ARCHITECTURE

FILE LOCATION:
D:\VITAL ENGINEERING DROPBOX\YASSER GONZALEZ\PROJECTS\2021\21055 250 MERRICK RESIDENTIAL DEVELOPMENT\WORK DRAWINGS\E-1.00 ELECTRICAL SITE PLAN.DWG

PRINTED ON:08.03.2022
P L A N N I N G
ALTERNATE BID NOTES: GENERAL NOTES: I N T E R I O R S
CONTRACTOR TO PROVIDE ALTERNATE BID TO CONNECT EXISTING 1. CONTRACTOR SHALL CONTACT SUNSHINE STATE ONE-CALL AT CERTIFICATIO N No. AA0002451

3-STORY OFFICE BUILDING MAIN ELECTRICAL ROOM TO NEW POWER 1-(800)-432-4770 AT LEAST 48 HOURS PRIOR TO PERFORMING ANY
DIGGING TO VERIFY THE EXACT LOCATION OF EXISTING UTILITIES. A 4533 PONCE DE LEON BLVD.
COMPANY TRANSFORMER VAULT LOCATED IN THE 12-STORY Coral Gables, Florida 33146
MIXED-USE RENTAL DEVELOPMENT: CONTRACTOR'S REPRESENTATIVE MUST BE PRESENT WHEN UTILITY
TEL: (305) 740-5442
COMPANIES LOCATE THEIR FACILITIES.
FAX: (305) 740-5443
1. CONTRACTOR SHALL VISIT THE EXISTING 3-STORY OFFICE BUILDING 2. THE CONTRACTOR IS ADVISED THAT PROPERTIES ADJACENT TO THE E-MAIL: info@beharfont.com
TO VERIFY AND INSPECT EXISTING FIELD CONDITIONS. PROJECT HAVE ELECTRIC, TELEPHONE, GAS, WATER, AND/OR
2. CONTRACTOR SHALL MODIFY ALL EXISTING ELECTRICAL SEWER SERVICE LATERALS WHICH MAY NOT BE SHOWN IN PLANS. © 2019 BEHAR FONT & PARTNERS P.A.

INSTALLATION IN MAIN ELECTRICAL ROOM OF 3-STORY OFFICE THE CONTRACTOR MUST REQUEST THE LOCATION OF THESE THE DESIGN AND DRAWINGS FOR THIS
PROJECT ARE THE PROPERTY OF THIS
BUILDING AS REQUIRED TO IMPLEMENT THE DESIGN INTENT. LATERAL SERVICES FROM THE UTILITY COMPANIES. THE ARCHITECT AND ARE PROTECTED UNDER THE
ADDITIONAL COST OF EXCAVATING, INSTALLING, BACKFILLING, AND COPYRIGHT PROTECTION ACT.

3. ELECTRICAL SCOPE OF WORK ON EXISTING 3-STORY OFFICE COMPACTING AROUND THESE LATERAL SERVICES MUST BE SEAL:
BUILDING SHALL BE SCHEDULED AFTER HOURS AND WEEKENDS TO INCLUDED IN THE BID RELATED ITEM FOR THE WORK BEING DONE.
MINIMIZE POWER INTERRUPTION TO THE EXISTING TENANTS.
3. THE CONTRACTOR IS TO USE CAUTION WHEN WORKING IN OR
4. PROVIDE SIGN IN 3-STORY OFFICE BUILDING MAIN ELECTRICAL AROUND AREAS OF OVERHEAD AND UNDERGROUND UTILITIES.
ROOM STATING THAT ELECTRICAL SERVICES TO THE 3-STORY 4. UNDERGROUND CONDUITS (SCHEDULE 40 PVC) SHALL BE
OFFICE BUILDING ARE CONNECTED TO THE POWER COMPANY PROTECTED AGAINST DAMAGE AS REQUIRED BY N.E.C. ART. 230.32.
TRANSFORMER VAULT IN THE 12-STORY MIXED-USE RENTAL WITH 24" MIN. COVER AND/OR PROVIDE 2" CONCRETE ENCASEMENT
DEVELOPMENT. IN THE EVENT COVER IS LESS THAN 24".
5. KEY NOTE NO.3: CONTRACTOR REMOVE EXISTING POWER COMPANY 5. CONTRACTOR SHALL BACKFILL AND REGRADE, REPAVE AND FILL-IN
PAD MOUNTED. COORDINATE DETAILS WITH POWER COMPANY FIELD SODDING AS REQUIRED FOR ALL TRENCHES AND EXCAVATIONS
REPRESENTATIVE. PROVIDED FOR THE INSTALLATION OF NEW UNDERGROUND JOSE A. RAMIREZ, P.E.
CONDUITS. P.E. 0060224
6. KEY NOTE NO.5: REMOVE EXISTING FEEDERS AND ABANDON
CONSULTANT:
EXISTING CONDUIT IN PLACE. 6. PROVIDE A MINIMUM OF ONE PULL BOX PER 100'-0" OF NEW
UNDERGROUND CONDUIT INSTALLATION.
7. KEY NOTE NO.6: PROVIDE 4-750 MCM (AL) IN EACH OF 6-4"C.
TERMINATE NEW ELECTRICAL SERVICE CONDUCTORS EXISTING 7. CONTRACTOR SHALL REPAIR OR REPLACE THE ALL SEGMENTS OF
3-STORY OFFICE BUILDING MAIN ELECTRICAL ROOM AND REWIRE THE EXISTING CHAIN LINK FENCE AND/OR EXISTING CONCRETE
EXISTING ELECTRICAL SERVICE MAINS DISCONNECT TO NEW POWER SIDEWALK AFFECTED BY THE NEW ELECTRICAL UNDERGROUND
COMPANY TRANSFORMER VAULT. COORDINATE INSTALLATION CONDUITS INSTALLATION AS REQUIRED.
DETAILS WITH POWER COMPANY FIELD REPRESENTATIVE. 8. LOCATION OF ANY ELECTRICAL EQUIPMENT SUCH AS,
8. THE CONTRACT'S BID SHALL INCLUDE ALL LABOR, MATERIALS, WORK TRANSFORMER, JUNCTION BOXES, CONDUITS, AND DISTRIBUTION
SCHEDULE, COORDINATION WITH 3-STORY OFFICE BUILDING PANEL ARE APPROXIMATE ONLY. COORDINATE AND VERIFY
MANAGEMENT AND POWER COMPANY FIELD REPRESENTATIVES LOCATIONS WITH TENANT'S REPRESENTATIVE.
NECESSARY TO IMPLEMENT ALTERNATE BID'S SCOPE OF WORK.

KEY NOTES:

FINISHED GRADE AND/OR 1 APPROXIMATE LOCATION OF NEW FP&L 13'-7"L X 8'-2"W X 9'-0"H
CONCRETE FLOOR SLAB MANHOLE. MANHOLE TO BE PROVIDED AND INSTALLED BY POWER
COMPANY UNDER A SEPARATE PERMIT (SHOWN FOR REFERENCE

42" (MIN. COVER)


NOTE: ONLY). COORDINATE EXACT LOCATION WITH CIVIL DRAWINGS AND
COORDINATE DUCT BANK INSTALLATION DETAILS POWER CO. FIELD SERVICE REPRESENTATIVE IN THE FIELD
WITH FLORIDA POWER AND CO. FIELD
REPRESENTATIVE PRIOR TO COMMENCEMENT
BIRD ROAD OF WORK. 2 APPROXIMATE UNDERGROUND ROUTING OF 8-5"C AND 2-2"C ENCASED
IN CONCRETE. POWER CO. PRIMARY FEEDER DUCT BANK WITH 42" MIN. RECEIVED
COVER . TERMINATE DUCT BANK AT PROPERTY LINE. TERMINATE
1-4/0 (CU) NEUTRAL CONCRETE ENCASEMENT 5'-0" OUTSIDE PROPERTY LINE FOR F.P.&L.
4/20/2023
INSULATED WIRE CO. EXTENSION OF PRIMARY CONDUITS. TERMINATE CONDUITS INSIDE
POWER COMPANY TRANSFORMER VAULT AND COORDINATE WITH
3" TRANSFORMER VAULT SPECIFICATIONS. PROVIDE LONG SWEEPS AS
SHOWN AND AS REQUIRED. FINAL ROUTING TO BE COORDINATED WITH
6" ARCHITECTURAL, CIVIL, MECHANICAL, PLUMBING & STRUCTURAL
2" DRAWINGS AND POWER CO. SERVICE REPRESENTATIVE IN THE FIELD.

