WHAT IS SWITCHGEAR
Switchgear is the combination of electrical
disconnect switches, fuses or circuit breakers used
to control, protect and isolate electrical
equipment.
ELECTRICAL POWER
Switchgear is used both to de-energize
equipment to allow work to be done and to
Switchgear clear faults downstream.
❑ Isolation:
❑ Protection:
CAREER PATH
SUPPLIERS BANELBUILDERS
EGYPT
MARKET
EGYPT
Assembling of enclosures
WORK FLOW
TECHNICAL OFFER
1
DESIGN DRWINGS
AND DOCUMENTS TENDER ENGINEER
FINANCIAL OFFER
SURFACE FREE
MOUNTED STAND
PANELS PANELS
Modular
Fishpone
WHAT IS LV SWITCHGEAR
low voltage
switch gear
FREE-STAND
PANEL
CONSTRUCTION
Cubicle
construction
BODY
ROOF
TOP
PANEL
REAR MOUNTING
PANEL PLATE
SUPPORTS
SIDE
PANEL
BASE
BOTTOM
PANEL
PLINTH
Schneider
Blockset Prisma
ABB
MNS
FUNCTIONAL
DEVICE
❑ Isolation:
❑ Control:
❑ Protection:
CONTROL DEVICES
◼ Switching on and off
MOTOR
CONTROL DEVICES
CONTACTORS
solenoid operated switching device, capable of making, carrying and breaking currents
under normal circuit conditions including operating overload conditions .
❑ Function: control
- two-position device (open / closed).
- commonly controlled remotely by on-off pushbuttons ,
- It does not provide protection for the circuit it controls.
- It does not provide isolation.
C
CONTROL DEVICES
CONTROL DEVICES
IMPULSE RELAY
LOAD-BREAK
SWITCH
ISOLATION DEVICES
LOAD-BREAK
SWITCH
Mechanical switching device which complies with the isolating
function. It can withstand normal operating current, In case of
fault current , withstanding is for very short time.
❑Function: isolation
- two-position device (open / closed).
- generally manually-operated,
- lockable,
ISOLATION DEVICES
A
B
PROTECTION DEVICES
t (s)
0
60 A I (A)
overloads
PROTECTION DEVICES
Overload protection
bimetal strip
t (s)
X (s) Y
0
60 A 120 A I (A)
PROTECTION DEVICES
Short-circuit protection
t (s)
Y
X (s)
I (A)
250 A
3000 A
PROTECTION DEVICES
Earth leakage protection
PROTECTION DEVICES
CIRCUIT
BREAKER
A circuit breaker is an automatically operated
electrical switch designed to protect an
electrical circuit from damage caused by excess
current from an overload or short circuit.
❑ Function:
- protection - control - isolation.
MCCB
Molded Case Circuit Breaker
Molded case
circuit breaker
20A – 1600A
TRIP UNITS
The trip unit is the “brain” of the circuit breaker. It consists of trip units
components that will automatically trip the circuit breaker when it
senses an overload or short circuit. The tripper bar is moved by a
manual “PUSH TO TRIP” button, a thermal overcurrent sensing
element or an electromagnet.
thermal / magnetic Electronic (static)
trip units trip units
Tmax
NSX
Masterpact mtz
FUSES
A fuse consists of a metal strip or wire fuse element, of small
cross-section compared to the circuit conductors, mounted
between a pair of electrical terminals, and (usually) enclosed by
a non-combustible housing. The fuse is arranged in series to
carry all the current passing through the protected circuit.
BMS
Building management
system
Manual control
Molded case
CB
What is the Main Function for the SHUNT TRIP ?
shunt trip
Siemens
Schneider ABB STL
MX SOR-C
The MN release opens the circuit breaker when its supply voltage drops to a
value below 35 % of its rated voltage Un.
Under voltage tripping, combined with an emergency-off button, provides fail-
safe tripping.
Motor
mechanism
Schneider ABB Siemens
What is the Main Function for the Auxiliary and alarm switches?
The auxiliary and alarm switches can be very simply snapped into place and
connected up in accessories compartments provided on the front panel of the
unit to the left and right of the handle.
All auxiliary and alarm switches are designed as changeover contacts and
therefore provide a high degree of flexibility for planning and installation
purposes.
Auxiliary
switches
BMS
Building management system
Shunt trip
Sensitive
LOAD load
BMS
Building management system
LOAD
ACB
accessories
SHUNT TRIPS , UVR AND CLOSING COIL
Cubicle
construction
Out going CB
Vertical BB
Compartment
Horizontal BB
Compartment
Cubicle
construction
the main
4 compartments
Functional
Cable Compartment comp. Vertical bus bar comp.
Breaker comp. Vertical bus bar comp.
Cubicle
construction
the main incomer CB
Cubicle
component
(Horizontal/Main) BB Compartment
(Vertical/Distribution) BB Compartment
Functional unit –Withdrwable
3
Functional Unit
withdraw able
Functional unit – Fixed
3
Functional Unit
fixed
Cubicle
construction
Corner cell
800x800 mm
Classification
We can classify LVSWG according to :
1-Feeder access (Top-Bottom).
2- Location (indoor – outdoor).
3-IP (20-31-42-54).
4-Forms (1-2-3-4).
INCOMER
BB
INCEOMER FEEDER
TOP
INCEOMER FEEDER
BUTTOM
5
IP
index protection
6
forms
6
forms
6
forms
6
forms
6
forms
6
forms
6
forms
How to determine
switch gear dimensions
70 cm 20 cm 70 cm 40 cm
Front
access
Cable compartment
Vertical BB
200 cm Main Functional
CB comp.
70 cm 130 cm
60 cm
Front
access
200 cm
70 cm 20 cm 70 cm
Rear
access
Vertical BB
200 cm Main Functional
CB comp.
90 cm 90 cm
60 cm 30cm
Rear
access
Cable compartment
200 cm
90cm
Horizontal BB
10 mod.
VERTICAL
Function unit
MODULE 30 mod.
70cm
EXAMPLE
1 CUBICAL 10
7
7
10
1 CUBICAL
10 MODULE
7 MODULE 7 MODULE
CUBICAL 1 VERTICAL CUBICAL 2 CABLE VERTICAL CABLE
BB COMP BB COMP
200 cm
70 cm
Vertical BB
20 cm
70 cm
Cable compartment
Vertical BB
40 cm 20 cm 70 cm
Cable compartment
40 cm