You are on page 1of 2

N65 & N65 NEO Approved by

Yoann MURE
Engineering Update

Engineering Update Number : NOMAD 65 NEO 006


Subsystem: Shaker with VE464
Date: 19/02/2017

Mandatory Specific Information Requires Customer


Acknowledgement Of Receipt

Purpose
This is procedure to help you to troubleshoot QC issue (distortion, phase, force, noise) or simply to make
preventive maitenance on your vibrator. If you provide to sercel information requested here below, we will
assist you to solve it or improve your vibrator.

Vibrator parameters

For hydraulic & nitrogen pressure, please check value with external gauges.

HYDRAULIC PRESSURE Value INSTALLATION RESULT on VLI Value


Vibration high pressure Mass offset
Vibration low pressure Valve offset
Hold down pressure Torque motor offset
Servovalve reducing valve pressure IDENTIFICATION RESULT on VLI
NITROGEN PRESSURE Servo gain
HP 5 Ga accumulator pressure Servo freq
LP 5 Ga accumulator pressure Servo damp
HP mass accumulator pressure Oil compressibility
LP mass accumulator pressure Oil viscosity
PNEUMATIC PRESSURE Oil leakage
Isolation air bag pressure Spool gain
Compensation air bag pressure

Recorder data :

Pick up statistic of production recorded by DPG. This extension file is *.vaps for APS verbose file. This
VAPS file is located in LOG window.

Copy *.VAPS files for last 5 production days.

NOMAD 65 NEO - 0006 1/2


For further details, please contact: customersupport.vib@sercel.com
Local tests :

Set up following parameters on DSD with


VLI in order to record all signals.

In tablet pc, go to following folder and


delete all files.

Make local tests :


 Test 1 : sweep when hydraulic oil is cold (temperature < 30°C).
 Test 2 : sweep when hydraulic oil is hot (temperature > 45°C).
 Test 3 : sweep where vibrator has bad QC.
 Test 4 : take GOOD vibrator, sweep at the same place as test 3. It will be used as reference.

Copy on USB all data which are recorded in


folder previously cleaned:

Last step :

Make zip folder with all previous information and send it to Sercel by email at :

CustomerSupport.Vib@sercel.com
Feel free to report us all tests done by yourself (part changed, observation).

NOMAD 65 NEO - 0006 2/2


For further details, please contact: customersupport.vib@sercel.com