PROPOSED MIXED-USE RENTAL DEVELOPMENT:


2"I.D. REFER TO SECTION A-A ON THIS SHEET FOR INSTALLATION DETAIL
N 6"
2"
5"I.D. APPROXIMATE LOCATION OF EXISTING POWER COMPANY MOUNTED
6" 3
(TYP.) TRANSFORMER FOR 120/208 VOLT, 3-PHASE, 4-WIRE ELECTRICAL

4101 SALZEDO STREET CORAL GABLES, FLORIDA 33146


3" SERVICE TO EXISTING 3-STORY OFFICE BUILDING TO REMAIN.
N CONTRACTOR TO PROVIDE PROTECTIVE BARRIERS AS REQUIRED TO
MAIN ELECTRICAL SERVICE TO EXISTING 3-STORY OFFICE BUILDING
DURING CONSTRUCTION OF PROPOSED 12-STORY MIXED-USE RENTAL
3" 2" 2" 2" 3" DEVELOPMENT. COORDINATE EXACT LOCATION IN THE FIELD

6" 6" 6" 6"


EXISTING 3-STORY

MERRICK 250
APPROXIMATE LOCATION OF EXISTING PULL BOX FOR ELECTRICAL
4
SERVICE TO REMAIN. COORDINATE EXACT LOCATION IN THE FIELD
OFFICE BUILDING DN

(RENOVATIONS UNDER APPROXIMATE ROUTING OF EXISTING CONCRETE ENCASED


POOL DECK AT 5TH 5
ELECTRICAL DUCT BANK TO REMAIN. COORDINATE EXACT ROUTING IN
A SEPARATE PERMIT)
FLOOR LEVEL THE FIELD. CONTRACTOR TO PROVIDE PROTECTIVE BARRIERS AS
REQUIRED TO MAIN ELECTRICAL SERVICE TO EXISTING 3-STORY
STREET LIGHTING ELECT. SERVICE OFFICE BUILDING DURING CONSTRUCTION OF PROPOSED 12-STORY
N LOAD CALCULATION MIXED-USE RENTAL DEVELOPMENT. COORDINATE EXACT LOCATION IN
THE FIELD
10 POLES AT 150 VA PER POLE: 1500 VA
X 1.25 D.F. 6 APPROXIMATE UNDERGROUND ROUTING OF EXISTING 6-4" E.C.
TOTAL LOAD = 1875 VA EXTEND EXISTING CONDUIT INTO POWER COMPANY
N AT 208 VOLT, 1-PHASE = 9.0 AMPS PER PHASE TRANSFORMER VAULT AND TERMINATE AS PER POWER COMPANY
DN TRANSFORMER VAULT SPECIFICATIONS. CONCRETE ENCASED
DN

4 THE ENTIRE SEGMENT OF DUCT BANK AS REQUIRED. PROVIDE


E PULL STRINGS ON EMPTY CONDUITS. PROVIDE ADDITIONAL PULL
4
PB

BOXES AS REQUIRED TO COMPLY WITH GENERAL NOTE NO.6


DN

6 SHOWN ON THIS SHEET. NEW PULL BOXES TO MATCH EXISTING.


NOTES FOR ELECTRICAL
PB

PB
E DN
E
APPROXIMATE LOCATION OF EXISTING PULL BOX FOR
RISER DIAGRAM:
DN

E 7
T

TELECOMMUNICATION SERVICES TO REMAIN. COORDINATE EXACT


6
LOCATION IN THE FIELD
1- PROVIDE 10 FT. SLACK ON EACH CABLE ENTERING
SALZEDO STREET

POWER CO. PAD TRANSFORMER VAULT.

AURORA STREET
8 7 8 APPROXIMATE UNDERGROUND ROUTING OF EXISTING 2-4" E.C.
2- ELECTRICAL SERVICE FOR STREET LIGHTING IS 120/208 AND 2-2" E.C. EXTEND EXISTING CONDUIT INTO MAIN TELEPHONE
VOLT, 1-PHASE, 3-WIRE. ROOM AND TERMINATE AS PER TELECOMMUNICATION UTILITY
5 COMPANY SHOP DRAWINGS FOR THIS PROJECT. CONCRETE
3- ALL ELECTRICAL EQUIPMENT INSTALLATION SHALL BE
ENCASED THE ENTIRE SEGMENT OF DUCT BANK AS REQUIRED.
INSTALLED ONE FOOT (1'-0") ABOVE THE MIN. FEMA
PROVIDE PULL STRINGS IN EMPTY CONDUITS. PROVIDE
N BASE FLOOD LEVEL. CONTRACTOR TO COORDINATE IN
10 ADDITIONAL PULL BOXES AS REQUIRED TO COMPLY WITH
THE FIELD.
GENERAL NOTE NO.6 SHOWN ON THIS SHEET. NEW PULL BOXES
4- PROVIDE SIGNAGE TO WARN OF POTENTIAL ELECTRIC TO MATCH EXISTING.
OUTDOOR TERRACE ARC FLASH HAZARDS AS PER N.E.C. ART. 110.16.
N NEW POLE MOUNTED LIGHT FIXTURE. INSTALL AND WIRE AS
AT 5TH FLOOR LEVEL 5- STREET LIGHT FIXTURES TO BE PROVIDED WITH 208 9
REQUIRED. REFER TO SHEET E-0.03 FOR LIGHT FIXTURE
VOLT BALLAST.
SPECIFICATION AND INSTALLATION DETAILS. PROVIDE PHOTOMETRIC
CALCULATION SHOP DRAWING SHOWING COMPLIANCE WITH CITY OF
CORAL GABLES STREET LIGHTING ILLUMINATION LEVELS.
2 16 COORDINATE FINAL LOCATION IN THE FIELD (TYPICAL)

10 2#8 COPPER USE/RHW (XLP) FOR HOT AND 1#10 COPPER THWN
(GROUND) IN 2"C. CONNECT TO COMBINATION MAIN DISCONNECT
13 SWITCH AND LIGHTING CONTACTOR AS REQUIRED
11 12
11 PROPOSED ELECTRICAL DISTRIBUTION EQUIPMENT FOR STREET
LIGHTING INSTALLATION. COORDINATE FINAL LOCATION IN THE
15 FIELD. INSTALL ON EXTERIOR WALL OF POWER COMPANY
N TRANSFORMER VAULT AS REQUIRED. REFER TO ELECTRICAL
RISER DIAGRAM SHOWN ON THIS SHEET FOR SPECIFICATIONS.
PROPOSED 12-STORY MIXED-USE RENTAL DEVELOPMENT 12 SELF-CONTAINED ELECTRIC METER, 120/208V, 1-PHASE, 3-WIRE,
1 GROUND FLOOR
100A IN NEMA 3R ENCLOSURE CLIENT INFORMATION:
N
COMBINATION LIGHTING CONTACTOR AND 250 VOLT, 2-POLE, 60 CORAL GABLES
13
14 10 AMP FUSIBLE MAIN DISCONNECT SWITCH WITH 2-20 AMP CURRENT
ROOF LEVEL LIMITING FUSES (100,000 A.I.C.) IN NEMA 3R ENCLOSURE, SERVICE
ALTA, LLC.
9 ENTRANCE RATED AND LOCKABLE COVER. SQUARE-D 2950 SW 27th AVE
NIGHT-MASTER SERIES OR ACCEPTABLE EQUAL. PROVIDE WITH SUITE 220
TX E
STREET LIGHTING PHOTOCELL OPTION. WIRE AS REQUIRED. EXTERNAL HANDLE
SHALL BE LOCKABLE IN THE "ON" AND "OFF" POSITION. ONE
MIAMI, FL 33133
PADLOCK, KEYED AS DIRECTED BY THE CITY OF CORAL GABLES
3
ELECTRICAL RISER DIAGRAM PUBLIC WORKS DIVISION. LABEL "STREET LIGHTING SERVICE MAIN
1 OF 1".
DATE:

22-MAR-2022 MTCI SUBMITTAL


SCALE: N.T.S 05-AUG-2022 PERMIT SET TO
14 3#6, 2"C TO POWER CO. TRANSFORMER VAULT. COORDINATE WITH CITY
POWER COMPANY FIELD REPRESENTATIVE PRIOR TO
INSTALLATION
N
15 1#8G (CU) TO 2-5/8" X 10'-0" LONG COPPERCLAD STEEL GROUND
N RODS. SPACED 8FT APART. MIN.

