You are on page 1of 2

ARKIFLOOR EH

Two-component, solvent-based, epoxy floor coating system

PRODUCT DESCRIPTION TECHNICAL PROPERTIES

Arkifloor EH is a colour pigmented, two-component DESCRIPTION RESULTS


epoxy floor coating system. It is designed for light to
medium-grade traffic and corrosion control environment. Adhesion Strength
2.5 N/mm2
Arkifloor EH displays good adhesive properties, and JIS A 6909 5.5
excellent resistance against chemicals on well prepared
cementitous substrates. Abrasion Resistance 30 mg
Taber Test: CS17 (1000 rounds)
The gloss finish of Arkifloor EH retards the growth of
mould and fungus commonly found on substrates. Its Anti-slip Coefficient 0.26
smooth, hard surface prevents the development of dust JIS A 1407
from abrasion and easy for maintenance. With Hardness
broadcast of silica sand, a textured effect with anti-slip 83
Shore D Hard Scale
coating can be produced.
Impact Resistance
No
Arkifloor EH is particularly suitable for storage areas, JIS K 5400 8.3.2 Dupont test : peeling /
AHU rooms, walkways, lobby floors, stairways, Dropping 500g of steel ball from 50 cracks
balconies, corridors, as well as vicinities of industrial, cm height
trading and commercial building areas with light
mechanical loads. Tensile Strength and Elongation to
Break 13.05
N/mm2
Arkifloor EH comes in a wide range of colors for your ASTM D882:92a
flooring needs. For standard colors, please refer to our Odor Low
Color Chart. Special color requests are available on
request. Thermal Resistance Approx. 50oC
Physically
Toxicity
safe
FEATURES

 Excellent resistance to a wide range of chemicals and SURFACE PREPARATION


oil spills Concrete Substrate
 Dust-proofing capability, reduces floor maintenance Concrete surfaces should be well cured and free from
 Strong and durable with seamless finish dirt, dust, oil, grease and foreign matters. Any unsound
 Excellent impact and abrasion resistance for light to substrates, cracks, and pot-holes should be made good
medium vehicular movement with the appropriate SKK filler product.
 Easy mixing and application at site
Concrete is highly susceptible to uprising moisture,
 Enhances the appearance of the indoor environment
which can decrease the effectiveness of any coating
 Retards the growth of bacteria and mould system. Installation of a water-proofing membranes
 Non-slip finish available mandatory to prevent glitches in the dynamics of any
coating system. Smooth concrete surfaces may have to
PHYSICAL PROPERTIES be chemically cleaned or mechanically scarified to
provide bonding keys before the coating can be laid.
Color Wide range Etching neutralizes the alkaline surface and provides a
Finish Gloss better bond. It also helps remove salt deposits or
laitance that can occur on concrete surfaces.
Film Thickness Wet Film : 350 microns
Dry Film : 300 microns Masonry and Mortar Substrate
Masonry surfaces may peel due to efflorescence, where
Flash Point 10 C
o
soluble salts are present. It is therefore essential to
Loading Capacity Surface Dry : 8 hrs treat the surfaces free from dirt, dust, oil, grease and
(30oC) Fully Cured : 7 days foreign matters. Environmental determinants like
Pot Life (30oC) humidity can also cause structural or superficial cracks
Approx. 30 mins
with mortar estoration work should be carried out to
Volume Solid 87 ± 3% amend these problems prior to the application of paint. If
efflorescence is also evident, it must be removed before
Shelf Life repainting. Remove all flaking or chalking paint from the
Up to 6 months
(in sealed container) damaged area by wire brushing or sandblasting. If
Specific Gravity Approx. 1.5 surface is very porous, apply SK Floor Filler, an epoxy
resin-based cementitious conditioner to mend the
surface.

1/2
ARKIFLOOR EH
Two-component, solvent-based, epoxy floor coating system

APPLICATION PROCEDURES CHEMICAL RESISTANCE

 MIXING Resistance to splash or


Slight
spillage of industrial No
Degradation/
chemicals at ambient Degradation
Mixing Ratio (by weight ratio) Discoloration
temperatures
Base Hardener
INORGANIC ACIDS
100 25
50% Sulfuric Acid ♦
37% Hydrochloric Acid ♦
The base and hardener should be stirred thoroughly
50% Nitric Acid ♦
prior to use whether the application will be by roller or
airless spray. Do not allow material ponding. 50% Phosphoric Acid ♦
ORGANIC ACIDS
APPLICATION 10% Lactic Acid ♦
5% Formic Acid ♦
Ensure that substrate surface is cleaned prior to 10% Acetic Acid ♦
priming. Apply one coat of SK Arkiprimer and two ALKALINE
coats of Arkifloor EH over the substrate by roller or
30% Calcium Chloride ♦
brush. After allowing adequate curing, the surface
20% Potassium Chloride ♦
should be inspected for runs, foreign matter and under
Saturated Calcium ♦
cured areas. Do not apply Arkifloor EH at temperature Hydroxide
25% Ammonia ♦
below 10oC.
50% Sodium Hydroxide ♦
10% Sodium Hypochlorite ♦
Coverage
Per Coat 90 - 110 m2 (or 0.2kg/m2) ORGANIC SOLVENT
Overcoating Interval 8 hrs, max 3 days Methyl Alcohol ♦
No. of Coats 2 Toluene ♦
Petrol ♦
 PACKING STYLE AQUEOUS SOLUTION
Water ♦
Arkifloor EH (20 kg/set) Sugar Solution ♦
Arkifloor EH Base 16 kg can 10% Sodium Chloride ♦
Arkifloor EH Hardener 4 kg can
CLEANING
MATERIAL HANDLING
Tools must be cleaned immediately after use with SKK
Always wear the appropriate safety goggles, breathing Thinner.
protection, clothing and gloves during the handling of
epoxy resins and hardeners. Work with adequate SAFETY PRECAUTIONS
ventilation during application. Any sources of ignition This product contains volatile and inflammable solvents
should be eliminated and only use equipment and must not be used near flame or welding operations.
incorporated with explosion protection. Do not smoke. Avoid contact with skin or eye. Any skin or eye
Store all materials in a cool, well-ventilated and dry contamination should be washed immediately with
place, away from direct sunlight. Properly dispose all plenty of water and seek medical treatment. If
used containers and excess materials in accordance to swallowed, do not induce vomiting. Contact a physician
the local governing safety rules and regulations. immediately.

The technical information given herein is of a general nature


and correct to the best of our knowledge based on laboratory
tests and professional experiences. It shall not to be construed
as implying any guarantee of performance. Due to
unforeseeable conditions and constraints, we will not assume
liability for the unsuccessful use of this product. We reserve the
right to alter or modify any data given without prior notice.
When in doubt, please consult our technical department for
further information.

2/2

You might also like