PROPOSED ENHANCEMENT OF EXISTING MAIN SWITCHBOARD (MSB) AT SELECTED TOLL PLAZA’S OF

NORTH-SOUTH EXPRESSWAY

TECHNICAL DATA

NO. DESCRIPTION BRAND ORIGIN


1. Main Switchboard Delta Saujana Malaysia
2. Auto Transfer Switch ABB Korea
3. Air Circuit Breaker Terasaki China
4. Moulded Case Circuit Breaker Terasaki China
5. Earth Fault & Over Current Mikro Malaysia
6. Ammeter WL&L China
7. Voltmeter WL&L China
8. Frequency Meter WL&L China
9. Power Factor Meter WL&L China
10. Kilowatt Meter WL&L China
11. Kilowatt Hour Meter EMES China
12. Hour Run Meter Camsco Taiwan
13. Power Factor Regulator Mikro Malaysia
14. Fuse Switch ABB Korea
15. Capacitor Bank ELCO US
16. Capacitor Switching Contactor ELCO US
17. Current Transformer EP China
Company Profile:
Switchboard Manufacturer
KEJURUTERAAN ELEKTRIK DELTA SAUJANA SDN. BHD.

(869311-P)

KEJURUTERAAN ELEKTRIK DELTA SAUJANA SDN. BHD.


LOT 19, JALAN PAHAT 16/8A, SEKSYEN 16,
40200 SHAH ALAM,SELANGOR.

Email : desana31@gmail.com
TEL: 03-5511 4086 (Hunting Line) FAX: 03-5511 4087
KEJURUTERAAN ELEKTRIK DELTA SAUJANA SDN. BHD.

(869311-P)
CONTENTS
 COMPANY SUMMARY
 EXECUTIVE SUMMARY
 SURUHANJAYA SYARIKAT MALAYSIA
 KEMENTERIAN KEWANGAN MALAYSIA
 SURUHANJAYA TENAGA
 SIRIM IP55 TEST REPORT CERTIFICATE
 PERAKUAN PENDAFTARAN CIDB
 PUSAT KHIDMAT KONTRAKTOR
 PERAKUAN KEKOMPETENAN SEBAGAI
PENJAGA JENTERA
 PERAKUAN KEKOMPETENAN SEBAGAI
PENDAWAI
 ORGANIZATION CHART
 SELECTION CRITERIA COMMERCIAL
 PRODUCTION EQUIPMENTS
 COMPANY PRODUCTS
 TYPE TEST
 CUSTOMER REFERENCE
 LOCATION MAP
KEJURUTERAAN ELEKTRIK DELTA SAUJANA SDN. BHD.

(869311-P)
COMPANY SUMMARY
COMPANY NAME : KEJURUTERAAN ELEKTRIK DELTA SAUJANA SDN. BHD.

NATURE OF BUSINESS : GENERAL AND ELECTRICAL ENGINEERS, ELECTRICIANS, WORKERS,


REPAIRES, DEALERS, DISTRIBUTORS, AGENTS AND CONTRACTOR
WORKS RELATED TO THE USAGE OF ELECTRICITY, SWITCHBOARD,
PARTS AND ACCESSORIES, ELECTRICAL EQUIPMENT AND
ELECTRICAL SYSTEMS.

ADDRESS : LOT 19, JALAN PAHAT16/8A, SEKSYEN 16,


40200 SHAH ALAM, SELANGOR DARUL EHSAN.

EMAIL ADDRESS : desana31@gmail.com

TELEPHONE NO. : 03-5511 4086

FAX. NO. : 03-5511 4087

COMPANY REG. NO. : 869311-P

COMPANY STATUS : 100% BUMIPUTERA

DATE OF INCORPORATION : 24 OCTOBER 2003

JBE REG. NO. : (TKL)KE/869311P/2014

KEMENTERIAN KEWANGAN : K22108305431032022 (357-02185703)

BANK : MALAYAN BANKING BERHAD


9 & 11, JALAN ANGGERIK VANILLA N31/N,
KOTA KEMUNING, 40460 SHAH ALAM,
SELANGOR DARUL EHSAN

ACCOUNT NO. : 562786013725

PAID-UP CAPITAL : RM 750,000.00

AUTHORISED CAPITAL : RM 1,000,000.00

COMPANY SECRETARY : NCY MANAGEMENT SERVICES


ROOM 1.01, 31-1, LORONG BATU NILAM 3A,
BANDAR BUKIT TINGGI,
41200 KLANG, SELANGOR DARUL EHSAN.

COMPANY ADVISOR : AKAR MANAGEMENT


TINGKAT 1, KOMPLEKS PKNS,
40000 SHAH ALAM, SELANGOR DARUL EHSAN.
KEJURUTERAAN ELEKTRIK DELTA SAUJANA SDN. BHD.

(869311-P)
EXECUTIVE SUMMARY

EXECUTIVE SUMMARY

Kejuruteraan Elektrik Delta Saujana Sdn. Bhd. is a switchboard


manufacturer and electrical works company and also partnership to
many projects with highly establish corporation. Kejuruteraan Elektrik
Delta Saujana Sdn. Bhd. has been operating since October 2003 and
fully 100% Bumiputera company. Owner of the company is Encik
Mohammad Isa Jasa bin Abdullah and Puan Roslinda binti Mohd.
Abdul.

Kejuruteraan Elektrik Delta Saujana Sdn. Bhd. officially shifted to own


premises on March 2013 located at Lot 19, Jalan Pahat 16/8A,
Seksyen 16, 40200 Shah Alam, Selangor Darul Ehsan. Size of the
factory is 22 thousand square feet. We are one of the existing TM
Power Cabinet supplier and completed the contract in 2 years (2011 -
2012) with excellent record with TM Berhad.

Kejuruteraan Elektrik Delta Saujana Sdn. Bhd. accumulate vast


experiences in the past portfolios as electrical switchboard
manufactures and installer with Government Agencies, Government
Link Companies, Private Sectors and Overseas Ventures. Therefore we
became the most trusted name/ brand among our customers. Our
capacity and specialty products range are listed from small electrical
box Feeder Pillar to complicated High Tension Panel (HT).

Please do not hesitate to call our office at number of Tel No. : 03-5511
4086 Fax No. : 03-5511 4087 for more further verification.
MANAGING DIRECTOR
MOHD. ISA JASA BIN ABDULLAH
(869311-P)

STOREKEEPER FINANCE DIRECTOR


ENGINEERING DEPARTMENT
MOHAMAD AMIN BIN ROSLINDA BINTI MOHD.
MOHD SAKRI ABDUL

PROJECT MANAGER MECH. & ELEC. DESIGN SALES &


AHMAD ZAMIR BIN MOHD. ISA JASA BIN MARKETING
MOHAMED NOOR ABDULLAH MANAGER ACCOUNT
VACANCY EXECUTIVE / HR
ROHILI BT KASIM
ENGINEERING DEPT. DRAFTING (CAD)
VACANCY ROSLAINI BT. ATAN
PURCHASING DEPARTMENT
NOOR HAFIZAH BT ZAKARIA
INTAN NAJWA BT YUSLI

DRAFTER (CAD) TECHNICAL TEAM WIRING TEAM LEADER


ACCOUNT
INTAN NAJWA BT YUSLI LEADER ELANGO A/L MUNIAN
PROJECT
CHEY KAY MENG MUHAMMAD SYUKRI BIN
NOOR HAFIZAH BT
JAMALUDDIN
ZAKARIA
MUHAMMAD AMSSAM B.
ZULKEFLI
ORGANIZATION CHART

SWITCHBOARD
MECHANICAL TEAM
SWITCHBOARD
ELECTRICAL
TEAM
KEJURUTERAAN ELEKTRIK DELTA SAUJANA SDN. BHD.
KEJURUTERAAN ELEKTRIK DELTA SAUJANA SDN. BHD.

(869311-P)
CUSTOM LETTER ( ST )
KEJURUTERAAN ELEKTRIK DELTA SAUJANA SDN. BHD.

(869311-P)
ISO 9001:2015
KEJURUTERAAN ELEKTRIK DELTA SAUJANA SDN. BHD.

(869311-P)
SURUHANJAYA SYARIKAT MALAYSIA
KEJURUTERAAN ELEKTRIK DELTA SAUJANA SDN. BHD.

(869311-P)
KEMENTERIAN KEWANGAN MALAYSIA
KEJURUTERAAN ELEKTRIK DELTA SAUJANA SDN. BHD.

(869311-P)
KEMENTERIAN KEWANGAN MALAYSIA
KEJURUTERAAN ELEKTRIK DELTA SAUJANA SDN. BHD.

