You are on page 1of 1

NWR BKN DIVISIONAL PLAN NO. - Sr.

DEN/ /2023
MINOR MODIFICATION IN RDSO DRG. NO. M-00006/R-2 FOR PROPOSED WASHING
LINE AT HANUMANGARH STN.
NOTES:-
C.L. OF PROP. WASHING 1. ALL DIMENSIONS ARE IN MILLIMETERS EXCEPT OTHERWISE WHERE STATED.
LINE/PIT 2. THIS SKETCH IS PREPARED BASED ON RDSO DRG. NO: M-00006/R2 AND
C.L. OF EXISTING LETTERNO. 964803/2022/0/0 DY CME/PLG/HQ/NWR & SWR/CN/BNC/ST/217-07.
MAIN LINE 3. MINOR MODIFICATION HAS BEEN MADE IN WASHING LINE PIT DEPTH (ACCORDING TO VANDE BHARAT TRAIN)
8800 AS PER DIRECTOR (MECHANICAL) CAMTECH/GAWALIOR'S LETTER NO:IRCAMTECH/M/GWL/TRAIN
SET DATED: 31.05.2022
3515 3515 4. ALL STRUCTURAL DETAILS SHALL BE AS PER RDSO DRG. NO: M-00006/R2. EXCEPT MODIFICATION
MADE AS ABOVE.
5. LIFTING PADS ARE NOT BEING PROVIDED AS THE WASHING LINE HAS TO BE USED FOR LHB, ICF AS WELL
1800 1800 AS VANDE BHARAT TYPE OF RAKES. HENCE STEEL BETWEEN MAIN COLUMN SECTION HAS BEEN REDUCED.
320 1480 1480 320 6. IN RAFT DUE TO INCREASE IN FOUNDATION DEPTH FROM 1810MM TO 2400MM BEARING CAPACITY OF SOIL
TOP OF CAT
120 120 WALK LVL. INCREASE. HENCE REINFORCEMENT SPACING IN RAFT HAS BEEN INCREASE FROM 150MM C/C TO 200MM C/C. IN
200 200
420 TOP .

1040
8MM DIA RING 1746 2642
@130MM C/C 320
1676 RAIL. LVL.
210 TOP OF PIT
RCC BEAM

1075
@100C/C
1:20

1800
8MM DIA STIRRUPS 313 520 LINK 10MM DIA BAR @ 150C/C
@150MM C/C COLUMN 450X520MM MAIN COLUMN BAR

325
10MM DIA STIRRUPS 600 10# 20MM DIA
CAT WALK COLUMN @200MM C/C EARHT
EARHT 2675

400
320X320MM 600MM C/C FILLING
FILLING 590 10MM DIA STIRRUPS
@150MM C/C

450
450 450 450 450 RAFT FOUNDATION 100 833 (520+313)
2 # - 16MM DIA
PCC 1:3:6 150 LINK BAR 10MM DIA
8730
2642

CROSS SECTION OF WASHING LINE 2# 16MM DIA BAR


VERTICAL BAR 10 DIA DIST. BAR @ 600 C/C
(DRG NO.-1) 16 MMDIA @ 200C/C

CROSS SECTION PLAN OF MAIN COLUMN


CAT WALK SLAB (DRG NO.-2)
2500 2500 320
TOP OF CAT

370
WALK LVL. 200
RAIL. LVL.
670
470

10mm DIA BAR


TOP OF R/WALL LVL. @ 150 C/C

1:12
370

RAIL. LVL. 8mm DIA BAR

1800
@ 200C/C
RCC RETAINING WALL RCC RETAINING WALL CAT WALK COLUMN
2840

320x320 MM (WALL RCC)


3290

2170
1800

590
500

450
RAFT FND.
300mm.
PCC 1:3:6 150
450

RAFT FOUNDATION X-SECT. OF R/WALL


150
PCC 1:3:6
(B/W CAT WALK COL.)
SECTIONAL ELEVATION DRG. NO.-3
STRUCTURAL DRG & DESIGN CHECKED & FOUND CORRECT SR. DEN/C/BKN

SSE/W/HMH-I ADEN/HMH-I
JE/W/HMH-I
DEN/N/BKN

You might also like