REINFORCEMENT
DIMENSIONS
BOTTOM BARS TOP BARS
FOOTING REMARKS
MKD L B d D DF "X" DIRECTION "Z" DIRECTION "X" DIRECTION "Z" DIRECTION
F1 2200 2200 300 1000 1500 10 MM # @ 150 C/C 10 MM # @ 150 C/C - - 1. SBC OF SOIL IS AS
MENTIONED IN GENERAL
NOTES
F2 2100 2100 350 1000 1500 10 MM # @ 175 C/C 10 MM # @ 175 C/C - -
F3 2800 2800 400 1000 1500 10 MM # @ 125 C/C 10 MM # @ 125 C/C - - 2. FOR DIMENSION REF DRG
NO -CELZ/TD/ST-3002
SHEET NO-17/17
F4 2100 2100 300 1000 1500 10 MM # @ 150 C/C 10 MM # @ 150 C/C - -
F5 2200 2200 300 1000 1500 10 MM # @ 175 C/C 10 MM # @ 175 C/C - -
F6 1900 1900 300 1000 1500 10 MM # @ 200 C/C 10 MM # @ 200 C/C - -
F7 2500 2500 350 1000 1500 10 MM # @ 150 C/C 10 MM # @ 150 C/C - -
L
J K F3
F1 F2 M F1
F3
F4 F4 F5
PROVN OF FIRE STN TO INCL GARAGE FOR TFF AND LIVING ACCN FOR
FIRE CREW WITH ALLIED INFRA INSIDE AREA OF 41 FAD