16 3#6, 2"C

PROJECT No. 19-017


ELECTRICAL SITE PLAN 0 5' 10' 20' 30' 40' DRAWN BY: JR/YG
CHECKED BY: JAR
SCALE: 1" = 20'-0" Scale: 1 INCH = 20 FOOT

E-1.00
ARCHITECTURE

FILE LOCATION:
C:\USERS\JOSE\VITAL ENGINEERING DROPBOX\JOSE RAMIREZ\PROJECTS\2021\21055 250 MERRICK RESIDENTIAL DEVELOPMENT\WORK DRAWINGS\E-0.00 SYMBOLS LEGEND, ELECTRICAL NOTES
& INDEX DRAWINGS.DWG

PRINTED ON:10.10.2022
ELECTRICAL NOTES LEGEND OF SYMBOLS GENERAL NOTES FOR LIGHT FIXTURES P L A N N I N G
ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE 2017 EDITION OF 26. CONTRACTOR'S WORK PRACTICES AND CONDITIONS MUST CONFORM WITH THE
SYMBOL DESCRIPTION SYMBOL DESCRIPTION 1. ALL WIRING CHANNELS (FLUORESCENT AND INCANDESCENT) AND BAFFLES I N T E R I O R S
1.
THE NATIONAL ELECTRICAL CODE (N.E.C.), 7TH EDITION OF THE 2020 FLORIDA OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970. LIGHTING:
SHALL BE COLD ROLLED STEEL OF MINIMUM GAUGE, OR AS REQUIRED BY
LOCAL CODE. CERTIFICATIO N No. AA0002451
BUILDING CODE (F.B.C.) AND ALL OTHER CODES AND ORDINANCES IN EFFECT AT 27. LOAD DATA IS BASED ON INFORMATION GIVEN TO THE ENGINEER AT THE TIME OF
THIS LOCATION. DESIGN. VERIFY ALL EQUIPMENT, PANEL AND WIRE SIZES BEFORE ORDERING. LIGHT FIXTURE, WALL MOUNTED AS INDICATED. 2. ALL SOCKETS SHALL BE OF THE PORCELAIN TYPE AND SHALL BE SECURELY
JUNCTION BOX. INSTALL AS SHOWN OR AS REQUIRED FOR MOTORIZED DAMPER. PROVIDE MOUNTED TO CHANNELS WITH SCREWS. SPRING MOUNTED SOCKETS ARE 4533 PONCE DE LEON BLVD.
2. DRAWINGS ARE DIAGRAMMATIC. DO NOT SCALE DRAWINGS FOR EXACT CONTRACTOR MUST PROVIDE ALL REQUIRED MODIFICATIONS TO THE M
1/2"C TO FIRE ALARM SYSTEM FOR CONTROLS. WIRE AS REQUIRED PER SMOKE EVACUATION Coral Gables, Florida 33146
LOCATION OF EQUIPMENT. THESE DRAWINGS ARE NOT INTENDED TO SHOW ELECTRICAL INSTALLATION TO COORDINATE WITH ACTUAL EQUIPMENT LIGHT FIXTURE, RECESSED OR SURFACE MOUNTED. NOT ACCEPTABLE. FIXTURE MANUFACTURER IS RESPONSIBLE FOR
SEQUENCE OF OPERATION. COORDINATE WITH MECHANICAL DRAWINGS. TEL: (305) 740-5442
EVERY MINOR DETAIL, BUT THE CONTRACTOR SHALL FURNISH AND INSTALL ALL PURCHASED SHOP DRAWINGS AT NO ADDITIONAL CHARGES TO SUPPLYING CORRECT SOCKETS FOR LAMPS INDICATED FOR USE IN
ITEMS REQUIRED FOR A COMPLETE AND ACCEPTABLE WORKING SCHEDULE. LIGHT FIXTURE, WALL MOUNTED AT 8'-0"A.F.F. UNLESS OTHERWISE INDICATED. FIXTURE. FAX: (305) 740-5443
THE CONTRACT. FSD
JUNCTION BOX. INSTALL AS SHOWN OR AS REQUIRED FOR FIRE/ SMOKE DAMPER. PROVIDE E-MAIL: info@beharfont.com
3. CHECK EQUIPMENT FOR PROPER VOLTAGE, PHASE, AND AMP RATING BEFORE 28. CONTRACTOR SHALL PAY FOR ALL PERMITS, FEES, INSPECTIONS AND TESTING; STRIP LIGHT FIXTURE, SURFACE MOUNTED. 3. ALL FIXTURE WIRING SHALL BE OF THE HEAT RESISTANT TYPE. AS
CONNECTION TO CIRCUITS. AND ALL REQUIRED INSURANCE SHALL BE PROVIDED FOR PROTECTION AGAINST 1/2"C TO FIRE ALARM SYSTEM FOR CONTROLS. WIRE AS REQUIRED PER SMOKE EVACUATION REQUIRED BY THE SPECIFICATIONS, OR AS REQUIRED BY LOCAL CODE.
PUBLIC LIABILITY AND PROPERTY DAMAGE FOR THE DURATION OF THE WORK. LIGHT FIXTURE IN EMERGENCY SYSTEM. SEQUENCE OF OPERATION. COORDINATE WITH MECHANICAL DRAWINGS. 4. FIXTURE MANUFACTURER AND CONTRACTOR SHALL BE RESPONSIBLE FOR © 2019 BEHAR FONT & PARTNERS P.A.
4. ALL CIRCUITS SHALL BE CLEARLY IDENTIFIED AND SHOWN ON PANEL THE DESIGN AND DRAWINGS FOR THIS
M.D. PROPER VENTILATION AND TEMPERATURE CONDITIONS OF LIGHT
DIRECTORIES. DO NOT CHANGE CIRCUIT ARRANGEMENT SHOWN ON THESE 29. JUNCTION BOXES SHALL BE GALVANIZED STEEL WITH SCREW OR HINGED JUNCTION BOX. INSTALL AS SHOWN OR AS REQUIRED FOR POWER EXTENSION TO OUTSIDE PROJECT ARE THE PROPERTY OF THIS