(869311-P)
KEMENTERIAN KEWANGAN MALAYSIA
KEJURUTERAAN ELEKTRIK DELTA SAUJANA SDN. BHD.

(869311-P)
SURUHANJAYA TENAGA
KEJURUTERAAN ELEKTRIK DELTA SAUJANA SDN. BHD.

(869311-P)
SURUHANJAYA TENAGA –
KONTRAKTOR ELEKTRIK
KEJURUTERAAN ELEKTRIK DELTA SAUJANA SDN. BHD.

(869311-P)
PERAKUAN PENDAFTARAN CIDB
KEJURUTERAAN ELEKTRIK DELTA SAUJANA SDN. BHD.

(869311-P)
LESEN MAJLIS TEMPATAN
KEJURUTERAAN ELEKTRIK DELTA SAUJANA SDN. BHD.

(869311-P)
SIRIM IP54 COMPLIANCE
KEJURUTERAAN ELEKTRIK DELTA SAUJANA SDN. BHD.

(869311-P)
SIRIM IP54 COMPLIANCE
KEJURUTERAAN ELEKTRIK DELTA SAUJANA SDN. BHD.

(869311-P)
SIRIM IP55 COMPLIANCE
KEJURUTERAAN ELEKTRIK DELTA SAUJANA SDN. BHD.

(869311-P)
SIRIM IP55 COMPLIANCE
KEJURUTERAAN ELEKTRIK DELTA SAUJANA SDN. BHD.

(869311-P)
PERAKUAN KEKOMPETENAN
SEBAGAI PENJAGA JENTERA
KEJURUTERAAN ELEKTRIK DELTA SAUJANA SDN. BHD.

(869311-P)
PERAKUAN KEKOMPETENAN
SEBAGAI PENJAGA JENTERA
KEJURUTERAAN ELEKTRIK DELTA SAUJANA SDN. BHD.

(869311-P)
PERAKUAN KEKOMPETENAN
SEBAGAI PENDAWAI
KEJURUTERAAN ELEKTRIK DELTA SAUJANA SDN. BHD.

(869311-P)

SELECTION CRITERIA
COMMERCIAL

• ACCURACY OF QUOTATION

• QUANTITIES

• PAYMENT TERMS

• PRICING (LOWEST, CONSISTENT,


COMPARABLE TO BUDGET
ALLOCATION)

• TOTAL PACKAGE or SPLIT ORDER


KEJURUTERAAN ELEKTRIK DELTA SAUJANA SDN. BHD.

(869311-P)

COMPANY PRODUCTS

COLD ROOM CONTROL


PANEL - KOLAM TERNAK
UDANG (JAKARTA)

MSB C/W SYNCHRONIZING -


TM EXCHANGE BATU

KUANTAN COMPRESSOR STATION


KEJURUTERAAN ELEKTRIK DELTA SAUJANA SDN. BHD.

(869311-P)

COMPANY PRODUCTS

Project Palm Oil Mill (8000Amp) – Myanmar


KEJURUTERAAN ELEKTRIK DELTA SAUJANA SDN. BHD.

(869311-P)

COMPANY PRODUCTS

TELEKOM MALAYSIA BERHAD


HSBB PROJECT

SYNCHRONIZING PANEL
LYNAS PROJECT
KEJURUTERAAN ELEKTRIK DELTA SAUJANA SDN. BHD.

(869311-P)

COMPANY PRODUCTS
500KW
GENERATOR
SYNCHRONISING
CONTROL PANEL
LAEM CHABANG,
THAILAND

500KW
GENERATOR
SNCHRONISING
CONTROL
PANEL
BAKUN
PROJECT
KEJURUTERAAN ELEKTRIK DELTA SAUJANA SDN. BHD.

(869311-P)

COMPANY PRODUCTS

SUB SWITCHBOARD
FOR IBM DATA CENTRE
KEJURUTERAAN ELEKTRIK DELTA SAUJANA SDN. BHD.

(869311-P)

COMPANY PRODUCTS

400A STARTER CONTROL PANEL


FOR WATER TREATMENT PLANT
DACCA DYEING, BANGLADESH
KEJURUTERAAN ELEKTRIK DELTA SAUJANA SDN. BHD.

(869311-P)

COMPANY PRODUCTS
PROJECT
TAMACO PALM OIL MILL

MAIN CONTROL PANEL


&
MOTOR CONTROL PANEL
KEJURUTERAAN ELEKTRIK DELTA SAUJANA SDN. BHD.

(869311-P)

COMPANY PRODUCTS

1600A MAIN SWITCHBOARD


IBUSAWAT TM BUKIT TIMBALAN,
JBU3, JOHOR BAHARU.
KEJURUTERAAN ELEKTRIK DELTA SAUJANA SDN. BHD.

(869311-P)

COMPANY PRODUCTS

2500A MAIN SWITCHBOARD


MOTOR CONTROL CENTER
FOR PT HENRISON, INDONESIA
KEJURUTERAAN ELEKTRIK DELTA SAUJANA SDN. BHD.

(869311-P)

COMPANY PRODUCTS

SYNCHRONISING PANEL,
MAIN SWITCHBOARD,
CAPACITOR BANK
FOR IKBN DUSUN TUA
KEJURUTERAAN ELEKTRIK DELTA SAUJANA SDN. BHD.

(869311-P)

COMPANY PRODUCTS

1200KVAR INDUCTIVE
LOAD BANK (P.F 0.8)
USE FOR GENERATOR
LOAD TESTING
KEJURUTERAAN ELEKTRIK DELTA SAUJANA SDN. BHD.

(869311-P)

TYPE TEST

 CARRIED OUT BY QUALIFIED


CHARGEMAN

 OUTDOOR IP55 SIRIM

 VERIFICATION THAT A PRODUCT


IS DESIGNED AND BUILT TO THE
REQUIREMENTS OF A
PARTICULAR STANDARD - NOT A
QUALITY ENDORSEMENT
KEJURUTERAAN ELEKTRIK DELTA SAUJANA SDN. BHD.

(869311-P)

CUSTOMER REFERENCE 2017


Item Project Name Customer Year Contract
Value
1 CELCOM – AUTORESET PANEL DELTA JITU 2017 RM 150,000.00

2 ELECTRICAL CONTROL CLICKS NETWORKS SDN BHD 2017 RM 687,000.00


SWITCHBOARD AMF BOARD

3 SWITCHBOARD AND ELECTRICAL FOOD NETWORKS SDN BHD 2017 RM 624,000.00


WORKS

4 INDUCTIVE LOAD BANK 500KVAR VPM POWER SDN BHD 2017 RM 92,538.00

5 SUPPLY DB FOR PROJECT MRT SG APEX 2017 RM 240,000.00


BULOH

6 SUPPLY, INSTALL & COMISSIONING UTAMAS TEKNIK SDN BHD 2017 RM 15,100.00
1 LOT NIKEL CADMIUM BATTERY
FOR SIRIM BERHAD

7 SUPPLY, INSTALL AND D’JAGAL SDN BHD 2017 RM 347,000.00


COMMISSIONING 2000AMPS MSB
FOR LAPANGAN TERBANG SUBANG

8 EMERGENCY WORKS - TELEKOM MALAYSIA BERHAD 2017 RM 52,947.00


REPLACEMENT ATS 1200A AND ACB
1250A DI SKDL MERSING, JOHOR

9 SUPPLY DB’S AND AIR COND PANEL SYAUQI ENTERPRISE 2017 RM 145,000.00
FOR TM PROJECT

11 PROVISION OF GENSET TELEKOM MALAYSIA BERHAD 2017 RM 430,000.00


SYNCHRONISING SYSTEM FOR
GUNUNG AMPANGAN SERIAN,
SARAWAK
12 SUPPLY & INSTALL 6 X 200KVA K13 TELEKOM MALAYSIA BERHAD 2017 RM 486,382.00
ISOLATION TRANSFORMER FOR
BACKHAUL RECTIFIER AT JOHOR
ISKANDAR
13 SUPPLY & INSTALL MAIN TELEKOM MALAYSIA BERHAD 2017 RM 136,934.00
SWITCHBOARD AND OTHERS
RELATED WORKS AT TM SEREMBAN
2 AND SG BARU MELAKA
KEJURUTERAAN ELEKTRIK DELTA SAUJANA SDN. BHD.

