DIGITAL SYSTEM indicates when the fluid is too hot. cold. The control logic produces a
APPLICATION The control logic turns on a heating HIGH to turn on a heating element
In this digital system application, element if the temperature sensor when a too-cold condition is
the digital control logic for indicate the fluid is too cold. The indicated; otherwise, the heating
controlling the fluid in a storage control logic keeps the outlet valve element is turned off. When a too-
tank is developed. The purpose of open as long as the low-level sensor hot condition in indicated, an alarm
the logic is to maintain an is immersed and the fluid is at a is activated.
appropiate leve lof fluid by proper temperature. When the fluid When the low-level sensor
level drops below the low-level produces a HIGH output
controlling the inlet and outlet
sensor, the contro logic closes the (indicating that it is immersed) and
valves. Also, the logic must control
oulet valve. when the outputs of both
the temperature of the fluid within temperature sensors are LOW
a certain range and issue an alarm if Operational Requirements (indicating a correct temperature),
any of the level or temperatura The maximum and minimum fluid the control logic opens the outlet
sensors fail. levels are determined by the valve. If the low-level sensor
positions of the level sensor in the output goes LOW or if either
Basic System Operation tank. The output of the each sensor temperature sensor outputs go
The outputs of the system control is HIGH when is immersed in the LOW, the control logic closes the
logic the fluid input, fluid output fluid and is LOW when not outlet valve.
and fluid temperature. The control immersed. When the high-level If the control detects a
logic operates an inlet valve that sensor output is LOW, the control failure in any of the sensors or a
allows fluid to Flow into the tank logic produces a HIGH and the inlet too-hot condition, an alarm is
until high-level sensor is activated valve opens. When the high-level activated. A level-sensor failure is
by being immersed in fluid. When sensor output is HIGH, the control indicated when the high-level is
the high-level sensor is immersed logic produces a LOW and the inlet activated and the low-level sensor
(activated), the control logic closes valve closes. is not active. A temperature-sensor
the inlet valve. The fluid in the tank The fluid must be within a failure is indicated when both are
must be maintained within a specified temperature range before active at the same time. The figure
specified temperatura range as the outlet valve is opened. One shows the tank control system.
determined by two temperature sensor produces a HIGH when the The system inputs and outputs are
sensor. One temperature sensor temperature is too hot and the other summarized in table.
temperature sensor produces a
HIGH when the temperature is too

Fluid storage tank with level and temperature sensors and control
UNIVERSIDAD DEL VALLE – SEDE ZARZAL
FACULTAD DE INGENIERÍA
ESCUELA DE INGENIERÍA ELÉCTRICA Y ELECTRÓNICA
Programa Académico de Ingeniería Electrónica
Diseño Lógico Combinacional – Problema
Periodo académico: 2023-1

Tank control logic inputs and outputs