DRAWINGS. COVERS FOR INDOOR LOCATIONS AND WEATHER-PROOF WHERE EXPOSED TO AIR INTAKE MOTORIZED DAMPER. PROVIDE 1/2"C TO FAN COIL STARTING CONTACTOR. FIXTURES. ARCHITECT AND ARE PROTECTED UNDER THE
EMERGENCY LIGHTING UNIT, WALL MOUNTED. COPYRIGHT PROTECTION ACT.
WEATHER. OUTLET BOXES SHALL BE PRESSED STEEL IN DRY LOCATIONS. CAST INTERLOCK WITH RESPECTIVE FAN COIL UNIT AS REQUIRED FOR SIMULTANEOUS OPERATION. 5. ALL FIXTURES WITH REMOVABLE COVERS OR CONES SHALL BE SUPPLIED
5. ALL MATERIALS SHALL BE NEW AND SHALL BEAR THE UL LABEL WHEN
ALLOY WITH THREADED HUBS IN WET OR DAMP LOCATIONS AND SPECIAL LIGHT FIXTURE, RECESSED MOUNTED. COORDINATE WITH MECHANICAL DRAWINGS. WITH SAFETY CHAINS SECURELY ATTACHED TO MAIN HOUSINGS. THERE SEAL:
APPLICABLE.
ENCLOSURES FOR OTHER CLASSIFIED AREAS. SHALL BE A SUFFICIENT QUANTITY OF SAFETY CHAINS TO SUPPORT TOTAL
6. THE ELECTRICAL INSTALLATION SHALL MEET ALL STANDARD REQUIREMENTS OF A/C JUNCTION BOX. INSTALL AS SHOWN AS REQUIRED FOR CONTROL INTERCONNECTION
30. OUTLETS SHALL BE FLUSHED WITH FINISHED SURFACES. TWO OR MORE LIGHT LIGHT FIXTURE, STEM MOUNTED. WEIGHT OF FIXTURE.
THE POWER, TELEPHONE AND CABLE T.V. COMPANIES. CONTRACTOR SHALL SWITCHES IN SAME WALL SHALL BE INSTALLED IN GANG-TYPE BOXES. BETWEEN A/C FAN COIL UNIT AND CONDENSING UNIT. PROVIDE 1/2"C AND CONNECT AS 6. THE CONTRACTOR SHALL VERIFY WITH THE ARCHITECT AND/OR ENGINEER
COORDINATE SERVICE REQUIREMENTS WITH THE UTILITY COMPANIES. LIGHT FIXTURE, SURFACED MOUNTED. REQUIRED. COORDINATE EXACT LOCATION WITH MECHANICAL DRAWINGS. THAT ALL LIGHTING EQUIPMENT MEETS ALL NATIONAL AND LOCAL CODES
COORDINATE ALL BOX LOCATION WITH BUILDING ARCHITECTURAL FEATURES.
7. ALL CONDUCTORS SHALL BE IN CONDUIT. ALL SECTIONS OF METALLIC CONDUIT AS APPLICABLE, E.G. THERMAL PROTECTION AND U.L. LABEL. FIXTURES
31. PANELBOARDS SHALL BE DEAD FRONT CIRCUIT BREAKER TYPE WITH COPPER LIGHT FIXTURE, PENDANT MOUNTED. MOTOR, SIZE AS INDICATED ON DRAWINGS.
SYSTEM SHALL BE GROUNDED AND ELECTRICALLY CONTINUOUS. INSTALLED IN WET AND/OR DAMP LOCATIONS SHALL BE PROVIDED WITH
BUS AND AS SCHEDULED ON DRAWINGS. EACH PANELBOARD SHALL BE
8. RACEWAYS INSTALLED UNDERGROUND IN CONCRETE SLABS, AND/OR LARGER PROVIDED WITH A SEPARATE GROUND BUS IN ADDITION TO THE NEUTRAL BUS. LIGHT FIXTURE, RECESSED MOUNTED WITH SOLID LENS. COMBINATION EXHAUST FAN AND LIGHT U.L. LABEL IDENTIFYING FIXTURE IS SUITABLE FOR USE IN THE INSTALLED
G
THAN 2" IN DIAMETER SHALL BE GALVANIZED RIGID STEEL. PVC PIPE SCHEDULE CIRCUIT BREAKERS SHALL BE BOLT-ON AND HAVE A MINIMUM INTERRUPTING LOCATION.
40 IS ACCEPTABLE FOR UNDERGROUND INSTALLATION ONLY, IF APPROVED BY LIGHT FIXTURE, WALL MOUNTED ABOVE DOOR OR 8'-0"A.F.F. UNLESS OTHERWISE INDICATED. 7. CONTRACTOR SHALL SUBMIT FOR ACCEPTANCE OF THE ARCHITECT AND
RATING OF 10,000 AMPERES AT 120 VOLTS, 14,000 AMPERES AT 277 VOLTS. ALL FIRE ALARM SYSTEM:
LOCAL AUTHORITIES, UDNER PAVED AREAS IT SHALL BE ENCASED IN CONCRETE PANELS SHALL HAVE SNAP CATCH DOORS WITH CLEAR PLASTIC ENCLOSED THE ENGINEER, MANUFACTURER'S CATALOGUE SPECIFICATION SHEETS
WITH 24" MIN. COVER. RACEWAY 2 INCHES AND SMALLER IN DIAMETER SHALL BE TYPEWRITTEN DIRECTORY INSIDE. FOR ALL STANDARD CATALOGUE LIGHT FIXTURES PRIOR TO FABRICATION
LIGHT FIXTURE, RECESSED WALL WASHWER. F PULL STATION. WALL M0UNTED AT 48" A.F.F. WP WHERE REQUIRED. SEE FIRE ALARM
I.M.C. IF EXPOSED TO WEATHER, E.M.T. ELSEWHERE. FLEXIBLE CONDUIT USED OF THE SAME.
32. DRY TYPE TRANSFORMER SHALL BE 480 VOLTS DELTA PRIMARY, 208Y/ 120 VOLTS SYSTEM DWG.
JOSE A. RAMIREZ, P.E.
WHERE INDICATED SHALL BE METAL FOR INDOOR LOCATIONS, LIQUID-TIGHT FOR SECONDARY. THREE-PHASE, 60 HERTZ WITH FOUR 2-1/2% FCBN TAPS AND TWO LIGHT FIXTURE, RECESSED MOUNTED ON CONCRETE WALL . 8. FIXTURE MANUFACTURER AND/OR CONTRACTOR SHALL SUBMIT FOR P.E. 0060224
OUTDOOR LOCATIONS. USE STEEL COMPRESSION TYPE FITTING. D IONIZATION SMOKE DETECTOR ANALOG TYPE, CEILING MOUNTED. SEE FIRE ALARM SYSTEM ACCEPTANCE OF THE ARCHITECT AND THE ENGINEER, DETAILED CONSULTANT:
2-1/2% FCAN TAPS. KVA RATING SHALL BE AS SHOWN ON DRAWINGS.
9. JUNCTION BOX FOR LIGHTING FIXTURE DWG. DRAWINGS OF ALL SPECIAL DESIGN FIXTURES PRIOR TO FABRICATION OF
RACEWAYS INSTALLED IN OR THRU ANY CONCRETE SLABS BE SPACED A 33. DISCONNECT SWITCHES SHALL BE H.P. RATED, HEAVY DUTY, QUICK-MAKE, L
MINIMUM OF 3" DIA. OF THE LARGEST RACEWAY. METALLIC RACEWAYS SMOKE/HEAT PHOTOELECTRIC DETECTOR FOR ELEVATOR CAPTURE, CEILING MOUNTED. SEE THE SAME.
QUICK- BREAK, ENCLOSURE AS REQUIRED BY EXPOSURE. MOTOR STARTERS D
INSTALLED UNDERGROUND OR UNDER SLABS SHALL BE COATED WITH TWO E FIRE ALARM SYSTEM DWG. 9. ALL COMPONENT PARTS OF ARCHITECTURAL LIGHTING INSTALLATION
SHALL BE MANUAL OR MAGNETIC WITH OVERLOAD RELAYS IN EACH LEG. FUSES
COATS OF AN ASPHALTIC PAINT. SHALL BE PROVIDED BY GENERAL CONTRACTOR. COLOR AND FINISH
SHALL BE DUAL ELEMENT, COMBINING TIME DELAY WITH CURRENT LIMITING. L F JUNCTION BOX (LIGHTING AND FAN) D DUCT MOUNTED SMOKE DETECTOR. SEE FIRE ALARM SYSTEM DWG.
D SPECIFICATION SHALL BE BY THE ARCHITECT UNLESS OTHERWISE
10. CABLE AND WIRE INDICATED ON DRAWINGS SHALL BE 600 VOLT, COPPER, 34. ELECTRICAL CONTRACTOR SHALL PERFORM ALL NECESSARY WORK AND SHALL DESIGNATED IN THE LIGHTING FIXTURE SCHEDULE.
STRANDED, THHN/THWN INSULATION IN SIZES NO. 12 THRU NO. 8 AWG; AND PROVIDE ALL NECESSARY INSTRUMENTS AND SPECIAL APPARATUS TO CONDUCT
TAMPER SWITCH MONITOR MODULE. VERIFY QUANTITY AND LOCATION WITH MECHANICAL 10. THE CONTRACTOR SHALL VERIFY CEILING CONSTRUCTION FOR EACH
COPPER, STRANDED THW OR THWN INSULATION IN SIZES NO. 6 AWG AND ANY TEST THAT MAY BE REQUIRED TO INSURE THE SYSTEM IS FREE OF ALL TS
TRADE. SEE FIRE ALARM SYSTEM DWG. FIXTURE TYPE AND LOCATION AND SHALL COORDINATE TRIM DETAILS.
LARGER. MINIMUM SIZE WIRE SHALL BE NO. 12 AWG, MAXIMUM SIZE SHALL BE 600 IMPROPER GROUNDS AND SHORT CIRCUITS, AND THAT ALL FEEDERS ARE
MCM. PROPERLY BALANCED. FLOW SWITCH MONITOR MODULE.VERIFY QUANTITY AND LOCATION WITH MECHANICAL 11. BY SUBMITTING SHOP DRAWINGS, PRODUCT DATA, SAMPLES AND SIMILAR
TRACK LIGHT FIXTURE. FS