(869311-P)

CUSTOMER REFERENCE 2017


Item Project Name Customer Year Contract
Value
1 SUPPLY 200KW LOAD BANK SINCRO POWER SDN BHD 2017 RM 39,008.00

2 REPLACEMENT OF 415V MCC PANEL PNSB WATER SDN BHD 2017 RM 170,600.00
NO 1 & CABLING WORKS FOR
PUMPING STATION AT SG RANGKAP
& SG BATU WTP
3 REPLACEMENT OF MAIN TELEKOM MALAYSIA BERHAD 2017 RM 535,000.00
SWITCHBOARD AT EXCHANGE TM
PEKAN NENAS, FELDA WA HA, SG
RENGIT, PARIT BAKAR, BUKIT
PASIR, KG BARU LENGAN AND
BULOH KASAP
4 PROJECT : HOSPITAL PORT DICKSON VPM POWER SDN BHD 2018 RM 162,000.00
& KULAI , 2 x 400KVA AUTO SYN.
CONTROL PANEL c/w BY-PASS
SYSTEM.
KEJURUTERAAN ELEKTRIK DELTA SAUJANA SDN. BHD.

(869311-P)

LIST OF PROJECT - 2018


Item Project Name Customer Year Contract
Value
1 MAIN DISTRIBUTION BOARD C&P BUILDER SDN BHD 2018 RM 1 MILLION
( PROJECT : CONSTRUCTION NEW ( 2016 – 2017 )
FACTORY FOR RAMLY FOOD )

2 SYNCHRONIZING CONTROL PANEL SINCRO POWER SDN BHD 2018 RM 182,300.00


AND NO BREAK CHANGEOVER
SYSTEM FOR AGENSI
PENGUATKUASAAN MARITIM
MALAYSIA
3 CONTROL PANELS FOR RAMLY NRS PROCESS SYSTEMS SDN 2018 RM 204,000.00
FOOD PRCESSING , PULAU INDAH BHD

4 SUPLLY AND INSTALL 400A AMF MAHKOTA TECHNOLOGIES SDN 2018 RM 13,600.00
BOARD C/W 400A AUTOMATIC BHD
CHANGEOVER PANEL ( FLOOR
STANDING TYPE )

5 SUPPLY AND INSTALL MAIN ZAMODA SDN BHD 2018 RM 891,162.00


SWITCHBOARD C/W
SYNCHRONIZING FACILITY MANUAL
& AUTO FOR INSTITUT KEMAHIRAN
MARA KOTA KINABALU, LUMUT, SG.
PETANI & JASIN, MELAKA
6 SUPPLY, INSTALL & D’JAGAL SDN BHD 2018 RM 122,960.00
COMMISSIONING 600AMPS 6 WAY
FLOOR STANDING SSB FOR TM
KELANG SELATAN & TM PUTRAJAYA

7 SUPPLY CONTROL PANEL FOR UNIVERSAL ENVIRONMENT 2018 RM 27,700.00


SEWAGE TREATMENT PLANT (STP) ENG SDN BHD
FOR KSEW

8 SUPPLY MSB AND TNB METAL PAGUT ELECTRICAL 2018 RM 59,042.00


KIOSK PANEL FOR STADIUM IPOH, CONTRACTOR
PERAK
KEJURUTERAAN ELEKTRIK DELTA SAUJANA SDN. BHD.

(869311-P)

LIST OF PROJECT - 2019


Item Project Name Customer Year Contract
Value
1 PROVISION FOR REPLACING 1 UNIT TRACTOR PETROLEUM 2019 RM 289,093.00
1500KW, 415VAC, 50HZ RESISTIVE SERVICES SDN BHD
LOAD BANK INCLUSIVE OF
STRUCTURE, ENGINEERING
DRAWING, DATA SHEET, O&M, FAT,
INSTALL & COMMISSIONING
2 PROVISION FOR PERFORM TRACTORS PETROLUEM 2019 RM 310,835.00
ENGINEERING, PROCUREMENT, SERVICES SDN BHD
INSTALLATION AND
COMMISSIONING ACTIVITIES FOR
EDG CONTROL PANEL PLC UPGRADE
AT SUBSTATION UTILITIES GEBENG
3 CP-P MAIN PANEL, ELECTRICAL FOR DIVERSE PRODUCT 2019 RM 100,674.00
OGPC SKID DISPENSER ENGINEERING SDN BHD

4 SUPPLY DISTRIBUTION BOARD FOR C & P BUILDER SDN BHD 2019 RM 269,800.00
PROJECT RAMLY FOOD AT PULAU
INDAH

5 SEWAGE SUMP PUMP AT TAMAN RIGHTWAY WATERWORKS 2019 RM 72,105.00


PD UTAMA (PDN 017) 400V PUMP SDN BHD
STARTER BOARD AND
SEWAGE SUMP PUMP AT TAMAN
INTAN DUYUNG (PDN 112) 400V
PUMP STARTER BOARD
6 KERJA KECEMASAN MENGGANTI TELEKOM MAYALSIA BERHAD 2019 RM 28,130.00
ATS DI KLUANG

7 REPLACEMENT MSB BOARD AND TELEKOM MALAYSIA BERHAD 2019 RM 224,000.00


AIR CURCUIT BREAKER (ACB) FOR
TELEKOM SITE TELOK GONG
8 CADANGAN PEMBANGUNAN ACSO GLOBAL (M) SDN BHD 2019 RM 14,740.00
PERSAHABATAN TAMAN
PERSAHABATAN SELANGOR JEPUN
DI SEBAHAGIAN TASIK TIMUR
(BERHAMPIRAN KEDAI KOPI 2)
TAMAN TASIK SHAH ALAM UNTUK
MAJLIS BANDARAYA SHAH ALAM.
9 KERJA-KERJA PENUKARAN PAPAN TELEKOM MALAYSIA BERHAD 2019 RM 73,000.00
SUIS UTAMA DAN KERJA-KERJA
BERKAIATAN DI IBUSAWAT TM
SAGIL, JOHOR
KEJURUTERAAN ELEKTRIK DELTA SAUJANA SDN. BHD.

(869311-P)

LOCATION MAP

KEJURUTERAAN ELEKTRIK DELTA SAUJANA SDN. BHD.


LOT 19, JALAN PAHAT 16/8A, SEKSYEN 16,
40200 SHAH ALAM, SELANGOR DARUL EHSAN.
Email : desana31@gmail.com
Tel : 03-5511 4086 Fax : 03-5511 4087
Manufacturer Certificate
Material List

AU TO M AT I C T R A N S FE R S W I TC H E S

Compact ATS
Compact without compromise

• Safety and protection


• Space Saving
• Affordable range
2 A B B C O M PA C T AT S C O M PA C T W I T H O U T C O M P R O M I S E

-—
ABB Compact ATS
Compact without compromise
The new Compact ATS by ABB is just that – It’s a compact, economical and
innovative all-in-one solution that delivers all the safety and performance
you would expect from a product supplying your most valuable assets. An
automatic transfer switch does not need to be complex and difficult to use.
Compared to conventional solutions, the ABB Compact ATS offers 100%
easier and simpler operation in a 40% more compact package.

The Compact ATS is an ideal device for securing


the availability of stand-by power in a wide
variety of residential, commercial, industrial and
agricultural structures. The IEC 60947-6-1 tested
devices fulfil the requirements of Part 6-1, making
them multiple function apparatus. ABB Compact
ATS is a safe and approved solution for any
application where a reliable and complete source
transfer device is required.

Typical end use applications:


ABB Compact ATS devices work best when
providing an alternative power source for any
HVAC machinery. Here are just a few of the most
typical locations where they are used:
• Residential, commercial and industrial facilities
• Telecommunication and data centres
• Agricultural applications
• And more…
A B B C O M PA C T AT S C O M PA C T W I T H O U T C O M P R O M I S E 3


ABB Compact ATS
Compact without compromise

Watch the videos to learn more:

Safety and protection


Operation and functionality
All current-carrying parts of the device are fully
Learn how to operate Compact
enclosed without exposed wiring, providing
ATS manually and automatically
protection against direct contact. In case of an
and how it works.
emergency or testing event, an external, easily
accessible manual handle provides a safe and
easy (electrical or non-electrical) source transfer.

Range and installation of


accessories
Get to know the ATS offering
and how easy it is to install the
needed accessories.
Space saving
The device has been designed to be extremely
compact and fully enclosed. Compared to a
conventional solution, the Compact ATS takes up
approximately 40% less cabinet space. The all-in-
one design means that no additional accessories
are needed. You don’t even need an extra external
power source.

Affordable range
Affordability has been one of the key objectives
for this device. The available functionalities have
been carefully selected to meet market
requirements without added niche features that
would elevate price. It is simple, reliable and
functional.

