You are on page 1of 4

BEAM DESIGN

Beam Mark : (see highlighted members below)


Code : NSCP 2015
Staad Members : (see highlighted members below)

Beam Parameters
b = 250 mm fc' = 21 mPa ln = 5000 mm
h = 275 mm fyl = 276 mPa deff = 223
cc_top = 40 mm fyt = 276 mPa
cc_bot = 40 mm β = 0.85
cc_side = 40 mm E = 200000
dagg = 19 mm εty = 0.0014
Reinforcements
FLEXURAL REINFORCEMENTS
END MID
TOP n Bar Min Clr Act Clr Remarks TOP n Bar Min Clr Act Clr Remarks
1st layer 3 D12 50.00 55.00 OK 1st layer 2 D12 50.00 122.00 OK
Clear Spc. - - 25.00 25.00 OK Clear Spc. - - 25.00 110.00 OK
2nd layer 2 D12 50.00 122.00 OK 2nd layer 0 D16 50.00 0.00 OK

BOT n Bar Min Clr Act Clr Remarks BOT n Bar Min Clr Act Clr Remarks
2nd layer 0 D16 50.00 0.00 OK 2nd layer 0 D12 50.00 0.00 OK
Clear Spc. - - 25.00 0.00 OK Clear Spc. - - 25.00 30.00 OK
1st layer 2 D12 50.00 122.00 OK 1st layer 3 D12 50.00 55.00 OK
Side bar 0 D16 50.00 0.00 OK Side bar 0 D16 50.00 0.00 OK
SHEAR REINFORCEMENTS
Bar Size D12
Y-direction 3
LEGS

Z-direction 3
Flexure Design
END MID
MAJOR AXIS
TOP BOT TOP BOT
Muz- - kN-m 0 kN-m - kN-m 9.367 kN-m
Muz+ 27.956 kN-m - kN-m 0 kN-m - kN-m
a=Asfy/0.85fc'b 34.945 mm 13.978 mm 13.978 mm 20.967 mm
c=a/β 41.111 mm 16.444 mm 16.444 mm 24.667 mm
fs 2351.019 mPa 7317.546 mPa 7317.546 mPa 4678.364 mPa
εt=fs/Es 0.012 0.037 0.037 0.023
Classification Tens. Controlled OK Tens. Controlled OK Tens. Controlled OK Tens. Controlled OK
φ 0.9 0.9 0.9 0.9
d 202.2 mm 217 mm 217 mm 217 mm
2
Rn=Mu/φbd 3.03900 0.00000 0.00000 0.88409
ρcalc 0.01215 0.00000 0.00000 0.00329
ρmin 0.00507 0.00507 0.00507 0.00507
ρmax 0.02356 - - 0.02356
ρreq 0.01215 - - 0.00507
ρprov 0.01118 OK - - - - 0.00625 OK
ρreq/ρprov 109% - - 81%
φMn 28.806 kN-m - - 19.323
Mu/φMn 97% - - 48%
END MID
MINOR AXIS
LEFT RIGHT LEFT RIGHT

Muy- - kN-m 0.796 kN-m - kN-m 0.796 kN-m


Muy+ 0.598 kN-m - kN-m 0.598 kN-m - kN-m
a=Asfy/0.85fc'b 12.707 mm 12.707 mm 12.707 mm 12.707 mm
c=a/β 14.950 mm 14.950 mm 14.950 mm 14.950 mm
fs 7105.925 mPa 7105.925 mPa 7105.925 mPa 7105.925 mPa
εt=fs/Es 0.036 0.036 0.036 0.036
Classification Tens. Controlled OK Tens. Controlled OK Tens. Controlled OK Tens. Controlled OK
φ 0.9 0.9 0.9 0.9
d 192 mm 192 mm 192 mm 192 mm
Rn=Mu/φhd2 0.06554 0.08724 0.06554 0.08724
ρreq 0.00024 0.00032 0.00024 0.00032
ρmin 0.00507 0.00507 0.00507 0.00507
ρmax 0.02356 0.02356 0.02356 0.02356
ρreq 0.00507 0.00507 0.00507 0.00507
ρprov 0.00428 NG 0.00428 NG 0.00428 NG 0.00428 NG
ρreq/ρprov 6% 7% 6% 7%
φMn 10.527 kN-m 10.527 10.527 10.527
Mu/φMn 6% 8% 6% 8%
Shear Check (Vc=0 as per Special Moment Requirement)
END MID

Y-DIR Z-DIR Y-DIR Z-DIR

Vuy 19.26 kN . kN 19.26 kN kN


Vuz 0.388 0.388
d 202.2 mm 192 mm 217 mm 192 mm
Vc 3.938 kN 41.133 kN 0.000 kN 41.133 kN
φ 0.75 0.75 0.75 0.75
Vu≤φ(Vc+0.67√fc'bd) Section OK Section OK Section OK Section OK
φVc 2.954 kN 30.84989958 kN 0 kN 30.84989958 kN
Vu>φVc Stirrups Needed - Stirrups Needed -
Vu<φVc - Stir. not Needed - Stir. not Needed
0.5φVc<Vu<φVc - - - -
Vs 21.74196358 kN 0 kN 25.68 kN 0 kN
Avprov 339.000 mm2 339.000 mm2 339.000 mm2 339.000 mm2
Avmin 32.052 mm2 33.478 mm2 17.199 mm2 33.478 mm2
scalc 870.1440757 mm Check smax mm 790.6303738 mm Check smax mm
smax 101.1 mm 96 mm 54.25 mm 96 mm
sprov 100 mm 100 mm 100 mm 100 mm
Vsmin 17.693 kN 18.480 kN 18.988 kN 18.480 kN
Vsprov 189.186 kN 179.643 kN 203.034 kN 179.643 kN
Vsreq/Vsprov 11% 10% 13% 10%

Special Moment Frame Requirements


Member part of the special moment frame system? = Yes (If no, ignore below)

Dimensions
1) ln >= 4d = 18.2 d OK
2) bw = min(0.3h, 250) = 250 mm OK

Longitundinal Reinforcements
1) pmax = 0.025 = 0.01118 (pprov) OK

Transverse Reinforcements
1) lo = 550 mm
2) s @ lo = 7 ties @ 54.3 mm Use 75
3) s @ rest = rest @ 109 mm

You might also like