11. SEE MECHANICAL DRAWINGS FOR ELECTRICAL REQUIREMENTS AND LOCATION 35. WIRING DEVICES SHALL BE APPROVED SPECIFICATION GRADE. VERIFY LOCATION TRADE. SEE FIRE ALARM SYSTEM DWG. SUBMITTALS, THE CONTRACTOR REPRESENTS THAT THE CONTRACTOR
OF HVAC EQUIPMENT. THE CONTRACTOR SHALL PROVIDE ALL BRANCH CIRCUIT WITH ARCHITECTURAL DRAWINGS PRIOR TO ROUGH-IN. WIRING DEVICES SHALL HAS DETERMINED AND VERIFIED MATERIALS, FIELD MEASUREMENTS AND
LIGHT FIXTURE, POLE MOUNTED. R RELAY MODULE. SEE FIRE ALARM SYSTEM DWG. FIELD CONSTRUCTION CRITERIA RELATED THERETO, OR WILL DO SO, AND
AND CONTROL WIRING AS INDICATED AND REQUIRED, AND IN CONFORMANCE BE WHITE COLOR, DECORA TYPE.
WITH NEC ARTICLES 440, AND 725.26 (SEPARATE RACEWAYS) AND HAS CHECKED AND COORDINATED THE INFORMATION CONTAINED WITHIN
36. ELECTRICAL CONTRACTOR SHALL PROVIDE OUTLETS TO MATCH EQUIPMENT POLE MOUNTED LIGHT FIXTURE. S FIRE ALARM SPEAKER, CEILING MOUNTED, SEE FIRE ALARM SYSTEM DWG.
MANUFACTURER'S RECOMMENDATIONS. THERMOSTAT LOCATIONS ARE SHOWN SUCH SUBMITTALS WITH THE REQUIREMENTS OF THE WORK AND OF THE
PLUGS.
ON MECHANICAL DRAWINGS. MAKE CONNECTIONS AS REQUIRED BY CONTROL S CONTRACT DOCUMENTS.
37. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID BOLLARD LIGHT FIXTURE. FIRE ALARM SPEAKER, WALL MOUNTED AT 84" A.F.F. SEE FIRE ALARM SYSTEM DWG.
WIRING DIAGRAM. 12. UNLESS OTHERWISE SPECIFIED, VOLTAGES OF ALL LAMPS SHALL BE
INTERFERENCE WITH THE PROGRESS OF CONSTRUCTION. DETERMINED BY ELECTRICAL ENGINEER. ELECTRICAL CONTRACTOR
12. CIRCUITS ON THE DRAWINGS ARE TO DETERMINE LOAD DATA AND PANEL SIZE. L FIRE ALARM STROBE LIGHT, WALL MOUNTED AT 80" TO BOTTOM. SEE FIRE ALARM SYSTEM
38. CONTRACTOR SHALL DO HIS OWN CUTTING OF FLOOR AND WALLS AND DO ALL EXIT SIGN WALL MOUNTED LIGHT FIXTURE. DWG. SHALL COORDINATE PROPER LAMP BASE TYPES WITH SOCKET PROVIDED
THE CONTRACTOR SHALL PROVIDE CIRCUITS AND ROUTING OF CONDUITS TO
PATCHING ASSOCIATED WITH HIS/HER INSTALLATON. OBTAIN APPROVAL BEFORE IN SPECIFIED FIXTURE.
SUIT JOB CONDITIONS AND BALANCE THE JOB THROUGHOUT. SL FIRE ALARM SPEAKER/STROBE LIGHT COMBINATION. WALL MOUNTED AT 80" TO BOTTOM. SEE
DOING ANY CUTTING. REPAIR ANY DAMAGE DONE TO OTHER'S EQUIPMENT OR EXIT SIGN CEILING MOUNTED LIGHT FIXTURE (BOTH SIDE). 13. UNLESS OTHERWISE SPECIFIED, INITIAL PURCHASE OF LAMPS NOT EASILY
13. ROUTING OF RACEWAYS, INTERCONNECTING OUTLETS AND HOME-RUNS IS UP TO MATERIAL. FIRE ALARM SYSTEM DWGS.
THE ELECTRICAL CONTRACTOR, BUT AFTER COMPLETION OF THE INSTALLATION, AVAILABLE LOCALLY SHALL INCLUDE 100% SPARE QUANTITY OF LAMPS.
39. PROVIDE FIRE STOPPING MATERIAL AT ALL CONDUIT OPENINGS IN WALL AND SL FIRE ALARM SPEAKER/STROBE LIGHT COMBINATION. CEILING MOUNTED. SEE FIRE ALARM
CONTRACTOR SHALL SUBMIT TO THE OWNER AS-BUILT DRAWINGS OF THE EXIT SIGN CEILING MOUNTED LIGHT FIXTURE (ONE SIDE). 14. FIXTURE MANUFACTURER AND/OR CONTRACTOR SHALL BE RESPONSIBLE
FLOOR, AND OTHER LOCATIONS AS REQUIRED BY CODE TO PRESERVE FIRE SYSTEM DWGS.
ELECTRICAL WORK FOR FUTURE RECORD. THAT ALL FIXTURES SPECIFIED FOR EXTERIOR USE SHALL BE TREATED
RATING INTEGRITY.
WITH A WEATHER- RESISTANT CORROSION PROTECTIVE COATING.
14. CONTRACTOR SHALL VERIFY THE CEILING FINISHES AND SUSPENSION SYSTEM 40. CORRECTIONS OF ANY DEFECTS SHALL BE COMPLETED WITHOUT CHARGE AND SWITCH: H HEAT DETECTOR, CEILING MOUNTED. SEE FIRE ALARM SYSTEM DWG.
FOR SELECTION OF THE PROPER TRIM AND SUPPORT ARRANGEMENTS OF THE SHALL INCLUDE REPLACEMENT OR REPAIR OF ANY OTHER PHASE OF THE 15. ALL RECESSED LIGHT FIXTURES SHALL BE INSTALLED AT A MINIMUM OF 6"
FIXTURE. COORDINATE REQUIREMENTS WITH ARCHITECT. SINGLE POLE LIGHT SWITCH, QUIET TYPE, 120-277 VOLTS, 20 AMPS (15 AMPS FOR FIREFIGHTER'S TELEPHONE JACK, WALL MOUNTED AT 48" A.F.F. SEE FIRE ALARM SYSTEM AWAY FROM A/C DUCTS.
INSTALLATION WHICH MAY HAVE BEEN DAMAGED. F
NON-APPLIANCE CKTS. IN APT. UNITS). INSTALL 48"A.F.F. TO TOP. DWG. 16. RECESSED LIGHT FIXTURES INSTALLED IN 1-HOUR FIRE RATED CEILING
15. FURNISH AND INSTALL LIGHTING FIXTURES AND LAMPS AS CALLED FOR ON 41. CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP FREE OF
THESE DRAWINGS. DEFECT FOR A PERIOD OF NOT LESS THAN ONE YEAR FROM THE DATE OF 3 THREE WAY LIGHT SWITCH, QUIET TYPE, 120-277 VOLTS, 20 AMPS (15 AMPS IN APT. UNITS). EWL ELEVATOR'S WARNING LIGHT, WALL MOUNTED AT 48" A.F.F. SEE FIRE ALARM SYSTEM DWG. SHALL BE PROTECTED IN ACCORDANCE WITH THE CEILING U.L. DESIGN
CLASSIFICATION. RECEIVED
ACCEPTANCE. INSTALL 48"A.F.F. TO TOP. FCC
16. THE ELECTRICAL SYSTEM SHALL BE COMPLETELY AND EFFECTIVELY GROUNDED FIRE COMMAND CENTER, SEE FIRE ALARM SYSTEM DWG.
AS REQUIRED IN ARTICLE 250 OF THE NEC. PVC CONDUITS TO HAVE EQUIPMENT 42. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR ACCEPTANCE OF EVERY 4 FOUR WAY LIGHT SWITCH, QUIET TYPE, 120-277 VOLTS, 20 AMPS (15 AMPS IN APT. UNITS).
FTB FIRE/SMOKE DAMPER PROVIDE A RELAY CONTROL MODULE. SEE FIRE ALARM SYSTEM DWG.
4/20/2023
GROUND CONDUCTORS, AND WHEN CROSSING BUILDING EXPANSION JOINTS, EQUIPMENT AND MATERIAL USED, PRIOR TO ORDERING. INSTALL 48"A.F.F. TO TOP.
EXPANSION FITTINGS WITH BONDING JUMPERS SHALL BE USED. ALL GROUND 43. MOTORS: A. MOTORS 1/2 HORSEPOWER AND BELOW SHALL BE 120 VOLTS, SINGLE D DIMMER SWITCH, SINGLE POLE, WATT RATING TO MATCH LOAD. 120 VOLTS. INSTALL 48"A.F.F. FIRE TERMINAL BOX WITH CONTROL MODULES, SEE FIRE ALARM SYSTEM DWG.
CONNECTIONS TO BE DONE AS PER LATEST EDITION OF NATIONAL ELECTRICAL PHASE. B. MOTORS OF 1/2 HORSEPOWER AND LARGER SHALL BE AS SCHEDULED. TO TOP.
CODE. C. PROVIDE DISCONNECTS FOR ALL MOTORS TO BE INSTALLED. M MANUAL MOTOR STARTER SWITCH, SINGLE POLE WITH OVERLOAD PROTECTION. INSTALL D DUCT MOUNTED SMOKE DETECTOR. SEE FIRE ALARM SYSTEM DWG.
D
17. ELECTRICAL EQUIPMENT AIC RATING AND FEEDER SIZES SHOWN ON THESE 44. STANDARDS FOR MATERIALS. ALL MATERIALS SHALL BE NEW AND SHALL 48"A.F.F. OR AS REQUIRED.
PLANS ARE DESIGNED FOR MAXIMUM AVAILABLE FAULT CURRENT AND MAXIMUM
H FIXED TEMPERATURE (13DEGREES) HEAT DETECTOR. SEE FIRE ALARM SYSTEM DWG.
CONFORM TO THE APPLICABLE STANDARDS WHERE SUCH HAVE BEEN H
COMBINATION THERMOSTAT AND HUMIDITY CONTROL. INSTALL AT 48" A.F.F.