Accurate communication
The in-built IO signals enable you to control your
system conveniently. The remote test signal
allows you to pre-test and maintain your ATS at
any time.
Modbus RTU communication is available for
Compact ATS adjustable versions. With Compact
ATS, you are ready for connectivity now and in the
future.
4 A B B C O M PA C T AT S C O M PA C T W I T H O U T C O M P R O M I S E
A B B C O M PA C T AT S C O M PA C T W I T H O U T C O M P R O M I S E 5


Ordering information
OTM_C_D products

OTM_C20D
For Network/Network application

Fixed version with pre-defined delay times and


voltage thresholds


Fixed version

Number of poles Rated current [A] Rated voltage [V] Voltage sensing Type Ordering code Weight [kg]
2 63 230-220-240 Top in OTM63F2C20D230C 1SCA151421R1001 1.75
2 125 230-220-240 Top in OTM125F2C20D230C 1SCA151417R1001 1.75
3 63 380-400-415 Top in OTM63F3C20D400C 1SCA151423R1001 1.75
3 125 380-400-415 Top in OTM125F3C20D400C 1SCA151419R1001 1.75
4 40 380-400-415 Top in OTM40F4C20D400C 1SCA151252R1001 2.00
4 63 380-400-415 Top in OTM63F4C20D400C 1SCA151254R1001 2.00
4 125 380-400-415 Top in OTM125F4C20D400C 1SCA151250R1001 2.00

OTM_C21D
For Network/Network and Network/Genset applica-
tions

Adjustable version with configurable transfer and


back-switching delays
Adjustable over and under-voltage thresholds

Modbus RTU access available with plug-in Modbus


RTU module. See accessories section, page 10.



Adjustable version

Number of poles Rated current [A] Rated voltage [V] Voltage sensing Type Ordering code Weight [kg]
2 63 230-220-240 Top in OTM63F2C21D230C 1SCA151422R1001 1.75
2 125 230-220-240 Top in OTM125F2C21D230C 1SCA151418R1001 1.75
3 63 380-400-415 Top in OTM63F3C21D400C 1SCA151424R1001 1.75
3 125 380-400-415 Top in OTM125F3C21D400C 1SCA151420R1001 1.75
4 40 380-400-415 Top in OTM40F4C21D400C 1SCA151253R1001 2.00
4 63 380-400-415 Top in OTM63F4C21D400C 1SCA151255R1001 2.00
4 125 380-400-415 Top in OTM125F4C21D400C 1SCA151251R1001 2.00
4 40 380-400-415 Bottom in OTM40F4CB21D400C 1SCA150580R1001 2.00
4 63 380-400-415 Bottom in OTM63F4CB21D400C 1SCA150586R1001 2.00
4 125 380-400-415 Bottom in OTM125F4CB21D400C 1SCA150574R1001 2.00
6 A B B C O M PA C T AT S C O M PA C T W I T H O U T C O M P R O M I S E


Technical features and functionality
Compact ATS

OTM_C20D_ OTM_C21D_
OTM_C_D products overview Fixed version Adjustable version
Features
Single phase (2 poles) 220~240+/-20% 220~240+/-20%
Rated operational voltage Ue Three phase (3 and 4 poles) 380~415+/-20% 380~415+/-20%
Rated frequency 50 / 60 Hz +/- 10%
Voltage sensing precision 5% 3%
Rated impulse withstand voltage, Uimp 6 kV
Overvoltage category III
Pollution degree 3
Protection rating for the front panel IP20
Operating temperature – 20...+ 55 °C
Transportation and storage temperature – 25...+ 70 °C
Altitude Max. 2000m
Humidity With condensation 50% at 40 °C, 90% at 20°C
Humidity Without condensation 50% at 40 °C, 90% at 20°C

Operation Types
Manual operation with handle x x
Local operation with front panel keypad x
Automatic transfer switching equipment (ATSE) x x
Applications
Transfer between two Transformers x x
Transfer between a Transformers and a generator x
Operation modes
Automatic transfer and back-switching operation x x
Automatic transfer and manual back-switching operation x
Source failure detections
No voltage x x
Undervoltage 0.7-0.95 Ue
Overvoltage 1.05-1.3 Ue
Phase missing x x
Voltage unbalance
Invalid frequency
Configuration
By DIP switches x x
By rotary switches x
Two power status display x x
Two switches status display x x
Auto status display x x
Alarm display x x
A B B C O M PA C T AT S C O M PA C T W I T H O U T C O M P R O M I S E 7


Technical features and functionality
Compact ATS

OTM_C_D products overview OTM_C20D_ OTM_C21D_


Time delays
Delay on transfer 1) 0-30s
Back-switching delay 0-900s
Generator stop delay 240s
Signals input and output
Emergency Off with 24VDC signal input x x
Test signal input x

Switch position signal With Auxiliary contacts Without Auxiliary contact


Alarm output signal x
Modbus RTU access2) x
1)
Overvoltage and undervoltage conditions
2)
With Modbus RTU plug-in module


Compact ATS
Easy use and installation

— —
01 Easy manual operation with the 02 DIN- rail mounting
handle in case of emergency


03 Base mounting with screws
8 A B B C O M PA C T AT S C O M PA C T W I T H O U T C O M P R O M I S E


Technical data
Compact automatic transfer switches OTM40...125_


Compact automatic transfer switches
Switch size
Data according to IEC 60947-3 OTM40_ OTM63_ OTM125_
Rated insulation voltage and rated Pollution
operational voltage AC20/DC20 degree 3 V 750 750 750
Dielectric strength 50 Hz 1min. kV 6 6 6
Rated impulse withstand voltage kV 8 8 8
Rated thermal current and rated / ambient 40°C In open air A 40 63 125
operational current AC20/DC20
/ ambient 40°C In enclosure A 40 63 125
/ ambient 60°C In enclosure A 32 50 100
..with minimum conductor cross section Cu mm2 10 16 50
Rated operational current, AC-21A up to 500 V A 40 63 125
690 V A 40 63 125
Rated operational current, AC-22A up to 500 V A 40 63 125
690 V A 40 63 125
Rated operational current, AC-23A up to 415 V A 40 63 90
500 V A 40 60 70
690 V A 40 40 50
Rated operational current / poles in series, DC-21A up to 48 V A 40/1 63/1 125/1
110 V A 40/2 63/2 125/2
220 V A 40/4 63/4 125/4
Rated operational current / poles in series, DC-22A up to 48 V A 40/1 63/1 125/1
110 V A 40/2 63/2 125/2
220 V A 40/4 63/4 80/4
Rated operational current / poles in series, DC-23A up to 48 V A 40/1 63/1 125/1
110 V A 40/2 63/2 125/2
220 V A 40/4 63/4 63/4
Rated operational power, AC-23A1) 230 V kW 7.5 15 22
The kW-ratings are accurate for 3-phase 400 V kW 18.5 30 45
1500 R.P.M. standard asychronous motors
415 V kW 18.5 30 45
500 V kW 22 37 45
690 V kW 37 37 45
Rated breaking capacity in category AC-23 up to 415 V A 320 504 720
500 V A 320 480 560
690 V A 320 320 400
Rated conditional short-circuit current Ip Ip (r.m.s.) 50 kA, 415 V îc (peak) kA 16.5 16.5 16.5
(r.m.s.) and corresponding max. allowed
Max. OFA_ fuse size gG/aM A/A 125/125 125/125 125/125
cut-off current îc (peak) value.
Ip (r.m.s.) 18 kA, 690 V îc (peak) kA 11 11 11
The cut-off current îc refers to values Max. OFA_ fuse size gG A 125 125 125
listed by fuse manufacturers (single
phase test acc. to IEC60269). Ip (r.m.s.) 50 kA, 690 V îc (peak) kA 10 10 10
Max. OFA_ fuse size gG/aM A/A 63/63 63/63 63/63
Rated short-time withstand current Icw (r.m.s.) 690 V 1s kA 2.5 2.5 2.5
Rated short-time making capacity2) Icm (peak) 690 V kA 3.6 3.6 3.6
Power loss / pole With rated current W 1.6 2.8 6.3
Mechanical endurance Number of oper. cycles3) Cycles 10 000 10 000 10 000
Cable size Cu-wire size suitable for mm2 10-70 10-70 10-70
terminal clamps
AWG 8-00 8-00 8-00
Terminal tightening torque Counter torque required Nm 6 6 6

Typical for 3-pole


Operating torque switches Nm 5 5 5
Weight without accessories 3-pole switch kg 1.75 1.75 1.75
4-pole switch kg 2.00 2.00 2.00
A B B C O M PA C T AT S C O M PA C T W I T H O U T C O M P R O M I S E 9


Technical data
Compact automatic transfer switches OTM40...125_


Compact automatic transfer switches
Switch size
Data according to IEC 60947-6-1 OTM40_ OTM63_ OTM125_
Class of equipment PC PC PC
Rated short-time withstand current Icw (r.m.s.) 690 V 0.1s kA 5 5 5
Conditional short-circuit current Icc (r.m.s.) 415 V kA 50 50 50
Corresponding fuse rating gG/aM fuse 415 V A 125 125 125
Rated operational current, AC-31B up to 415 V A 40 63 125
Rated operational current, AC-32B up to 415 V A 40 63 125
Rated operational current, AC-33B up to 415 V A 40 63 80

1)
These values are given for guidance and may vary according to the motor manufacturer
2)
Short circuit duration > 50ms, without fuse protection
3)
Operating cycle: O - I - O - II - O


Compact ATS
Dimensional drawings
10 A B B C O M PA C T AT S C O M PA C T W I T H O U T C O M P R O M I S E


Ordering information
Accessories

Handles, direct mounting


Plastic I - O - II handle.

