You are on page 1of 5

Name of Project: hhghh General Notes:

Job No.: hhghh gkg


Client: yyy uyuu
Designed by: uuu hgh
Date: tyyuy
Sheet: 2 Of 2
Jerv Works Const. Ref: Reinforced Concrete Design, pg.416 by: Besavilla
*Input data in green cells

Footing, square

footing no. ghh

specification
fc' 20 MPa
fy 400 MPa
wt. of concrete 23.5 kN/m3
earth unit weight 15.7 kN/m3
q, allowable soil pressure 170 kPa

service load
service Dead load 900 kN
service Live load 1600 kN

column
h 480 mm
b 480 mm

footing OK
assume L 4.2 m2 > = 4.2 OK - soil pressure
assume footing h (min. .20m) 0.8 m. OK - footing depth but may lessen by 5.68%
concrete cover 70 mm

overburden 0.6 m

R-bars to use
Phils. Standard Reinforcing Bars

r-bar
footing reinforcement
25mm

r-bar no.
column dowels
25mm 4 min. 4

Results:
OK - soil pressure
OK - 2-way shear
OK - beam shear
OK - ld of reinforcement
OK - bearing load of column to footing
OK - no. of column dowels
use ld min 400 mm into both column and footing
480 mm

4.2 m 480 mm

15 - 25mm e.w.

0.6 m. overburden

15 - 25mm e.w.

0.8 m

4.2 m

solution

wt. of assume footing 331.632 kN


wt. of overburden 163.9984 kN
total load = wt. of footing +overburden+ column load 2995.63 kN
required footing area = total load / q 17.62136 m2
required footing L = 4.2 m
actual footing L 4.2 m
actual footing area 17.64 m2
Pu = 1.4(DL+overburden) + 1.7LL 4209.598 kN
qu, actual upward soil pressure = Pu/actual foot. area 238.6393 kPa

qa ,allowable value of soil pressure = q* Pu /(DL + LL) 286.2527 kPa >>== 238.6393
OK - soil pressure

check d by punching shear


actual d = 692.5 mm
min c = 480 mm

d/2 c d/2
L

actual punching shear, vn = Vu/Фbod


actual Vu =qu* [L2 - (c+d)2] 3881.527 kN
actual shear vc = Vu / Фbod 1406.019 kPa

allowable punching shear


βc = long side of column / short side of column 1
allowable punching shear, vc = (1+2/βc)√fc'/6 2236.068 kPa
allowable punching shear = √fc'/3 1490.712 kPa
use min. vc = 1490.712 kPa >> == 1406.019
OK - 2-way shear
OK - footing depth but may lessen by
% 5.68

check for beam shear


actual beam shear
r = L/2-c/2-d 1.1675 m
Vu = qu*L*r 1170.168 kN
vn = Vu/θLd 473.3258 kPa

allowable beam shear


va = 1/6√fc' 745.356 kPa >>== 473.3258
OK - beam shear
d 36.5
r c/2

Bending moment

L
x=( L-c)/2 1.86 m
actual bending moment Mu = qu*L*x2/2 1733.753 kN-m
Mn = Mu/.90 1926.392 kN-m
m = fy/.85fc' 23.52941
Rn = Mn/Ld2 956.4359 kPa
ρ = 1/m(1-√1-2mfRn/fy) 0.002462
As = ρ (actual L*d) 7161.964 mm2
no. of bars 15 ea.

check ld
required ld = .02Ab*fy/√fc' 879.9375 mm
or ld = .06dbfy 600 mm
required ld = 879.9375 mm

actual ld = x - concrete cover 1790 mm >>== 879.9375


OK - ld of reinforcement

check bearing stress of footing


allowable = θ*.85fc'A1√(A2/A1) ACI Code
A1 area column = 0.2304 m2
A2 area of square footing at center strip 17.64 m2
√(A2/A1) = 8.75
or max √(A2/A1) = 2
required √(A2/A1) 2
θ= 0.7
allowable = θ*.85fc'A1√(A2/A1) ACI Code 5483.52 kN
actual bearing load = 1.4DL + 1.7LL 3980 kN <<== 5483.52
OK - bearing load of column to footing
required min area of dowels = .005*area column 1152 mm2
actual area of dowels 4 - 25mm 1967.6 mm2 >>== 1152
OK - no. of column dowels

check development length of dowels (in compression)


min. Ld = .04db*fy 400 mm
or min = 200 (ACI 318-83 Section 12-3-1) 200 mm
Ld = db/4(fy/√fc') 559.017 mm
required Ld = Ld(As required/ As actual) 327.296 mm
hence, required min Ld = 400 mm
use ld min 400 mm into both column and footing

Phils. Standard Reinforcing Bars Phils. Standard Reinforcing Bars


r-bar area dia. r-bar area dia.
6mm 28.27 6 6mm 28.27 6
10mm 78.54 10 10mm 78.54 10
12mm 113.10 12 12mm 113.10 12
16mm 201.1 16 16mm 201.1 16
20mm 314.2 20 20mm 314.2 20
25mm 491.90 25 25mm 491.90 25
28mm 615.75 28 28mm 615.75 28
32mm 804.25 32 32mm 804.25 32
491.90 25 491.90 25

ASTM Standard Reinforcing Bars


Phils. Standard Reinforcing Bars