You are on page 1of 4

Rectangular Beam Deflection A.C.I.

435-R08 b

Single Span One End Continuous Span


Compressive Strength F'c28 300 kg/cm2 Compressive Strength F'c28
Section Width B 100 cm Section Width B
Section Height H 30 cm Section Height H
Bottom Reinforcement As 32.00 cm2 Bottom Reinforcement As
Reinforcement Depth d 25.00 cm Reinforcement Depth d
Top Reinforcement A's 20.00 cm2 Top Reinforcement A's
Reinforcement Depth d' 4.50 cm Reinforcement Depth d'
Span Length 400 cm Span Length
Service Dead Load 5.00 T/m Service Dead Load
Service Live Load 1.00 T/m Service Live Load
Percentage of Sustained LL 25 % Percentage of Sustained LL
K)d Cdts of Supports
K Support Fixity Conditions 1 K)d+l Cdts of Supports
K)sus Cdts of Supports

Moment (dead load) 12.00 T.m Moment (dead load)


Moment (dead+live load) 15.00 T.m Moment (dead+live load)
Moment (sustained load) 15.00 T.m Moment (sustained load)

Initial Deflection ∆i)d 0.75 cm Initial Deflection ∆i)d


Initial Deflection ∆i)d+l (cm) 0.99 cm Initial Deflection ∆i)d+l (cm)
Initial Deflection ∆i)sus (cm) 0.99 cm Initial Deflection ∆i)sus (cm)
Initial Deflection ∆i)l (cm) 0.24 cm Initial Deflection ∆i)l (cm)
Limit ∆i)l - L/180 2.22 cm Limit ∆i)l - L/180
Limit ∆i)l - L/360 1.11 cm Limit ∆i)l - L/360

λ Parameter for 5 years 1.43 λ Parameter for 5 years


Long Term Def ∆Cr+Sh 1.42 cm Long Term Def ∆Cr+Sh
Long Term Def ∆lt 1.66 cm Long Term Def ∆lt
Ratio L/∆ L/ 242 Ratio L/∆
Limit ∆lt - L/480 0.83 cm Limit ∆lt - L/480
Limit ∆lt - L/240 1.67 cm Limit ∆lt - L/240
Input Continuity Parameters
Bottom Reinforcement As
Reinforcement Depth d
Top Reinforcement A's
Reinforcement Depth d'
Input Continous Section Moments
Cont Section Moment Md
Cont Section Moment Md+l
Cont Section Moment Msus
flection A.C.I.435-R08 by Joseph Asfour

nd Continuous Span Both Ends Continuous Span


300 kg/cm2 Compressive Strength F'c28 300 kg/cm2

100 cm Section Width B 100 cm

30 cm Section Height H 30 cm

32.00 cm2 Bottom Reinforcement As 32.00 cm2

25.00 cm Reinforcement Depth d 25.00 cm

20.00 cm2 Top Reinforcement A's 20.00 cm2

4.50 cm Reinforcement Depth d' 4.50 cm

400 cm Span Length 400 cm

5.00 T/m Service Dead Load 5.00 T/m

1.00 T/m Service Live Load 1.00 T/m

25 % Percentage of Sustained LL 25 %

1.0333333 K)d Cdts of Supports 1.0333333

1.0400000 K)d+l Cdts of Supports 1.0400000

1.0600000 K)sus Cdts of Supports 1.0600000

12.00 T.m Moment (dead load) 12.00 T.m

15.00 T.m Moment (dead+live load) 15.00 T.m

15.00 T.m Moment (sustained load) 15.00 T.m

0.74 cm Initial Deflection ∆i)d 0.56 cm

0.98 cm Initial Deflection ∆i)d+l (cm) 0.73 cm

1.00 cm Initial Deflection ∆i)sus (cm) 0.74 cm

0.24 cm Initial Deflection ∆i)l (cm) 0.16 cm

2.22 cm Limit ∆i)l - L/180 2.22 cm

1.11 cm Limit ∆i)l - L/360 1.11 cm

1.43 λ Parameter for 5 years 1.43

1.43 cm Long Term Def ∆Cr+Sh 1.06 cm

1.66 cm Long Term Def ∆lt 1.22 cm

L/ 240 Ratio L/∆ L/ 328

0.83 cm Limit ∆lt - L/480 0.83 cm

1.67 cm Limit ∆lt - L/240 1.67 cm


tinuity Parameters Input Left Continuity Parameters
49.00 cm2 Bottom Reinforcement As 42.00 cm2

25.00 cm Reinforcement Depth d 34.70 cm

32.00 cm2 Top Reinforcement A's 12.00 cm2

4.50 cm Reinforcement Depth d' 4.30 cm

ntinous Section Moments Input Left Continous Section Moments


15.00 T.m Cont Section Moment Md 7.00 T.m

17.00 T.m Cont Section Moment Md+l 12.00 T.m

17.00 T.m Cont Section Moment Msus 10.00 T.m

Input Right Continuity Parameters


Bottom Reinforcement As 42.00 cm2

Reinforcement Depth d 34.70 cm

Top Reinforcement A's 12.00 cm2

Reinforcement Depth d' 4.30 cm

Input Right Continous Section Moments


Cont Section Moment Md 7.00 T.m

Cont Section Moment Md+l 12.00 T.m

Cont Section Moment Msus 10.00 T.m