PROPOSED MIXED-USE RENTAL DEVELOPMENT:


ALLOWABLE VOLTAGE DROP RESPECTIVELY. ESTABLISHED FOR THE PARTICULAR MATERIAL IN QUESTION. THE PUBLICATIONS SMOKE DETECTOR, WALL OR CEILING MOUNTED. 120 VOLTS AND BATTERY BACK UP, WHIT
D D
18. THE PROJECT IS "NEW CONSTRUCTION". THE CONTRACTOR SHALL VISIT THE JOB OS DECORA TYPE COMBINATION SINGLE POLE LIGHT SWITCH WITH INFRARED OCCUPANCY A
AND STANDARDS OF THE ORGANIZATIONS BELOW ARE APPLICABLE TO VISIBLE "POWER ON' INDICATOR, TEST BUTTON, SELF COTAINED, SOUNDING DEVICE (MIN.
SITE TO DETERMINE THE EXTENT OF WORK INVOLVED WITH THESE DOCUMENTS MATERIALS SPECIFIED HEREIN. SENSOR. WIRE TO LIGHT FIXTURE AS PER MANUFACTURER'S WIRING DIAGRAM, AS SHOWN RATING 85 dbA AT 10'-0"). SEE APARTMENT'S GENERAL NOTE #8.
AS SHOWN. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY ALL A. AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM) AND AS REQUIRED. PROGRAM AUTOMATIC TIME SETTING TO TURN LIGHTING OFF WITHIN 30
D D COMBINATION SMOKE/CARBON MONOXIDE DETECTOR, WALL OR CEILING MOUNTED, 120
EXISTING CONDITIONS AND ALLOW FOR ANY CHANGES THAT MAY BE MADE B. UNDERWRITER'S LABORATORIES, INC. (UL) MINUTES OF AN OCCUPANT LEAVING THE AREA WATT RATING TO MACH LOAD. LEVITON CAT. B VOLTS AND BATTERY BACKUP WITH VISIBLE POWER "ON" INDICATOR, TEST BUTTON AND

4101 SALZEDO STREET CORAL GABLES, FLORIDA 33146


DURING THE COMPLETION OF THE PROJECT. ANY ELECTRICAL WORK THAT MAY C. AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI) NO. OSSMT OR EQUAL INSTALL 48" A.F.F.
SELF-CONTAINED, SOUNDING DEVICE (MIN. RATING 85 DBA AT 10'-0"). SEE APARTMENT'S
HAVE TO BE DONE TO COMPLETE ANY ALTERATIONS SHOWN ON ANY PLAN SHALL D. NATIONAL ELECTRICAL MANUFACTURER'S ASSOCIATION (NEMA) OS DECORA TYPE COMBINATION SINGLE POLE FAN SWITCH WITH INFRARED OCCUPANCY GENERAL NOTE #17.
BE INCLUDED IN THIS CONTRACT WITH NO ADDITIONAL CHARGES TO THE OWNER E. NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) F
AFTER THE CONTRACTS ARE LET. SENSOR. WIRE TO EXHAUST FAN AS PER MANUFACTURER'S WIRING DIAGRAM, AS SHOWN C0 C0 CARBON MONOXIDE DETECTOR, WALL OR CEILING MOUNTED, 120 VOLTS AND BATTERY
WHERE REFERENCE IS MADE TO TRADE NAMES OR NAMES OF MANUFACTURER'S
AND AS REQUIRED. PROGRAM AUTOMATIC TIME SETTING TO TURN EXHAUST FAN OFF WITHIN BACKUP WITH VISIBLE POWER "ON" INDICATOR, TEST BUTTON AND SELF-CONTAINED,
19. THE CONTRACTOR SHALL FURNISH ALL LABOR MATERIALS AND EQUIPMENT SUCH REFERENCES ARE MADE SOLELY TO DESIGNANTE AND TO IDENTIFY
30 MINUTES OF AN OCCUPANT LEAVING THE AREA WATT RATING TO MACH LOAD. LEVITON SOUNDING DEVICE (MIN. RATING 85 DBA AT 10'-0"). SEE APARTMENT'S GENERAL NOTE #17.
REQUIRED FOR A COMPLETE ELECTRICAL INSTALLATION IN ACCORDANCE WITH QUALITY OF MATERIALS OR EQUIPMENT TO BE FURNISHED AND DOES NOT
CAT. NO. OSSMT OR EQUAL INSTALL 48" A.F.F.
THESE DRAWINGS. PRECLUDE THE USE OF 'EQUAL' EQUIPMENT AS APPROVED BY THE ENGINEER. DH MAGNETIC DOOR HOLDER. SEE FIRE ALARM SYSTEM DWG.