Suitable for Installation Units/type Weight/


Colour Type Order number
switches side [pcs] unit [kg]

OTM40…125F_CM Black Shaft incl. OHB65D6CM 1SCA022807R9430 1 0.12


OTVS0

Handle storage clip


The handle can be stored in the handle storage clip OTVS0. The handle storage clip can be
fixed to a panel frame using the included adhesive tape.

Suitable for Units/type Weight/


Type Order number
switches [pcs] unit [kg]

OTM40…125F_CM OTVS0 1SCA117524R1001 1 0.02

OA1G01
OA7G10
Auxiliary contacts
Snap-on mounting to the switch, IP 20, max. 2 blocks/ side. Ith = 16 A, suitable for cable cross
sections max. 2 x 2.5 mm2. Simultaneous action with the main contacts. The type and order-
ing number is for one piece.

Suitable for Contact Installation Units/type Weight/


Type Order number
switches function side [pcs] unit [kg]

OTM40...125F_CM 1NO Right OA1G10 1SCA022353R4970 1 0.03


OTM40...125F_CM 1NC Right OA8G01 1SCA022744R2240 1 0.03
OA1G10
OA8G01 OTM40...125F_CM 1NO Left OA7G10 1SCA022673R1140 1 0.03
OTM40...125F_CM 1NC Left OA1G01 1SCA022353R4890 1 0.03

Modbus RTU module


The plug-in module can be mounted on top of 21D/adjustable versions of Compact ATS

Suitable for Units/type Weight/


Description Type Order number
RTU module switches [pcs] unit [kg]

OTM40...125F_CM (21D) OTM RTU MODULE 2TFC800169R1001 1SCA161952R1001 1 0.03

Mounting of Modbus RTU


module
A B B C O M PA C T AT S C O M PA C T W I T H O U T C O M P R O M I S E 11


Ordering information
Accessories

Terminal shrouds
Transparent plastic, snap-on mounting to the switches, IP20. The full shrouding of a 3-pole
change-over switch is achieved with four 3-pole shrouds.*

OTS_T3 Suitable for Units/type Weight/


Type Order number
switches [pcs] unit [kg]

For three pole switches


OTM40...125F_CM OTS125T3 1SCA022379R9680 1 0.03
For fourth pole
OTPS60FP, OTPS125FP OTS125T1 1SCA022379R9760 1 0.03

Terminal clamp sets


OTS_T1
Suitable for Contact Units/type Weight/
Type Order number
switches function [pcs] unit [kg]

Terminal clamp sets for Al- and Cu-cables insulated versions


OTM40...125F_CM 16...50 Al / 2.5...50 Cu OZXT1 1SCA022469R6310 3 0.06
OTM63...125F_CM 16...120 Al/Cu OZXT2 1SCA022620R7200 3 0.21
OTM63...125F_CM 2x(16...50) Al/Cu OZXT3 1SCA022639R0720 3 0.21
Including 0.75...2.5 mm2 voltage sensing connection. Voltage sensing wires are not included in the delivery
OTM40...125F_CM 16...50 Al/2.5...50 Cu OZXT6 1SCA122537R1001 3 0.06
Terminal clamp sets for Al- and Cu-cables
OZXT1
OTM40...125F_CM 10...70 Al/Cu OZXL1 1SCA022439R6770 3 0.14

Parallel connection kits


Finger protected connection bars for parallel connection of the upper or lower terminals.
The bars accept additional cables, the maximum size is stated below.

Suitable for Cable crosssection Units/type Weight/


Type Order number
switches [mm2] [pcs] unit [kg]
OZXT2...3
OTM40F3CM_ 2.5...25/2x2.5...16 OMZC003 1SCA121324R1001 1 0.5
OTM40F4CM_ 2.5...25/2x2.5...16 OMZC004 1SCA121325R1001 1 0.65
OTM40…125F3CM_ 10...70 OMZC03 1SCA117037R1001 1 0.5
OTM40…125F4CM_ 10...70 OMZC04 1SCA117038R1001 1 0.65

* Terminal shrouds can also be mounted on parallel connection kits.

OZXT6

OMZC_

ABB Electrification

www.abb.com

Find the address of your local sales


organization on the ABB homepage:

www.abb.com/contacts
> Low Voltage Products and Systems

1SCC308001B0201 21-11

© Copyright 2021 ABB. All rights reserved.


Specifications subject to change without notice.
Protection Features

AGR-11B AGR-21B AGR-31B

Protection Functions Protection Functions Protection Functions


Dial Adjustment LCD Ammeter Back-Lit Energy Analyser
L – Long Time L – Long Time L – Long Time
S – Short Time S – Short Time S – Short Time
I – Instantaneous I – Instantaneous I – Instantaneous
Pre-Trip (load shedding) Pre-Trip (load shedding)
Fault Indication Contacts Fault Indication Contacts
Optional Protection Functions
Unrestricted Ground Fault Optional Protection Functions Optional Protection Functions
Neutral Protection Ground Fault (Unrestricted or Restricted) Ground Fault (Unrestricted or Restricted)
Neutral Protection Neutral Protection
Communication Reverse Power
Manual Reset Phase Rotation Protection Zone Interlocking
(Optional - AGR-11BL-AS
Generator Protection Curves 3C Overheating Protection
AGR-11BL-GS) IDMT Protection Curves Communication
Field Test Phase Rotation Protection
Generator Protection Curves
IDMT Protection Curves
Field Test
Under/over Frequency
Under/over Voltage Alarm
NEW Harmonic Monitoring
Event history
Dual settings capability

Non-Automatic (switch-disconnector) versions without protection are available in every frame size.

12 | TemPower 2 Air Circuit Breakers


Protection Features

Overload Protection Reverse power trip function (S-characteristic)


Adjustable from 40-100% of rated current. Thermal memory is This feature provides additional protection when paralleling
available on the AGR21B.31B. generators. The AGR22B/31B protection relay for generator
protection with the reverse power trip function , negates the need
for installation and wiring in an external reverse power relay. This
1
feature is available using an AGR protection relay with a generator
Two channel pre-trip alarm function (optional)
“S” type characteristic only. (ANSI-32R)
This function can be used to monitor critical circuits. For
example, the function can be set so that when a pre-trip alarm is Advanced LCD display, Protection Relay
activated, non-essential loads can be switched off. This feature
The AGR-31B protection relay comes standard with the backlit
is only available on AGR22B/31B protection relay models with a LCD display. It can monitor and indicate phase currents, voltages,
generator “S” characteristic. power, energy, power factor, frequency and more. For features
refer to page 40. The backlit LCD is optional for AGR-21B and
AGR-22B.
Negative Sequence Current Protection Function
In 3-phase, 4 wire systems that contain harmonic distortion, Remote Communications Protocols (optional)
large currents may flow through the neutral conductor. The
Data communications via Modbus, an open network, are
N-phase protection function prevents the neutral conductor
supported.
from sustaining damage or burn-out due to these large currents.
(ANSI-46). Energy Measurement
I, V, kW, MWh, kVar, cosø, frequency, harmonics
Intelligent Fault Analysis
Ground fault trip function Status, fault type, fault size, tripping time, fault history
This function eliminates external relays to provide a ground fault Maintenance Information
protection to TN-C or TN-S power distribution systems on the Trip circuit supervision, contact temperature monitoring.
load side. Ground fault protection on the line side (restricted For details please refer to page 14.
earth fault) is also available as an option. For other protocols please contact Terasaki.

3C Overheating Protection (optional)


Earth leakage trip function
This function monitors the temperature of the ACBs main
Used in conjunction with Zero phase Current Transformer (ZCT),
contacts. An alarm indicates when the temperature exceeds
this function provides protection against leakage to earth of very
the withstand temperature of the contacts. Continuous
small levels of current. Trip or alarm indication, and contact
monitoring of the contact temperature provides valuable input
output is available to enhance the level of system protection.
for preventative and predictive maintenance programmes. This
option can be used with communication.

Phase rotation protection function New Features (more details on page 3)


This function detects the negative-phase current occurring due to
Two independent INST thresholds for quick toggling of safe mode.
reverse phase or phase loss and prevents burnout of a motor or
damage to equipment. Fine adjustment of overload current LTD threshold to the nearest
Ampere.
Harmonic current measurement.
Under/over voltage protection (ANSI 27A/810) (optional).
Under/over frequency protection (ANSI 81U/59A)(optional).

Understanding and employing TemPower 2 special features | 13


Protection Features

Communications facility added to TemPower 2

1 Data Measurement
Phase current Phase current I1, I2, I3, IN, Ig and max current
TemPower 2 is equipped with an optional communication Imax are measured and transmitted.
interface unit that allows data exchange with a host PC via Harmonic currents.
a Modbus open network. Data communication includes Line-to-line voltage V12, V23, and V31 are measured.
measurements, fault log, maintenance information. ON/OFF Demand active power Active power demand (over time) and historical
max. power are recorded.
status, settings and control (ON/OFF/RESET) signals.
Accumulated power Accumulated power is measured.
Power factor Circuit power factor is measured.
Frequency Frequency is measured.
Fault log
Note: Above is for type AGR-31 Protection relay.
Cause Whichever trip functions, LTD, STD, INST Type AGR-21 and AGR-22 measure only phase current.
or GF is activated is then transmitted
Fault current The fault current at which the breaker
tripped open is transmitted. Network Interface I/O specifications
Trip pick-up time The trip pick-up time is transmitted. Item Modbus
Transmission standard RS-485
Transmission method Two-wire half-duplex
Maintenance Information Topology Multi-drop bus
Tripping circuit The tripping coil is always monitored for Transmission rate 19.2 kbps max
monitoring disconnection. If the breaker is not open Transmission distance 1.2 km max (at 19.2 kbps)
within approx. 300 ms of a trip signal
Data format Modbus-RTU or ASCII
delivered from the OCR, an alarm signal
is generated. Max number of nodes 1 - 31

On-screen PC monitor Communication network

Power Monitoring

Host PC
Next page

TR 3 ø750 kVA
Host network
6600/460V Print
Fault cause protection relay status Long time-delay
Short time-delay ACB No.1 ON
Instantaneous I1 729 A
Ground fault V12 455 V
Power factor 95 % Commercial gateway or PLC
Fault current A
Power 546 kW
ACB Tripping time sec. Electric energy 1041 kWh

RS485

ON ON ON OFF ON

320 A 206 A 180 A 0 A 23 A


418 KWh 364 KWh 235 KWh 13 KWh 11 KWh

Power supply No. 1 Power supply No. 2 Power supply No. 3 Pump Conveyer

Modbus
Up to 31 units can be
connected per system

14 | TemPower 2 Air Circuit Breakers


Protection Features

Optimum protective co-ordination

Why use a separate panel mounted protection relay when you


can have all the benefits of I.D.M.T. protection integral to the
ACB?
1
TemPower 2 is available with a choice of flexible protection
curves to assist in selectivity applications.

S.I. Standard Inverse


V.I. Very Inverse
E.I. Extremely Inverse

All these curves are user definable and comply with IEC 60255-3.
Standard transformer and generator protection characteristics are
also available.

AGR-L Industrial & transformer protection


AGR-S Generator protection
AGR-R Characteristics to IEC 60255-3
Inverse Definite Minimum Time (I.D.M.T.)

Zone interlocking

In conventional discrimination systems, short time delays are used


to allow a short-circuit current to be tripped by the circuit breaker
nearest the fault. The disadvantage of this type of system is during
ACB A
a fault considerable thermal and mechanical stresses are placed
on the entire system. With the TemPower 2 Z Interlock system the
breaker nearest the fault will trip first, irrespective of the short time
delay setting or ground fault trip time delay setting.

Example of operation: ACB B

ACB C

Understanding and employing TemPower 2 special features | 15


Performance Features

Double opening and closing coils

1
Double Opening and Closing coils provides extended
control system redundancy to an ACB. Double coils allow
designers to implement back-up tripping and closing
systems. It provides the end user with ultimate reliability
on critical UPS circuits connected to critical loads.

Earthing Device

The unique design of TemPower 2 ACBs allows for the


earthing of either the busbar (line) or the circuit (load) of a
low voltage system; thus allowing system flexibility.
Some other manufactures only offer one option either,
busbar or circuit earthing.
For full details refer to page 36.

Protection Relay performance

External
Relay

Ensure that the ACB you specify suffers no loss of


performance when tripped by an external protection relay. 100kA

The TemPower 2 ACB suffers no loss in performance


when tripped through an external protection relay.
Some competitor’s ACBs have reduced breaking “TemPower 2 ACB”
performance when an external protection relay is used. with internal or external
protection relay.

16 | TemPower 2 Air Circuit Breakers


ACB Accessory Overview

Position Switches 1

Interpole Barriers
Shunt Trip Coil Open / Close Counter

IP55 Transparent Cover

Auxiliary Switches

Capacitor Shunt Trip 48V DC

Lifting Plates IP3X Chassis Protection Cover


IP31 Door Flange

Double Opening/
Closing Coils

Fixing Bolts (For Draw Out ACBs)

Trip Indicator Switch


Spring Status Switch
Auto Spring
Discharge Device
Storage Draw Out Handle

Motor Operator OVERHEATING


PROTECTION

Lifter Loader Protection Relay Tropicalisation, Anti-Corrosion, Test Jumper Step Down Mechanical Interlock, Shutter
Checker Cold Climate treatments Transformer Key Interlock, Truck
440V to 220V Castell Interlock

Understanding and employing TemPower 2 special features | 17


TemPower 2 Air Circuit Breakers

APPEARANCE
1

18 | TemPower 2 Air Circuit Breakers


Ratings
Series
AMPERE RATING(A)
TYPE AR208S AR212S AR212H AR216S AR216H AR316H AR220S AR220H
RATED CURRENT (max) [ I n ](A) JIS , IEC, EN, AS
NEMA, ANSI
Marine
NEUTRAL POLE AMPERES FRAME (A)
NUMBER OF POLES
RATED PRIMARY CURRENT OF OVER–CURRENT
RELEASE [ I CT ](A)

RATED CURRENT OF OVER–CURRENT RELEASE(A) In In In In In In In 1000 I n 2000


In In In In In In
[I n In In In In In In
In In In In In

2 In In In In
1000 I n 2000
AC RATED INSULATION VOLTAGE [U i
RATED OPERATIONAL VOLTAGE [U e

JIS
[I =I

NK

LR, AB,

REVERSE CONNECTED
U ](kV)

CURRENT[ I

TOTAL BREAKING TIME (s)


CLOSING OPERATION TIME

OUTLINE DIMENSION (mm)


FIXED TYPE a
b b

a
TYPE b b

AGR protection relays cannot be used for DC. Please contact TERASAKI

Note:

20 | TemPower 2 Air Circuit Breakers


Ratings

AR320H AR420H AR325S AR325H AR332S AR332H AR440SB AR440S AR440H AR650S AR663S AR663H

1000 I n 2000 400 I n 800 1250 I n 2500 1250 I n 2500 1600 I n 3200 1600 I n 3200 2000 I n 4000 2000 I n 4000 2000 I n 4000 In In 2500 I n 5000
1000 I n 2000 3150 I n 6300


— — — — — — — — — — — —

— — — — — — — — — — — —
— — — — — — —
— — — — — — —
— — — — — — —

Choosing a TemPower 2 ACB | 21


Specifications

TemPower 2 series ACBs have an extensive range of accessories available, enabling the ACBs to be “custom built” to suit
every application.

