You are on page 1of 1

TABLE I-A : LAP LENGTHS TABLE I-B : LAP LENGTHS

FOR BARS IN TENSION FOR BARS IN TENSION


GENERAL NOTES
1. READ ALL DRAWINGS IN CONJUNCTION WITH ARCHITECTURAL, CIVIL, MECHANICAL, ELECTRICAL & ANY OTHER RELEVANT DRAWINGS.
2. NOTES , GIVEN IN THE DRAWING ARE APPLICABLE TO ALL DRAWINGS UNLESS MENTIONED OTHER WISE, NOTES WRITTEN ON A DRAWING, SHALL BE fc' = 3000 psi fy = 60000 psi fc' = 3000 psi fy = 40000 psi
APPLICABLE TO THAT PARTICULAR DRAWING ONLY UNLESS OTHERWISE CROSS-REFERED.
3. ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE SPECIFICATION OF THE CONTRACT DOCUMENTS, IN ABSENCE OF ANY SPECIFICATION , LOCATION
LOCATION LAP LENGTH LAP LENGTH
ALL MATERIAL AND WORKMANSHIP SHALL CONFORM TO RELEVANT ACI CODES AND SHALL BE SUBJECTED TO APPROVAL OF THE ENGINEER.
4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFETY OF THE STRUCTURE DURING CONSTRUCTION, HE SHALL ALSO VERIFY ALL DIMENSIONS
AND LEVELS BEFORE EXECUTION OF WORK, ANY DISCREPANCY , ERROR OR OMISSION , IF FOUND, SHALL BE BROUGHT TO THE NOTICE OF THE #6 & SMALLER #7 & LARGER #6 & SMALLER #7 & LARGER
ENGINEER FOR CORRECTION AND APPROVAL.
5. ALL LEVELS AND DIMENSIONS ARE IN FEET & INCHES UNLESS OTHERWISE NOTED. BOTTOM BARS 58db 72db BOTTOM BARS 42db 54db
6. FIGURED DIMENSIONS ARE TO BE FOLLOWED.
DESIGN LOADS TOP BARS * 74db 93db TOP BARS * 48db 64db
1. STRUCTURAL DESIGN IS BASED ON THE AMERICAN CONCRETE INSTITUTE's BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE (ACI
318-14). LOADING IS IN ACCORDANCE TO ASCE 7-16 (SEISMIC LOADS FOR ZONE- 2A) COLUMNS/WALLS COLUMNS/WALLS
58db 72db 42db 54db
REINFORCED CONCRETE / PLAIN CONCRETE WORKS VERTICAL BARS VERTICAL BARS
1- CONCRETE ALL ELEMENTS WILL BE OF 3000 PSI CLYNDRICAL STRENGTH AT 28 DAYS.
2- BLINDING PLAIN CONCRETE SHALL BE OF 1500 PSI CYLINDRICAL STRENGTH AT 28 DAYS. TABLE II: STANDARD HOOKS TO MAIN BARS
REINFORCING STEEL:-
1- REINFORCEMENT FOR SLABS TIES & STIRUPS SHALL BE OF DEFORMED BARS GRADE 40 WITH A MINIMUM YIELD STRENGTH OF 40,000 psi CONFORMING INTERNAL 180° HOOK 90° HOOK
BAR BEND
TO ASTM A 615. SIZE DIAMETER D
2- ALL OTHER REINFORCEMENT SHALL BE OF DEFORMED BARS GRADE 60 WITH A MINIMUM YIELD STRENGTH OF 60,000 psi CONFORMING TO ASTM A 615. (IN.) A J A
3- PROVIDE BAR SUPPORTS OR SPACERS TO GIVE THE FOLLOWING CONCRETE COVER TO ALL REINFORCEMENT UNLESS NOTED OTHERWISE ON (IN.) (IN.) (IN.)
DRAWINGS. (COVER IS THE CLEAR DISTANCE FROM THE CONCRETE SURFACE TO THE NEAREST EDGE OFANY REINFORCEMENT)
#3 2¼" 5" 3" 6" OPENING

(MAX.)
2'-0"
#4 3" 6" 4" 8"

#5 3 34" 7" 5" 10"


ELEMENT TOP BOTTOM SIDES
- #6 4½" 8" 6" 1'-0"

(TYP.)
SLABS 3/4" 3/4" 2'-0"

