TOP OF TOOL BROWN BROWN BOTTOM OF TOOL

D2
TP1 BROWN

1N5062
R1 C1
D1 TP1 TP3
1MEG (RN55) 2.2uF MANGANIN TP3 YELLOW TP3 TP23
TP5 1 2 YELLOW
TP15
Q1 1N4960 TP24
TOP
IRFBG30/TO MANGANIN TP12 RED TP37 RED
D2
CMPD400
TP2
YEL TP7
D1 MANGANIN BLACK/SHIEL
1N4744 R*A SHIELDED
YELLOW
TP8
MANGANIN TP4

R30 TP11 ORANGE TP1


SIT RED TP9 8135-PCB7-168-1
R*B MANGANIN 8135-16850P-1
8101-168B0X-N
OVERVOLTAGE PCB MANGANIN SCH. 350S16A8-1
YELLOW TP6 BLACK TP8
TP12
SCH. 011S16AH MANGANIN TP5 TP7

D7

1N5622
D8

IN5622
TOP MANGANIN
TECHNICAL MANUAL MANGANIN

MANGANIN
TP19

TP20

TP21
U1-PIN6

U13-PIN6
DITHERING CIRCUIT JUMPER
.NOT USED IN 8135
APPLICATION

&
MANGANIN
PRESSURE PCB
TP24 * 8138-PCB-168
MANGANIN
8138-16850P
SCH. 380S27A0
TP25 *
MANGANIN 8135-PCB7-168
8135-16850P
SCH. 350S16A8

* USED IN 8138 APPLICATION ONLY

REF. F131059000 763XA


Effective January 14, 2014
(See paragraph 3 for Hold Harmless Terms)

Effective January 14, 2014 Page 1 of 8


Effective January 14, 2014 Page 2 of 8
Effective January 14, 2014 Page 3 of 8
Effective January 14, 2014 Page 4 of 8
Effective January 14, 2014 Page 5 of 8
Effective January 14, 2014 Page 6 of 8
Effective January 14, 2014 Page 7 of 8
et seq
et seq

Effective January 14, 2014 Page 8 of 8


Subject: P117 - Baker Atlas 1-11/16” 350F Perforators 735XB and 763XA Rev. F

FINAL INSPECTION AND TEST


BAKER ATLAS
1-11/16” MODEL # 735XB and 763XA PFC

Date:
Job #: Sales Order #:
Tool P/N: Tool S/N:
Inspector #: Pass/Fail:

VIBRATION TEST

Shake @ 5G’s for 15 min. Z-Axis


Pulse Height at the Top of the Tool
Counting Rate Prior to the Test
Counting Rate in the Middle of the Test
Counting Rate at the End of the Test
Base Line Noise (Cannot exceed 10% of the pulse height)

Source Present:

TEST PROCEDURE

Source Type: BA REVISION LEVEL: ________A2


FMNS: 03-15

Apply 85 ± 0.5 Vdc to Upper Center Contact with Respect to Mass and Measure with a DMM.
Measurement made at the Bottom contact should be made across a 5 K
DMM or with a Simpson 260 without a Load resistor.
Tool Current: mA (40 - 55)
Voltage at the Bottom Contact: Vdc (0.0 volts, measured across a 5 K ohm resistor
from Bottom contact to mass.)
GR Pulse Height at the Top of the Tool: Vp (-7 - -13)
Pulse Width at the Top of the Tool: µsec (32 - 38)
CCL Signal: Vpp.
5 of 6
Subject: P117 - Baker Atlas 1-11/16” 350F Perforators 735XB and 763XA Rev. F

Note: Sources must be more than 25ft. from the tool to measure the background counting rate.

Calibrator Count Rate: cps


Background Count Rate: cps
Differential Count Rate: cps
Differential Count Rate x 60: cpm
(12,000 ± 15% 763XA)
(11,700 ± 15% 735XB)
Minimum Voltage for GR Pulse Output: Vdc
Pulse Height with Minimum Voltage Applied: Vp

Apply -200 VDC to the Top Center Contact with Reference to Mass and Measure:

Tool Current: mA
Voltage at the Bottom Contact: Vdc

Apply operating voltage to the top of the tool and increase until the tool switches.

F- Vdc (185 - 215)


Voltage at the Bottom of the Tool after the Relay Switches: Vdc

Use a Fluke Model 87 Multimeter, or better, set to the Diode Testing Function. Measure from the
Top Contact to the Bottom Contact.

(COM) Top and (V) Bottom: Vdc (1 - 1.4)


(V) Top and (COM) Bottom: (Open)

Use a Simpson 260, or Equiv., Measure Resistance.

(+) Lead on the Top Contact and (-) Lead to Mass: Kohms (20 – 150)
(Allow time for capacitor to charge)
(-) Lead on the Top Contact and (+) Lead to Mass: Megohms
(No less than 20Megohms)

Inspector: Date: