You are on page 1of 8

C-FIX 1.110.0.

0
Database version
2022.7.20.14.22
Date
11/11/2022

fischer fixings LLC

62 Orange Ave
10901 Suffern, NY
Phone: +1 845 504 5098
Fax: +1 845 625 2666
info@fischerfixingsusa.com
www.fischerfixingsusa.com

Design Specifications
Anchor
Anchor system fischer Bolt anchor FAZ II
Anchor Bolt anchor FAZ II 12/20,
zinc plated steel
Calculated anchorage 70 mm
depth

Geometry / Loads / Scale units


mm, tf, tfm

black: Value of design actions (including

partial safety factor for the load)

blue: Sustained Loads has to be Static

respected according ACI.

Not drawn to scale

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 1
C-FIX 1.110.0.0
Database version
2022.7.20.14.22
Date
11/11/2022

Input data

Design method Design method ACI 318-14 Mechanical


Load Combination Design Loads ACI 318-14 Chapter 5.3
Base material Normal weight concrete, 4000 psi, ACI 318
Concrete condition Cracked, dry hole
Reinforcement Tension: Condition A. Shear: Normal or no reinforcement. No
edge reinforcement. With reinforcement against splitting
Drilling method Hammer drilling
Installation type Push-through installation
Annular gap Annular gap not filled
Type of loading Permanent-Transient/Static
Base plate location Base plate flush installed on base material
Base plate geometry 150 mm x 302 mm x 16 mm
Profile type Customized profile

Design actions *⁾
# NSd VSd,x VSd,y MSd,x MSd,y MT,Sd Type of loading
tf tf tf tfm tfm tfm
1 4.70 0.00 0.25 0.00 0.00 0.00 Permanent-Transient/Static
0.00 - - 0.00 0.00 - Sustained Load

*⁾ The required partial safety factors for actions are included

Resulting anchor forces


Tensile action Shear Action Shear Action x Shear Action y
Anchor no. tf tf tf tf
1 1.18 0.06 0.00 0.06
2 1.18 0.06 0.00 0.06
3 1.18 0.06 0.00 0.06
4 1.18 0.06 0.00 0.06

max. concrete compressive strain : 0.00 ‰


max. concrete compressive stress : 0.0 MPa
Resulting tensile actions : 4.70 tf , X/Y position ( 0 / 0 )
Resulting compression actions : 0.00 tf , X/Y position ( 0 / 0 )

Resistance to tension loads


Action Capacity Utilisation βN
Proof tf tf %
Steel failure 1.18 2.83 41.5
Concrete cone failure 2.35 2.39 98.5

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 2
C-FIX 1.110.0.0
Database version
2022.7.20.14.22
Date
11/11/2022

Steel failure Table 17.3.1.1

Values taken from ICC ES Report.

Nsa ϕs ϕ Nsa Nua βN,s


tf tf tf %
3.77 0.75 2.83 1.18 41.5

βN,s
Anchor no. % Group N° Decisive Beta
1 41.5 1 βN,s;1
2 41.5 2 βN,s;2
3 41.5 3 βN,s;3
4 41.5 4 βN,s;4

Concrete cone failure Table 17.3.1.1

Eq.
(17.4.2.1a/1b)

Eq.
(17.4.2.1c)

Eq.
(17.4.2.2a)

Eq. (17.4.2.4)

Eq.
(17.4.2.5a/5b)

Eq. (17.4.2.6)

Ncbg ϕc ϕ Ncbg Nuag βN,cb


tf tf tf %
3.18 0.75 2.39 2.35 98.5

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 3
C-FIX 1.110.0.0
Database version
2022.7.20.14.22
Date
11/11/2022

βN,cb
Anchor no. % Group N° Decisive Beta
1, 2 98.5 1 βN,cb;1
3, 4 98.5 2 βN,cb;2

Resistance to shear loads


Proof Action Capacity Utilisation βV
tf tf %
Steel failure 0.06 2.05 3.0
Concrete pry-out failure 0.12 4.45 2.8

Steel failure Table 17.3.1.1

Values taken from ICC ES Report.

Vsa ϕs ϕGrout ϕ Vsa Vua βV,s


tf tf tf %
3.16 0.65 1 2.05 0.06 3.0

βV,s
Anchor no. % Group N° Decisive Beta
1 3.0 1 βV,s;1
2 3.0 2 βV,s;2
3 3.0 3 βV,s;3
4 3.0 4 βV,s;4

Concrete pry-out failure Table 17.3.1.1

Eq.
(17.5.3.1a/b)

Eq.
(17.4.2.1a/1b)

Eq.
(17.4.2.1c)

Eq.
(17.4.2.2a)

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 4
C-FIX 1.110.0.0
Database version
2022.7.20.14.22
Date
11/11/2022

Eq. (17.4.2.4)

Eq.
(17.4.2.5a/5b)

Eq. (17.4.2.6)

Vcpg ϕc ϕ Vcpg Vuag βV,cp


tf tf tf %
6.36 0.70 4.45 0.12 2.8

βV,cp
Anchor no. % Group N° Decisive Beta
1, 2 2.8 1 βV,cp;1
3, 4 2.8 2 βV,cp;2

Utilization of tension and shear loads

Tension loads Utilisation βN Shear Loads Utilisation βV


% %
Steel failure * 41.5 Steel failure * 3.0
Concrete cone failure 98.5 Concrete pry-out failure 2.8
Sustained load failure

* Most unfavourable anchor

Resistance to combined tensile and shear loads

Proof successful
Eq. (17.6.3)

Information concerning the anchor plate


Base plate details
Plate thickness specified by user without proof t = 16 mm

Profile type Customized profile

Technical Remarks
The transmission of the anchor loads to the supports of the concrete member shall be shown for the ultimate limit state and
the serviceability limit state; for this purpose, the normal verifications shall be carried out under due consideration of the
actions introduced by the anchors. For these verifications the additional provisions given in the current design method shall
be taken into account.
As a pre-condition the anchor plate is assumed to be flat when subjected to the actions. Therefore, the plate must be
sufficiently stiff. The C-Fix anchor plate design is based on a proof of stresses and does not allow a statement about the
The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 5
C-FIX 1.110.0.0
Database version
2022.7.20.14.22
Date
11/11/2022

stiffness of the plate. The proof of the necessary stiffness is not carried out by C-Fix.

The anchors must be installed in accordance with the manufacture's installation instructions. Please check the latest ICC-ES
Evaluation Report

Supplemental reinforcement: Condition A applies where supplementary reinforcement is present except for pullout and pryout
strength.
Condition B applies where supplemental reinforcement is not present and for pull out or pry out strength.

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 6
C-FIX 1.110.0.0
Database version
2022.7.20.14.22
Date
11/11/2022

Installation data
Anchor
Anchor system fischer Bolt anchor FAZ II
Anchor Bolt anchor FAZ II 12/20, Art.-No. 95420
zinc plated steel

Accessories Quattric II 12/110/160 Art.-No. 549932


or alternatively
FHD 12/200/330 Art.-No. 546597
Hammer drilling with or without
suction

Installation details
Thread diameter M 12
Drill hole diameter d0 = 12 mm
Drill hole depth h2 = 90 mm
Calculated anchorage hef = 70 mm
depth
Installation depth hnom = 84 mm
Drilling method Hammer drilling
Drill hole cleaning
Installation type Push-through installation
Annular gap Annular gap not filled
Installation torque Tinst = 0.01 tfm
Socket size 19 mm
Base plate thickness t = 16 mm
Total fixing thickness tfix = 16 mm
Tfix,max tfix, max = 20 mm

Base plate details


Base plate material S 235 (St 37)
Base plate thickness t = 16 mm
Clearance hole in base df=14 mm
plate

Attachment
Profile type Customized profile

Profile dimensions mm
Height 100
Web thickness 3
Flange thickness 3
Load application on X-axis 95

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 7
C-FIX 1.110.0.0
Database version
2022.7.20.14.22
Date
11/11/2022

Anchor coordinates

x y
Anchor no. mm mm
1 -45 130
2 45 130
3 -45 -130
4 45 -130

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 8

You might also like