2-6"
(MAX.)
BEAMS 1½" 1½" 1½"
#7 5¼" 10" 7" 1'-2"
COLUMNS - - 1½"
WALLS - - 1½" 6"
#8 11" 8" 1'-4"
ADD 1/2 THE NUMBER OF BARS
RETAINING WALLS - - 2" ABUTTED BY OPENING ON EACH
SIDE @3" c/c.
FOOTINGS/RAFT 2" 2" 2" #9 9½" 1'-3" 11 34" 1'-7"
TYPICAL DETAIL AT SLAB OPENING
#10 10 34" 1'-5" 1'-1¼" 1'-10" (UNLESS NOTED OTHERWISE ON PLAN)
4.USE # 3 BINDING BARS AT 12" C/C FOR TOP REBARS.
5-WHERE NOT INDICATED POSITIVE (+) REINFORCEMENT TO BE CURTAILED AT L/8 OF CLEAR SPAN FROM THE EDGE OF THE 2#4 EXTRA BARS
SUPPORTING BEAM NEGATIVE (-) REINFORCEMENT TO EXTEND 0.33L (0.33xLARGER OF THE CLEAR SPANS) ON EITHER SIDES OF *db IS NORMAL DIAMETER OF THE REINFORCING BAR IN INCHES. TOP RFT
#4 EXTRA BARS
THE SUPPORTING BEAM TO BE MEASURED FROM EDGE OF CONTINOUS BEAM AND 0.25L FOR EDGE BEAM. DETAILING DIMENSION A DETAILING DIMENSION
6-BARS SHOWN STAGGERED ON PLAN SHALL BE PLACED ALTERNATELY.
7-BARS SHOULD BE EVENLY DISTRIBUTED OVER THE EXTENT INDICATED, UNLESS NOTED OTHERWISE ON PLAN. DISTRIBUTION db db
REINFORCEMENT AT RIGHT ANGLE TO MAIN REINFORCEMENT SHALL BE AS SHOWN BELOW, THE MAIN REINFORCEMENT SHALL
NOT BE LESS THAN DISTRIBUTION REINFORCEMENT. J D A EXTRA STIRRUPS OPENING EXTRA STIRRUPS
D STIRRUPS STIRRUPS

SLAB DISTRIBUTION 4db 12 db


THICKNESS REINFORCEMENT
2.5" MIN.
5" # 3@10"c/c WEB RFT OPENING NOT MORE THAN 6" BOTTOM RFT
180° HOOK 90° HOOK 2#4 EXTRA BARS
6" # 3@9"c/c
7" # 3@8"c/c TABLE III: STANDARD HOOKS TO TYPICAL DETAIL AT BEAM OPENING
8" # 3@7"c/c STIRRUPS AND TIES
10" # 4@10"c/c INTERNAL 12db for #6,#7,#8 6
BAR BEND 90° HOOK 135° HOOK
6db for #3,#4,#5
12" # 4@8"c/c 1
SIZE DIAMETER D A
14" # 4@7"c/c (IN.) A A H (APPROX.)
H
D D D

DIMENSION

DIMENSION
DETAILING

DETAILING
7- FOR EVERY 12 FEET,1/2" PRE CAMBER SHALL BE PROVIDED IN CENTER OF FORMWORK FOR SLAB #3 1½" 4" 4¼" 3" A
& BEAMS 6db
3"Min.
db
8-WALLS NOT SHOWN IN BEAMS LAYOUT PLAN / SLAB REINFORCEMENT PLAN ARE NON LOAD BEARING WALLS, #4 2" 4½" 4½" 3" D D
AND TO BE LEFT 18" BELOW FROM SOFFIT OF BEAM / SLAB AND WILL BE COMPLETED AFTER REMOVAL OF SHUTTERING.
TYPICAL COLUMN/WALL
FOUNDATION:- #5 6" 5½" 3 34"
2½" VERTICAL CRANK DETAIL
1- THE FOUNDATIONS HAS BEEN DESIGNED FOR 0.75 TSF SAFE BEARING CAPACITY OF SOIL. 90° HOOK 135° HOOK
2- THE BEARING CAPACITY TO BE CHECKED AT SITE BEFORE EXECUTION AND IN CASE OF
ANY VARIATION, THIS OFFICE SHOULD BE IMMEDIATELY INFORMED FOR REDESIGNING OF
FOUNDATION. CONCRETE CONSTRUCTION
1. ALL STRUCTURAL SURFACES, AGAINST WHICH EARTH IS TO BE FILLED, SHALL BE COATED WITH TWO
COATS OF HOT BITUMEN 10/20 GRADE AT THE RATE OF 0.4 Lbs/Sft/Coat OVER SURFACES AND 5%
PADLO TO BE ADDED IN 3/4" PCC PLASTER.
FOR CONSTRUCTION
SULMAN RUMANZA GOLF COURSE
A3 DHA MULTAN (MASJID)

SHANZAY
DHA MULTAN May 2019
* 05-05-2021 FOR CONSTRUCTION YAWAR SHANZAY KAYANI KAYANI GENERAL NOTES
YAWAR S-01 *