22 | TemPower 2 Air Circuit Breakers


Specifications

1Types of of
Types Mounting
Mounting

Draw-out type Fixed type

This type of ACB consists of a breaker body and a draw-out This type of ACB has no draw-out cradle and is designed to be
cradle. The breaker body can be moved within or removed from directly mounted in the switchboard.
the draw-out cradle that is fixed in the switchboard.
Terminal arrangements
There are four breaker body positions: CONNECTED, TEST, Main Circuit terminals
ISOLATED and WITHDRAWN. The switchboard panel door can Three (3) types of main circuit terminal arrangements are available:
be kept closed in the CONNECTED, TEST and ISOLATED positions vertical terminals, horizontal terminals and front connections.
(“shut-in three positions). Different types of terminal arrangements can be specified for the

2
line and load sides.
Note: The max. rated current [In] may be reduced depending on the main circuit
CONNECTED position terminal arrangement. For more information see page 84.

Both the main and control circuits are connected for normal service.

TEST position

The main circuit is isolated and the control circuits are connected.
This position permits operation tests without the need for opening the
switchboard panel door.

ISOLATED position

Both the main and control circuits are isolated. The switchboard panel
door does not need to be opened.

WITHDRAWN position Control circuit terminals


Control circuit terminals are front located to allow easy wiring/access.
The terminal blocks (for auxiliary
switches, position switches and
control circuits) are positioned on
the top of the ACB front panel and
can be accessed from the front for
wiring.
The breaker body is fully withdrawn from the draw-out cradle.
M4 screw terminals are standard.

Choosing a TemPower 2 ACB | 23


Innovators in Protection Technology

TEMBREAK 2 MCCBs

SECTION 1
WELCOME TO TEMBREAK 2
EASY SELECTION GUIDE

*250A Frame

Beyond the Standard™ page 5


Innovators in Protection Technology
SECTION 1

TEMBREAK 2 MCCBs

REASONS TO USE TEMBREAK 2


1. FIELD-INSTALLABLE ACCESSORIES
• Accessories can be fitted by the switchboard builder or added by the
end-user. All internal accessories are common for TemBreak 2 MCCBs.
• Handles and motor operators can be rapidly fitted using the locking
pegs. It takes less than 10 seconds to secure a handle or motor to
the MCCB – a great time saving compared to alternative products.
• All accessories are endurance tested to the same level
Locking
Pegs as the host MCCB.

2. SAFETY LOCK FOR PLUG-IN VERSIONS

The plug-in MCCB is locked to the base when the toggle


is ON. It cannot be removed unless the toggle is OFF
or TRIPPED. The safety lock prevents a trip occurring
Safety as the MCCB is being removed from the base.
Lock

Plug-in MCCB and base Plug-in connection kit, including safety lock

3. SYMMETRICAL DOOR CUTOUT PATTERNS


Door cutout patterns for
handles are symmetrical,
even when breakers are
mounted in opposite directions.

Using TemBreak 2 Operating Handles Using other MCCB Operating Handles

4. SUPERIOR TEMPERATURE PERFORMANCE


All TemBreak 2 MCCBs are fully rated for use in tropical
environments.
Overheating is the most common cause of failure in electrical
switchgear. You can reduce the likelihood of overheating by using
switchgear with superior temperature performance.

5. MODULAR SIZES
All current ratings up to 630A The compact 125A size
can be supplied in 2 sizes: offers the same features
the 250A and 630A sizes. and performance but with
reduced dimensions and cost.

page 6 Beyond the Standard™


Innovators in Protection Technology

SECTION 1
TEMBREAK 2 MCCBs

REASONS TO USE TEMBREAK 2


6. COMPACT CHANGEOVERS
The mechanical interlock is installed on the front of
the MCCB, and is compatible with motor operators
and handles. An automatic changeover system can
be assembled in a few minutes by a switchboard
builder or end-user.

Changeover Pair with Link Interlock Viewed from Below (250A frame)
and Motor Operators

7. DIRECT OPENING
Under the heading “Measures to minimise the risk in the event of failure”,
IEC 60204-1 Safety of Machinery-Electrical Equipment of Machinery
includes the following recommendation:
“-the use of switching devices having positive (or direct) opening operation.”

8. UNSURPASSED FLEXIBILITY
Overload protection is adjustable between 63%
and 100% of the rating.
Short-circuit protection is adjustable on all
thermal magnetic models.
Short-circuit protection settings are suitable
for motor starting on all models, including
the compact 125A frame.
9. CUSTOMISED TRIPPING TIMES
If you require a characteristic which is not available as a preset on
our electronic protection unit, send us the details and we will
program a customised characteristic to suit your application.
(Within certain limits - contact us for details).

10. VISUAL SAFETY


Coloured indicators display the ON
or OFF status. The indicators are fully
covered if the breaker trips, and black
is the only visible colour.

ON (I) OFF (O) TRIPPED

Beyond the Standard™ page 7


Innovators in Protection Technology
SECTION 1

TEMBREAK 2 MCCBs

WELCOME TO TEMBREAK 2
SAFETY PLUS
Terasaki have an innovative approach to product design.
Our goal is to develop products which not only meet,
but exceed recognised standards.
We use our knowledge of related applications to improve
circuit breaker designs. For instance, when developing
the Direct Opening Action, we applied ideas from
a machinery safety standard to the design of the
TemBreak 2 switching mechanism.
This proactive development policy confirms our
reputation as Innovators in Protection Technology.

Machine Safety

Opening force is Contacts separated Maintenance can


transmitted be performed on
directly from the load side
the toggle switch

TemBreak 2 MCCBs are marked with IEC symbol indicating


Direct Opening Action.
The robust mechanism ensures that the force you apply
to the toggle is transmitted directly to the contacts.

Under the heading “Measures to minimise risk in the event of


failure”, IEC 60204-1 Safety of Machinery - Electrical
Equipment of Machines includes the following
recommendation:

“ - the use of switching devices having positive


(or direct) opening operation.”

TemBreak 2 MCCBs help you to comply with the world’s most


stringent safety standards. It is one of the safest switching
devices for machinery.

page 8 Beyond the Standard™


Innovators in Protection Technology

SECTION 1
TEMBREAK 2 MCCBs

WELCOME TO TEMBREAK 2
SAFETY PLUS
Visual Safety
You can easily see if a breaker is open, closed or tripped. SAFETY+ coloured
indicators boldly display the ON or OFF status. The indicators are fully covered if
a breaker trips, and black is the only visible colour.
This is a unique safety feature. You can identify faulty circuits at a glance.
The toggle position always matches the position of the main contacts.

ON (I) OFF (O) TRIPPED

Touch Safety
The risk of touching live parts has been minimised by design.
These features reduce the risk of touching live parts:
• There are no exposed metal screws on the front face
• No live parts are exposed when fitting accessories
• Double Insulation

Beyond the Standard™ page 9


Innovators in Protection Technology
SECTION 1

TEMBREAK 2 MCCBs

WELCOME TO TEMBREAK 2
EXCEEDING STANDARDS

Safety Plus
TemBreak 2 MCCBs exceed the requirements of recognised
standards.
International Compliance
• The TemBreak 2 MCCB complies with the international
standard IEC 60947-2
• TemBreak 2 Switch Disconnectors comply with
IEC 60947-3
• Accessories comply with IEC 60947-5-1 or IEC 61058-1
• The entire range conforms to the IEC general rules
for switchgear, IEC 60947-1
• TemBreak 2 MCCBs comply with JIS C 8201-2-1 Ann.1
• The TemBreak 2 range complies with the EC Low
Voltage Directive and all models are CE marked
• TemBreak 2 MCCBs carry the IEC symbol indicating
Direct Opening Action as defined by IEC 60947-5-1.
IEC 60204-1, Safety of Machinery - Electrical
Equipment of Machines recommends that switches
used for machinery have Direct Opening Action to
minimise risk in the event of failure

Independent Tests
TemBreak 2 circuit breakers have been tested at independent
laboratories as well as in Terasaki's own laboratory in
Osaka, Japan. Copies of independent test reports are available
on request.

Marine Approvals
TemBreak 2 MCCBs are approved by the leading marine
approval organisations.

Visit www.terasaki.com for current marine approvals


and performance ratings.

page 10 Beyond the Standard™


Innovators in Protection Technology

SECTION 1
TEMBREAK 2 MCCBs

WELCOME TO TEMBREAK 2
REDUCING ENVIRONMENTAL IMPACT
Longer Life Cycle
It makes good environmental sense to install a product
with a long life expectancy. If you install a TemBreak 2
MCCB, you can expect it to stay in service for at least
30,000 mechanical operations (250A Frame). This is
1 22,000 more operations than recommended by
IEC 60947-2, the international standard for circuit breakers.
If a system must be upgraded in future, we have made
the following provisions for recycling:
1 The modular design of TemBreak 2 allows component
parts and accessories to be easily disassembled and
separately disposed of. Moulded parts do not contain any
embedded metal parts.
2 Materials are clearly marked to allow future identification
for easy recycling.