MERRICK 250
20. PROVIDE TEMPORARY POWER AND LIGHT OUTLETS AND ALL REQUIRED CONNEC- OS CEILING OR WALL MOUNTED MULTI-TECHNOLOGY OCCUPANCY SENSOR RATED AT 24 VOLTS.
OS
45. WORKMANSHIP. ALL WORK SHALL BE INSTALLED IN A NEAT, ORDERLY MANNER.
TIONS FOR USE BY OTHER TRADES. WIRE IN SERIES WITH LIGHT SWITCHES LIGHT FIXTURES CONNECTED TO NORMAL POWER DC DOOR CONTACT SWITCH.
DEVICES, PLATES, EXPOSED. RACEWAYS, ENCLOSURES, COVERS, FIXTURES, ETC
21. OUTDOOR UNDERGROUND CONDUITS SHALL BE SCHEDULE 40 PVC. UNDER ONLY IN RESPECTIVE AREAS AND AS PER MANUFACTURER'S WIRING DIAGRAM. LEVITE
SHALL BE ALIGNED PERPENDICULAR TO/OR PARALLEL WITH THE PRINCIPAL KP KEY PAD. INSTALL 48" A.F.F.
PAVED AREAS IT SHALL BE ENCASED IN CONCRETE, MINIMUM COVER SHALL BE STRUCTURE MEMBERS. THE EDGES OF THESE COVERS, PLATES, ENCLOSURES, CATALOG NO. OSC20-MOW OR EQUAL. PROVIDE POWER PACK RATED AT 13 AMPS, QUANTITY
24". AS REQUIRED. LEVITE CATALOG NO. OSP20-120 OR EQUAL. PROGRAM AUTOMATIC TIME DOOR CHIME. INSTALL 7'-6" A.F.F. UNLESS OTHERWISE INDICATED.
ETC. SHALL BE IN VERTICAL OR HORIZONTAL PLANE, AS APPLICABLE FOR THE RECEPTACLES:
22. ELECTRICAL INSTALLATION SHALL CONFORM TO THE REQUIREMENTS OF N.E.C. SETTING TO TURN LIGHTING OFF WITHIN 30 MINUTES OF AN OCCUPANT LEAVING THE AREA.
PARTICULAR ITEM INVOLVED. EXPOSED RACEWAYS SHALL BE OFFSET WHERE PUSH BUTTON. INSTALL 48" A.F.F.
110-26 (A)(1) "WORKING SPACES" AND N.E.C. 408 "SWITCHBOARDS AND THEY ENTER SURFACE-MOUNTED EQUIPMENT. WIRING INSTALLED IN PLANELS
PANELBOARDS" INCLUDING SPACES ABOVE THE EQUIPMENT. AND OTHER ENCLOSURES SHALL BE NEATLY LOOPED AND LACED AND NOT I INTERCOMM. INSTALL 48" A.F.F.
23. PROVIDE FIELD MARKING TO WARM PERSONNEL OF POTENTIAL ELECTRIC ARC WADDED OR BUNDLED. DUPLEX RECEPTACLE OUTLET, 125 VOLTS, 3-WIRE, GROUNDING TYPE TAMPER RESISTANT, 20
FLASH HAZARDS IN ACCORDANCE WITH N.E.C. ART. 110-16. AMPS (15 AMPS FOR NON-APPLIANCE CKTS. IN APT. UNITS). INSTALL 18"A.F.F. TO CENTER MISCELLANEOUS:
46. COORDINATED SHOP DRAWINGS: SUBMIT COORDINATED SHOP DRAWINGS AT UNLESS OTHERWISE INDICATED.
24. PRIOR TO INSTALLATION OF ROUGH ELECTRIC WIRING CHECK NAMEPLATE DATA 1/2-INCH SCALE, NOT REDUCED, USING ACTUAL SIZES AND WEIGHTS OF CONDUIT RUN CONCEALED IN CEILING OR WALL.
OF A/C EQUIPMENT, HOT WATER HEATERS, ELEVATORS AND OTHER EQUIPMENT DUPLEX RECEPTACLE OUTLET, 125 VOLTS, 3-WIRE, GROUNDING TYPE RESISTANT, 20 AMPS (15
VENDOR'S EQUIPMENT. PLANS SHALL CONSIST OF FLOOR PLAN AND ELEVATIONS AMPS FOR NON-APPLIANCE CKTS. IN APT. UNITS). INSTALL 44"A.F.F. TO CENTER. CONDUIT RUN UNDERGROUND OR IN FLOOR SLAB.
TO OBTAIN CORRECT WIRE SIZES AND OVERCURRENT DEVICE SIZES. OF EACH SIGNIFICANT WALL. DUCTS OR FOREIGN PIPES MAY NOT ENCROACH
OVER PANELS AND SWITCHBOARDS. SHOW NEC REQUIRED CLEARANCES. UPON SINGLE RECEPTACLE OUTLET, 125 VOLTS, 3-WIRE, GROUNDING TYPE, 20 AMPS. INSTALL CONDUIT UP.
25. IF, THROUGH ERRORS OR OMISSIONS, THE INTENT TO THE ARCHITECT/ENGINEER
COMPLETION OF THE PROJECT THE PLANS SHALL BE UPDATED WITH INCIDENTAL 18"A.F.F. TO CENTER UNLESS OTHERWISE INDICATED.
WITH REGARD TO ANY DETAIL IS NOT CLEAR, OR IS CAPABLE OF MORE THAN ONE CONDUIT DOWN.
INTERPRETATION, SUCH MATTERS SHALL BE BROUGHT TO THE ATTENTION OF ITEMS SUCH AS RELAYS, TIME CLOCKS, CONTACTORS, ETC. DUPLEX RECEPTACLE OUTLET WITH TOP RECEPTACLE SWITCHED, 120 VOLTS, 3-WIRE,
GROUNDING TYPE TAMPER RESISTANT, 15 AMPS. INSTALL 18"A.F.F. TO CENTER. FLEXIBLE CONDUIT.
ARCHITECT/ENGINEER IN WRITING BEFORE THE SUBMISSION OF BIDS, AND THE
ARCHITECT/ENGINNER SHALL MAKE CORRECTION OR EXPLANATION IN WRITING. 47. ALL EMERGENCY SYSTEM, DISCONNECTS FEEDERS, BRANCH CIRCUITS SHALL HOME-RUN TO ELECTRIC PANEL. HATCH MARKS INDICATE NUMBER OF WIRES, - DENOTES
USB CHARGER/DUPLEX RECEPTACLE OUTLET, 125 VOLTS, 3-WIRE, GROUNDING TYPE 20AMPS
OTHERWISE, NO EXTRA CHARGE WILL BE ALLOWED FOR THE WORK OR MATERIAL COMPLY WITH NEC 700.10(A)(B)(C)(D).” GROUND WIRE.
(15 AMPS FOR NON-APPLIANCE CKTS. IN APT. UNITS). INSTALL 44"A.F.F. TO CENTER.
WHICH THE ARCHITECT/ENGINEER WILL REQUIRE, PROVIDED THAT IT COMES 2 60
0 DISCONNECT SWITCH. 2-NUMBER OF POLES; 60-FRAME SIZE; 0-NO FUSE (FUSE SIZE).
QUADRUPLEX RECEPTACLE OUTLET, 125 VOLTS, 3-WIRE, GROUNDING TYPE TAMPER
WITHIN A RESONABLE INTERPRETATION OF THE DRAWINGS AND SPECIFICATIONS.
RESISTANT, 20 AMPS. INSTALL 18"A.F.F. TO CENTER UNLESS OTHERWISE INDICATED. A
LIGHTING FIXTURE IDENTIFICATION. A-DENOTES TYPE; 3-DENOTES QUANTITY OF FIXTURES IN
3 THE AREA.
