You are on page 1of 1

POSTS TO BE FIXED WITH

FULL FACE OF CHANNEL


NOTES: SECTION FACING DIRECTION
ADDITIONAL GUARD FENCE
THE OF ADJACENT TRAFFIC
1. BRIDGE ANCHORAGE DEPENDS LENGTH AS REQUIRED BY
ON TYPE OF BRIDGE BARRIER USED. FOR EARTHWORKS. OR CLEAR REFER NOTE 1
DETAILS REFER SD 4081 AND SD 4082. ZONE REQUIREMENTS
REFER TO SD 3501
LOCAL
2. VERGE WIDENING MAY BE
REQUIRED AT PITS AND BREAKAWAY 40

D
1200
CABLE TERMINALS (BCTA's). METRE
RADI
US
EDGE OF SHOULDER
A3.
REVERSED SECTION OF CURVED GUARD
TP
FENCE WITHOUT A STRAIGHT PROVIDES
600mm OFFSET. EACH ADDITIONAL 5m STANDARD SPLAY (BCTA)

E
LENGTH OF STRAIGHT BETWEEN CURVED REFER SD 3571, SD 3541 10000
SECTIONS ADDS 625mm TO THE OFFSET.
DIRECTION OF TRAFFIC
4. BACKING RAIL, 300 LONG, WITH GUARD FULL SHOULDER ON STRUCTURE
RAIL PROFILE , SHALL BE PROVIDED AT
ALL INTERMEDIATE POSTS.

D
POSTS TO BE FIXED WITH
FULL FACE OF CHANNEL

E
SECTION FACING DIRECTION
OF ADJACENT TRAFFIC
40
ME REFER NOTE 1
TR
E
RAD

1200
I
US

20 1
S
7/ 1
EDGE OF SHOULDER

-0 63
TP 40 METR
STANDARD SPLAY (BCTA) E RAD

20
I
US
SHOULDER VARIES TP
REFER SD 3571, SD 3541
TP

R
D
EDGE OF TRAFFIC LANE

DIRECTION OF TRAFFIC

G
10000

& R
E
30m LONG GUARD FENCE NARROW SHOULDER ON APPROACH

E
E
(GUARD FENCE NOT WARRANTED ON APPROACH CONDITIONS)

S
M EF

S
ADDITIONAL GUARD FENCE POSTS TO BE FIXED WITH
FULL FACE OF CHANNEL
P LENGTH AS REQUIRED
BY EARTHWORKS SECTION FACING DIRECTION

D
R
OF ADJACENT TRAFFIC
ADDITIONAL GUARD FENCE

-R
REFN WHERE WARRANTED
OTE3 REFER NOTE 1
TP 40 REFER SD 3502
1200

METRE
U
RADI
US
EDGE OF SHOULDER

TP TP 40 METRE RADI
US TP
STANDARD SPLAY (BCTA)
40 METR
126 E RADI
US
REFER SD 3571, SD 3541 1000 TP
TP
SHOULDER VARIES (REF NOTE 3) EDGE OF TRAFFIC LANE
S

NARROW SHOULDER ON STRUCTURE


DIRECTION OF TRAFFIC
(GUARD FENCE WARRANTED ON APPROACHES) 10000

DESIGNED
E GENERAL NOTES
1. GUARD FENCE - BRIDGE ANCHORAGE SD 4081 AND SD 4082. PRINCIPAL ROAD STANDARD DRAWING
D J.K. 1/7/05 REFERENCE TO SD 3571 & 3541 ADDED & TITLE AMENDED 2. BREAKAWAY CABLE TERMINALS SD 3541 TO SD 3561. DESIGN ENGINEER

C J.B. 1/7/01
POST ORIENTATION NOTE AND DIRECTION OF TRAFFIC ADDED
BREAK ADDED IN GUARD FENCE LOWER DWG.
3. GUARD FENCE - LOCATION SD 3501 AND SD 3502
SD 3511
APPROVED GUARD FENCE
4. GUARD FENCE (LINE A)
B J.C. OCT'99 REDEFINED GUARD FENCE NOT WARRANTED 5. GUARD FENCE (LINE B) SD 3521
ENGINEERING & TECHNOLOGY CONSULTANTS
LAYOUTS FOR BRIDGE APPROACHES
6. ALL DIMENSIONS ARE IN MILLIMETRES UNLESS 24. 2. 94
A R.G. FEB 94 BRIDGE ANCHORAGE, DASHED SECTION OF GUARD FENCE AND GENERALNOTES 1, 3 AND 6. SHOWN OTHERWISE. CATALOG: PRED COMPUTER FILE SCALE HOR NOT TO SCALE FILE N0. CONTRACT NO. SHEET NO. DRAWING NO. ISSUE
OF
ISSUE APP'D DATE AMENDMENT PROJECT: sddgnnew sd-4071d.dgn METRES VER SD 4071 D

You might also like