Design of Standard Rate

Trickling Filter
Basic Definitions
BOD Biological Oxygen Demand
Stabilize
Oxygen Waste Organic Matter

BOD Measured
by PPM Particle Per Million 𝑔𝑚/𝑚3

Inlet BOD Total BOD Before Primary Treatment


Oulet BOD Total BOD After Secondary Treatment
𝐵𝑂𝐷𝑖
𝐵𝑂𝐷𝑜
Basic Definitions
𝐵𝑂𝐷𝑖 Inlet BOD
𝐵𝑂𝐷𝑜 Outlet BOD
𝐵𝑂𝐷𝑝 Primary Treatment BOD
𝐵𝑂𝐷𝑠 Secondary Treatment BOD
3
𝐿 Allowable BOD Loading 𝐿 = 120𝑘𝑔/1000𝑚 /𝑑𝑎𝑦
120 𝑘𝑔/𝑑𝑎𝑦 1000 𝑚3
𝐵𝑂𝐷𝑡 Actual BOD Loading
Sewage 1000 𝑚3 𝑑𝑎𝑦
𝐵𝑂𝐷 300 𝑔𝑚 𝑚3
𝐵𝑂𝐷𝑡 𝑥 𝑔𝑚 𝑑𝑎𝑦
Problem
Given:
𝑃 = 200,000 𝑐𝑎𝑝𝑖𝑡𝑎
𝑄𝑎𝑣𝑔−𝑠 = 200 𝑙/𝑐/𝑑𝑎𝑦.
𝐼𝑛𝑙𝑒𝑡 𝐵𝑂𝐷 = 300 𝑝𝑝𝑚
3
𝐴𝑙𝑙𝑜𝑤𝑎𝑏𝑙𝑒 𝐿𝑜𝑎𝑑 = 120 𝑘𝑔/1000𝑚 /𝑑𝑎𝑦
Solution

Flow:
𝑄𝑚𝑥 = 200 × 200,000 = 70867.37 𝑚3 Τ𝑑 𝑎𝑦

= 0.82 𝑚3 Τ𝑠
BOD:
3
𝐵𝑂𝐷𝑖 = 300 𝑝𝑝𝑚 = 300 𝑔𝑚/𝑚
𝐵𝑂𝐷𝑝 = 300 × 0.30 = 90 𝑝𝑝𝑚
𝐵𝑂𝐷𝑠 = 300 × 0.70 = 210 𝑝𝑝𝑚
Solution
3
Sewage 70,867.37𝑚 𝑑𝑎𝑦
3
𝐵𝑂𝐷𝑠 210 𝑔𝑚 𝑚
𝐵𝑂𝐷𝑡 𝑥 𝑔𝑚 𝑑𝑎𝑦

Actual BOD:
𝐵𝑂𝐷𝑡 = 210 × 70,867.37 = 14,882,147.7 𝑔𝑚/𝑑𝑎𝑦
𝑔𝑚/𝑚3 × 𝑚3 /𝑑𝑎𝑦 = 𝑔𝑚/𝑑𝑎𝑦
𝐵𝑂𝐷𝑡 = 14,882,147.7 /1000 = 14,882.1477 𝑘𝑔/𝑑𝑎𝑦
Solution
Capacity
3
120 𝑘𝑔/𝑑𝑎𝑦 1000 𝑚
14,882.1477 𝑘𝑔/𝑑𝑎𝑦 𝐶𝑡 𝑚3

𝐶𝑡 = 14,882.1477 × 1000/120
3
𝐶𝑡 = 124,017.9 𝑚

3
𝐶𝑡 = 𝐵𝑂𝐷𝑡 / 𝐿 = = 124,017.9 𝑚
120/1000
Solution
Area & Diameter
𝐶𝑡 = 124,017.9 𝑚3
𝑑 = 2.5 𝑚 2: 3 𝑚
𝐴𝑡 = 𝐶𝑡 /𝑑
𝐴𝑡 = 124,017.9/2.5 = 49,607.159 𝑚2
Take the diameter of one filter = 40 m
𝐴1 = × 402 = 1256.637 𝑚2
Solution
Area & Diameter
𝑛 = 𝐴𝑡 /𝐴1
𝑛 = 49,607.159 /1256.637 = 39.47
Take 40 filters

𝐴1−𝑎𝑐𝑡 = 49,607.159/40 = 1240.18 𝑚2

𝜙𝑎𝑐𝑡 = = 39.737 ≈ 39.75 𝑚


Solution
Hydraulic Loading
ℎ𝑦𝑑𝑟𝑎𝑢𝑙𝑖𝑐 𝑙𝑜𝑎𝑑𝑖𝑛𝑔 = = 70,867.37 /49,607.159

ℎ𝑦𝑑𝑟𝑎𝑢𝑙𝑖𝑐 𝑙𝑜𝑎𝑑𝑖𝑛𝑔 = 1.4285 𝑚3 /𝑚2 /𝑑𝑎𝑦


3 2
1: 3 𝑚 /𝑚 /𝑑𝑎𝑦 𝑂𝐾
Solution
Efficiency
𝐸𝑝 = 30 %

𝐸𝑠 = L = 120 𝑘𝑔/1000𝑚3 /𝑑𝑎𝑦


𝑅=1

𝐸𝑠 = = 86.73%
Solution
Outlet BOD
𝐵𝑂𝐷𝑜 = 𝐵𝑂𝐷𝑠 × (1 − 𝐸𝑠 )
𝐵𝑂𝐷𝑜 = 210 × (1 − 0.8673 ) =27.867 𝑝𝑝𝑚
Finally, Total Efficiency
300 − 27.867
𝐸𝑡 = = 0.90711 = 90.711%
300