SPECIAL RECEPTACLE OUTLET, 250 VOLTS, 4-WIRE, GROUNDING TYPE, AMPS AS SHOWN.
INSTALL 18" A.F.F. TO CENTER UNLESS OTHERWISE INDICATED. VFD MOTOR STARTER, BY MECHANICAL CONTRACTOR OR LIGHTING CONTRACTOR.
LIST OF DRAWINGS DUPLEX RECEPTACLE. INSTALL FLUSH AT FLOOR. TIME CLOCK. INSTALL AS REQUIRED.
01 E-0.00 SYMBOLS LEGEND, ELECTRICAL NOTES & INDEX DRAWINGS GENERAL NOTE FOR OCCUPANCY SENSORS FOR LIGHTING: EV1 W/P SINGLE PORT ELECTRIC VEHICLE CHARGING STATION; W/P- DENOTES (W) WALL MOUNTED OR
ELECTRICAL PANEL.
02 E-0.01 MISCELLANEOUS DETAILS (P) BOLLARD FLR. MOUNTED
03 E-0.02 MISCELLANEOUS DETAILS 1- OCCUPANCY SENSORS FOR LIGHTING ON ALL FLOORS NEED TO MEET THE PLYWOOD BOARD FOR TELEPHONE AND CABLE T.V. SYSTEMS.
REQUIREMENTS OUTLINED IN NFPA 101, 7.8.1.2.2 AND NEED TO BE TIED IN TO EV2 W/P DUAL PORT ELECTRIC VEHICLE CHARGING STATION; W/P- DENOTES (W) WALL MOUNTED OR
04 E-0.03 MISCELLANEOUS DETAILS THE FIRE ALARM SYSTEM. (P) BOLLARD FLR. MOUNTED STRIP HEATER.
05 E-0.04 EMERGENCY GENERATOR SPECIFICATIONS AND DETAILS
2- OCCUPANCY SENSORS SHALL ONLY CONTROLLED LIGHT FIXTURES ABBREVIATIONS:
06 E-1.00 ELECTRICAL SITE PLAN DATA:
CONNECTED TO NORMAL POWER. EMERGENCY LIGHTS AND EXIT LIGHTS
07 E-1.01A GROUND LEVEL SECTOR 'A' ELECTRICAL PLAN CONNECTED TO GENERATOR SYSTEM SHALL NOT BE CONTROLLED BY
M MAIN TELEPHONE OUTLET. A.F.F. ABOVE FINISHED FLOOR.
08 E-1.01B GROUND LEVEL SECTOR 'B' ELECTRICAL PLAN OCCUPANCY SENSORS.
09 E-1.01C RESERVED TELEPHONE OUTLET. INSTALL 18"A.F.F. TO CENTER UNLESS OTHERWISE INDICATED. W.P. WEATHER PROOF.
10 E-1.02A SECOND LEVEL SECTOR 'A' ELECTRICAL PLAN CABLE T.V. OUTLET. INSTALL 18"A.F.F. TO CENTER UNLESS OTHERWISE INDICATED. W.R. WEATHER RESISTANT.
11 E-1.02B SECOND LEVEL SECTOR 'B' ELECTRICAL PLAN COMBINATION TELEPHONE/COMPUTER DATA AND T.V. OUTLET. INSTALL 18" A.F.F. TO CENTER G.F.I. GROUND FAULT INTERRUPTER.
12 E-1.03A THIRD LEVEL SECTOR 'A' ELECTRICAL PLAN UNLESS OTHERWISE INDICATED.
V.P. VAPOR PROOF.
13 E-1.03B THIRD LEVEL SECTOR 'B' ELECTRICAL PLAN COMPUTER DATA OUTLET. INSTALL 18" A.F.F. TO CENTER UNLESS OTHERWISE INDICATED. W.T. WATER TIGHT
14 E-1.04A 4TH LEVEL SECTOR 'A' ELECTRICAL PLAN COMBINATION TELEPHONE OUTLET AND COMPUTER DATA OUTLET. INSTALL 18" A.F.F. TO E.W.C. ELECTRIC WATER COOLER.
15 E-1.04B 4TH LEVEL SECTOR 'B' ELECTRICAL PLAN CENTER UNLESS OTHERWISE INDICATED.
P.H. PHOTOCELL.
16 E-1.05A 5TH LEVEL SECTOR 'A' ELECTRICAL PLAN JUNCTION BOX. INSTALL AS SHOWN OR AS REQUIRED.
17 E-1.05B 5TH LEVEL SECTOR 'B' ELECTRICAL PLAN A.F.C.I. ARC FAULT CIRCUIT INTERRUPTER.
18 E-1.06 TYPICAL LEVEL (FROM 6TH THRU 12TH LVS.) ELECTRICAL PLAN W.L. DENOTES WITH WET LOCATION LABEL.
19 E-1.07 ROOF LEVEL ELECTRICAL PLAN E.C. EMPTY CONDUIT.
20 E-1.08 LIGHTNING PROTECTION SYSTEM
21 E-1.09 GROUND LEVEL PHOTOMETRIC PLAN
22 E-1.10 SECOND LEVEL PHOTOMETRIC PLAN
23 E-1.11 THIRD LEVEL PHOTOMETRIC PLAN
24 E-1.12 FOURTH LEVEL PHOTOMETRIC PLAN CLIENT INFORMATION:
25 E-1.13 RESERVED CORAL GABLES
26 E-2.00 PANEL SCHEDULES
ALTA, LLC.
27 E-2.01 PANEL SCHEDULES
28 E-2.02 PANEL SCHEDULES
2950 SW 27th AVE
29 E-2.03 PANEL SCHEDULES SUITE 220
30 E-2.04 RESERVED MIAMI, FL 33133
31 E-3.00 HOUSE LOAD ELECTRICAL RISER DIAGRAM DATE:
32 E-3.00A RESERVED
22-MAR-2022 MTCI SUBMITTAL
33 E-3.01 APARTMENT LOAD ELECTRICAL RISER DIAGRAM
17-JUNE-2022 MTCI REVIEW
34 E-3.01A RESERVED COMMENTS
35 E-3.02 FIRE ALARM SYSTEM RISER DIAGRAM 29-JULY-2022 COORD.
36 E-3.03 TELEPHONE AND CABLE TV SYSTEM RISER DIAGRAM REVISION
37 E-3.04 BI-DIRECTIONAL DISTR. ANTENNA SYST. RISER DIAGRAM 05-AUG-2022 PERMIT SET TO
CITY
38 E-4.00 ENLARGED PLANS - ELECTRICAL ROOMS
39 E-4.01 ENLARGED PLANS - ELECTRICAL ROOMS
40 E-4.02 ENLARGED PLANS - ELECTRICAL ROOMS
41 E-4.03 ENLARGED PLANS - 'ELEVATORS', NOTES AND DETAILS
42 E-4.04 ENLARGED PLAN - LOBBY AREA (LIGHTING)
43 E-4.05 ENLARGED PLAN - LOBBY AREA (POWER)
44 E-4.06 ENLARGED PLANS - GROUND LEVEL (LIGHTING AND POWER PLANS)
45 E-4.07 ENLARGED PLANS - SECOND LEVEL (LIGHTING)
46 E-4.08 ENLARGED PLANS - SECOND LEVEL (POWER)
47 E-4.09 ENLARGED PLANS - MULTIPURPOSE( LIGHTING AND POWER PLANS)
48 E-5.00 ENLARGED PLANS - TYPICAL UNITS
49 E-5.01 ENLARGED PLANS - TYPICAL UNITS
50 E-5.02 ENLARGED PLANS - TYPICAL UNITS
51 E-5.03 ENLARGED PLANS - TYPICAL UNITS
52 E-6.00 250 BIRD ROAD OFFICE BUILDING - ELECTRICAL RISER DIAGRAM (FOR
REFERENCE ONLY)
53 E-6.01 250 BIRD ROAD OFFICE BUILDING - PANEL SCHEDULES (FOR REFERENCE PROJECT No. 19-017
ONLY)
DRAWN BY: JR/YG
CHECKED BY: JAR

E-0.00