You are on page 1of 2

Prestressing Record

(Calulation For pressure and Elongation)


Name of Work:

Name of Client:
Name of Contractor:

Type of Cable : CL-II LR Date : 28-Jun-17


Cable
belonging to Girder No. :
Coil No. : X 5301 F
Supplier : Tata Steel Cable No. : 1.00
Theoretical E Length of
195.00 :
Value : kN/mm2 Cable 13.69 m
Actual E Value Test Report
204.80 :
: kN/mm2 Ref.
Theoretical Theoretical A
Elongation at 90.27 mm Value : = ( 1100.00 / 11.00 ) = 100.00
Site :
Jack Efficiency Actual A Value
98.95% : 99.65
:
PSC Girder Theoretical
Detail Jacking Force : 143.28
: GM/E/MB/95820
Jack Ram Area
: 563.72

Design
Elongation : 84.60 mm
Design Length
12.03 m + 0.80 = 12.83 m
of Cable 'L'
=
Actual Cable
12.03 m + 0.25 + 0.25 + 0.58 + 0.58 = 13.69 m
Length at Site =

Design
'x'
Elongation
Theoretical Design =
Actual Cable
elongation at = Length of = 90.27 mm
Length at Site
Site 'x' Cable
84.60 mm 'x'
=
12.83 m 13.69 m

Theoretical Theoretical A Theoretical E


Elongation X X
Modified Actual A Actual E
= = 86.25 mm
elongation 100.00 195.00
90.27 mm X X
99.65 204.8

Min. Elongation = (- 5.00 %) = 81.94 mm Max. Elongation = (+ 5.00 %) = 90.57 mm

Modified Theoretical Jacking Force 143.28 Tons


= = = 144.80 Tons
Jacking Force Jack Efficiency 98.95%

Modified Modified Jacking Force 144.80 Tons


= = = 256.87
Pressure Jack Ram Area 563.72

Min. Pressure = (- 5.00 %) = 244.02 Kg/cm2 Max. Pressure = (+ 5.00 %) = 269.71

Locking Pressure = ( 75.00 %) of Pretensioning = 192.65

Client Representative For Contractor Sign

676401868.xlsx
Prestressing Record
(Calulation For pressure and Elongation)

mm2

mm2

Tons

cm2

Kg/cm2

Kg/cm2

Kg/cm2

676401868.xlsx