You are on page 1of 2

5/4/23, 11:19 AM Typhon Group - EASI System

Survey: "3D- CRT Photon Planning Competency Evaluation"


Reviewer: Clinical Instructors (BUMP, Ed)
Reviewee: Students (Monago, Ryan)
Survey Period: 5/1/2023
Completed: 5/1/2023 3:44:13 PM CT

1. Select the external beam photon planning competency from the drop down menu below:

Lung

2. If Other competency, please specify the type here:

3D conformal lung 3/10/23

3. Please assign each task a score of Satisfactory or Unsatisfactory.


Unsatisfactory in any essential task constitutes competency failure.
The student will repeat the competency at a later date.

Discusses the plan prescription with the physician. Satisfactory [2 pts]

Loads the patient imaging studies into the planning computer. Satisfactory [2 pts]

Contours the appropriate anatomy on the image data set. Satisfactory [2 pts]
Additional Comments:  This was a good case for contouring
normal structures within the thorax region and Ryan handled
this well!

Successfully places the isocenter using simulation data. Satisfactory [2 pts]

Correctly generates plan using blocks, wedges, segmented Satisfactory [2 pts]


fields. Additional Comments:  Excellent job handling the
inhomogeneities within the treatment area that included lung
and mediastinum!

Generates plan with appropriate weighting. Satisfactory [2 pts]

Generates plan with appropriate energies. Satisfactory [2 pts]


Additional Comments:  Understands important issues within
the lung in relation to energies chosen- pros and cons of higher
energies, etc.

Accurately generates/evaluates plan DVH or composite DVH Satisfactory [2 pts]


(for correct # of fractions).

Communicates effectively with physician for plan review and Satisfactory [2 pts]
makes changes as requested.

Exports/Prints appropriate plan data. N/A

Performs a verification calculation for plan MU settings. N/A

Enters correct parameters for the patient chart. Satisfactory [2 pts]

Performs pretreatment checks/calculations. Satisfactory [2 pts]

Utilizes respiratory gating information to determine field N/A


parameters.

Observes patient treatment. N/A

Mean: 2.00 of 2  Points: 22  Score: 100.0%

about:blank 1/2
5/4/23, 11:19 AM Typhon Group - EASI System
4. Overall rating:

Pass [2 pts]

Mean: 2.00 of 2   Points: 2  Score: 100.0%

Total points for all rating scale questions: 24


Mean percentage score for all rating scale questions: 100.0%
(Each main question equally weighted)
Responses as of 5/4/2023 11:16:43 AM CT