0"
connected to a sanitary sewer or to an
6'-1"

HOOD DW

2'-0"
2
6'-8 1/2"

approved sewage disposal system l. Smoke detectors shall be provided for all ABOVE
(R306.3). dwelling units intended for human 3 3
occupancy, where a permit is required for 1
d. Kitchen sinks, lavatories, bathtubs,
showers, bidets, laundry tubs and washing
alterations, repairs, or additions. (R314.2)
2
3'-7"

machine outlets shall be provided with hot m. Where a permit is required for alterations, 3 3
and cold water and connected to an repairs or additions, existing dwellings or
1 AA

architect
approved water supply (R306.4). sleeping units that have attached garages
or fuel-burning appliances shall be 2
A6.2

2'-8"
e. Bathtub and shower floors, walls above provided with a carbon monoxide alarm in 2'-5" SINK
bathtubs with a showerhead, and shower accordance with Section R315.2. Carbon
1

2'-8"
compartments shall be finished with a monoxide alarms shall only be required in
D BB
nonabsorbent surface. Such wall surfaces the specific dwelling unit or sleeping unit for
shall extend to a height of not less than 6 which the permit was obtained. (R315.2.) M A6.1

13'-8 1/2"
feet above the floor (R307.2). A
MASTER BEDROOM
n. Every space intended for human
f. Provide ultra-low flush water closets for occupancy shall be provided with natural

architect stamp
KITCHEN
all new construction. Existing shower light by means of exterior glazed openings 2'-6 1/2" 2'-1 1/4" 3'-1" 1'-8"
heads and toilets must be adapted for low in accordance with Section R303.1 or shall
water consumption. be provided with artificial light that is F2
2'-8"

adequate to provide an average

3'-0"
REFRIG./ F1
g. Unit Skylights shall be labeled by a LA City illumination of 6 foot-candles over the area D
1 FREEZER
C

3'-0"
Approved Labeling Agency. Such label of the room at a height of 30 inches above
4'-10"

ideas,

property and copyright of the

scaled
be used by any other person

dimensional discrepancy shall


written

dimensions and shall be

the ARCHITECT prior to the


take
plans

and specifications are the


indicated by these drawings

for any use whatsoever without

verified at the job site. any


be used on any other work nor
ARCHITECT and shall neither

be brought to the attention of


shall state the approved labeling agency the floor level. (R303.1)
name, product designation and A6.2 A4.2

commencement of work.
performance grade rating. (Research o. A copy of the evaluation report and/or

and

shall
5"

over
written permission.
Report not required). (R308.6.9) conditions of listing shall be made available
L

designs,
6'-2 1/2"
at the job site
h. Water heater must be strapped to wall. B

arrangements
MASTER BATH

precedence
dimensions
(Sec. 507.3, LAPC)

copyright
F4 4

all
3'-1 1/2"

3'-0"
5

2'-8"
2'-8 1/2"
K
2
G
F 5'-4"
2'-0"
6
2 2'-9" 2'-11 1/2" 11'-8 1/2"
2'-5 1/4" 10'-4"
BATH

2'-6"
J

4'-0"
F5
5'-0"

5'-4 1/2"

6'-9 1/2" 6'-1 1/2" 2 5'-2"


5'-4 1/2" 15'-6"
A6.2
D

9 1/4"
C C
2
B A6.1

2'-8"
5'-3"
C
D

consultant
3'-10 1/2"

A4.2
LIVING ROOM
1'-10" 2'-0 1/4" 1'-6" 2'-6" 2'-11 3/4"
7
F2

11'-10 7/8"
18'-10"

10'-5 1/2"
E
3

South Hills Residence


4'-11"
A6.1
3 2

7'-5 5/8"
2'-9"
A6.2
2 H
OFFICE
13'-4"

Los Angeles, CA 90049


C

5'-0"
F3
BEDROOM 2

1802 South Hills Dr.


1'-4 1/2" 2'-6" 4'-6"
F6

James & Carol Smith


1 I I 1

OWNER:
project title
3 14'-7 1/2" 6'-4 1/4" 6'-0" 5'-6"
A6.2

pm/pic
17'-3 3/4" 17'-10 1/4"
9'-7"

XX
11'-5 3/4"

-
-
-
-
-
-
-
-
-
-
-
2 BEDROOM 3

drawn by
35'-9 1/2"
F7

XX
-
-
-
-
-
-
-
-
-
-
-
2 3

DESIGN DEVELOPMENT SUBMITTAL 90%


8'-11 3/4"
B A

DECONSTRUCTION & RE-USE EST.


PLAN CHECK FIRST SUBMISSION
A4.1 A4.1

PLAN CHECK CORRECTIONS


CONSTRUCTION PLAN LEGEND CONSTRUCTION KEYED NOTES

issue description

PERMIT SET
REVISION 1
1 (N) DOOR @ (E) EXPANDED HEADER; INFILL 6 LINE OF VAULTED CEILING SHOWN
WINDOW KEY; SURROUND AS REQ. DASHED

-
-
-
-
-
-
1
SEE WINDOW SCHEDULE ON SHEET A2.3a
I

NOV. 11, 2020

AUG. 10, 2021

APRIL 7, 2022
JAN. 26, 2021

NOV. 1, 2021
JAN 27, 2022
2 SHELF & CLOSET ROD ABOVE DASHED 7 (N) SKYLIGHT
ROOM FINISH KEY;
F1 SEE ROOM FINISH SCHEDULE ON SHEET A2.4a
2

date

-
-
-
-
-
-
3'-0 3/4" 6'-0" 3'-0 3/4"
3 (N) WINDOW IN (E) FRAMING 8 MAXIMUM 25% OPENING AREA PER

job #
1412
A DOOR KEY; T-R302.1(1); SEE A3.01 FOR CALCS
13'-5"
SEE ROOM FINISH SCHEDULE ON SHEET A2.3a Ref. North
4 KITCHEN COUNTER/CABINET ISLAND REVISED PLAN
REVISED PLAN 1 1

title
5 (N) WASHER/ DRYER - VENT THRU FLOOR TO EXT 0 1 2 4
A2.1
A2.1
1/2" = 1'-0"

sheet

You might also like