2 Uses Eco-friendly Materials


The following materials are used in most TemBreak 2 circuit
breakers:
• Thermoplastic resin not containing PBBs or PBDEs
• Lead-free solder
• Cadmium-free contacts
• Rohs compliant materials

Lighter and Smaller


Components with low weight and volume make life easy
for users, but high performance from smaller products also
means less material used and less waste produced.

ISO 14001
Terasaki operate an Environmental Management System accredited to ISO 14001:1999. This requires us to monitor
and measure the environmental performance of our activities, products and services in order to continually improve
such performance.

Further information about this standard can be found on the internet at: www.tc207.org

Beyond the Standard™ page 11


TEMBREAK 2 MCCBs

Locking
Pegs

• Accessories can be fitted by the switchboard builder


or added by the end-user. All internal accessories are
common for TemBreak 2 MCCBs.
• Handles and motor operators can be rapidly fitted
using the locking pegs. It takes less than 10 seconds
to secure a handle or motor to the MCCB – a great
time saving compared to alternative products.
• All accessories are endurance tested to the same level
as the host MCCB.
Innovators in Protection Technology

TEMBREAK 2 MCCBs

RATINGS AND SPECIFICATIONS

SECTION 2
TEMBREAK 2
MOULDED CASE CIRCUIT BREAKERS
16A TO 630A

1. Welcome to TemBreak 2
2. Ratings and Specifications
• MCCBs 15

• Switch-Disconnectors 19

3. Operating Characteristics
4. Application Data
5. Accessories
6. Installation
7. Dimensions

Beyond the Standard™ page 13


Innovators in Protection Technology

TEMBREAK 2 MCCBs

MCCB ELECTRICAL CHARACTERISTICS TO IEC 60947-2, EN 60947-2,


JIS C 8201-2-1 ANN.1, AS/NZS 3947-2, NEMA AB-1
SECTION 2

Frame Quantity Unit Condition 125


Model E125 S125
Number of Poles 3, 4 1
Type NJ NF

Nominal current ratings


In (A) 50oC 20,32,50, 16,20,25,
63,100,125 32,40,50,
63, 80,
100,125
Electrical characteristics
Rated operational voltage Ue (V) AC 50/60 Hz 500 240
DC 500 -
Rated insulation voltage Ui (V) 800 800
Rated impulse withstand voltage Uimp (kV) 8 8

Ultimate breaking capacity Icu (kA) 690V AC - -


(IEC, JIS, AS/NZS) 525V AC 8 -
440V AC 15 -
400/415V AC 25 -
220/240V AC 35 25
250V DC 25 -

Service breaking capacity Ics (kA) 690V AC - -


(IEC, JIS, AS/NZS) 525V AC 6 -
440V AC 12 -
400/415V AC 19 -
220/240V AC 27 13
250V DC 19 -

Rated breaking capacity (NEMA) (kA) 480V AC 8 -


240VAC 35 25

Protection
Adjustable thermal, adjustable magnetic
Fixed thermal, fixed magnetic
Microprocessor
Utilisation category A A

Installation
Front connection (FC)
Attached flat bar (FB) • •
Solderless terminal (cable clamp) (FW) • •
Rear connection (RC) • -
Plug-in (PM) • -
Draw- out (DR) - -
DIN rail mounting (DA) • •
Dimensions h (mm) 155 155
w (mm) 3 pole, (1 pole) 90 (30)
4 pole 120
d (mm) 68 68
Weight W (kg) 3 pole, (1 pole) 1.1 (0.45)
4 pole 1.4

Operation
Direct Opening Action
Toggle operation
Variable depth / direct mount operating handle (HB/HP) • -
Motor operator (MC) • -

Endurance Electrical cycles 440V AC


Mechanical cycles

page 14 Beyond the Standard™ Standard • Optional - Not Available


Innovators in Protection Technology

TEMBREAK 2 MCCBs

RATINGS AND SPECIFICATIONS

SECTION 2
160
S125 S125 H125 L125 S160 S160 S160 H160 L160
3, 4 3,4 3, 4 3, 4 1 3, 4 3, 4 3, 4 3, 4
NJ GJ NJ NJ NF NJ GJ NJ NJ

20,32,50, 20,32,50, 20,32,50, 20,32,50, 16,20,25,32, 20,32,50,63, 50,63,100, 160 160


63,100,125 63,100,125 63,100,125 63,100,125 40,50,63,80, 100,125,160 125,160
100,125,160

690 690 690 690 415 690 690 690 690


600 600 600 600 125 600 600 600 600
800 800 800 800 800 800 800 800 800
8 8 8 8 8 8 8 8 8

6 6 20 25 - 7.5 (5*) 7.5 20 25


22 25 45 65 - 25 (18*) 25 45 65
25 50 120 180 - 25 (18*) 50 120 180
36 65 125 200 - 36 (30*) 65 125 200
50 85 150 200 25 65 (42*) 85 150 200
25 40 40 40 - 40 (30*) 40 40 40

6 6 15 20 - 7.5 (5*) 7.5 15 20


22 22 45 65 - 25 (18*) 25 45 65
25 25 80 135 - 25 (18*) 25 80 135
36/30 36/33 85 150 - 36 (25*) 36 85 150
50 85 150 150 19 65 (35*) 85 150 150
19 40 40 40 - 40 (25*) 40 40 40

22 25 45 65 - 22 (18*) 25 45 65
50 85 150 200 25 65 (42*) 85 150 200

A A A A A A A A A

• • • • • • • • •
• • • • • • • • •
• • • • - • • • •
• • • • - • • • •
- - - - - - - - -
• • - - - - - - -
155 155 165 165 165 165 165 165 165
90 90 105 105 (35) 105 105 105 105
120 120 140 140 - 140 140 140 140
68 68 103 103 68 68 68 103 103
1.1 1.1 2.4 2.4 (0.5) 1.5 1.5 2.5 2.5
1.4 1.4 3.2 3.2 1.9 1.9 3.3 3.3

• • • • - • • • •
• • • • - • • • •

30,000 20,000
30,000 20,000 30,000

*Applies only to 20A and 32A models Beyond the Standard™ page 15
Innovators in Protection Technology

TEMBREAK 2 MCCBs

MCCB ELECTRICAL CHARACTERISTICS TO IEC 60947-2,


EN 60947-2, JIS C 8201-2-1 ANN.1, AS/NZS 3947-2, NEMA AB-1
SECTION 2

Frame Quantity Unit Condition 250


Model E250 S250 S250
Number of Poles 3, 4 3, 4 3, 4
Type NJ NJ GJ

Nominal current ratings


In (A) 50oC 20,32,50,63 160,200, 160,200,
100,125,160, 250 250
200,250

Electrical characteristics
Rated operational voltage Ue (V) AC 50/60 Hz 500 690 690
DC 500 600 600
Rated insulation voltage Ui (V) 800 800 800
Rated impulse withstand voltage Uimp (kV) 8 8 8

Ultimate breaking capacity Icu (kA) 690V AC - 7.5 7.5


(IEC, JIS, AS/NZS) 525V AC 10 25 25
440V AC 15 25 50
400/415V AC 25 36 65
220/240V AC 35 65 85
250V DC 25 40 40

Service breaking capacity Ics (kA) 690V AC - 7.5 7.5


(IEC, JIS, AS/NZS) 525V AC 7.5 25 25
440V AC 12 25 25
400/415V AC 19 36 36
220/240V AC 27 65 85
250V DC 19 40 40

Rated breaking capacity (NEMA) (kA) 480V AC 10 22 25


240VAC 35 65 85

Rated short-time withstand current Icw (kA) 0.3 Seconds - - -

Protection
Adjustable thermal, adjustable magnetic
Fixed thermal, fixed magnetic
Microprocessor
Utilisation category A A A

Installation
Front connection (FC)
Attached flat bar (FB) • • •
Solderless terminal (cable clamp) (FW) • • •
Rear connection (RC) • • •
Plug-in (PM) • • •
Draw- out (DR) - - -
DIN rail mounting (DA) - - -
Dimensions h (mm) 165 165 165
w (mm) 3 pole 105 105 105
(mm) 4 pole 140 140 140
d (mm) 68 68 68
Weight W (kg) 3 pole 1.5 1.5 1.5
4 pole 1.9 1.9 1.9

Operation
Direct Opening Action
Toggle operation
Variable depth / direct mount operating handle (HB/HP) • • •
Motor operator (MC)
Endurance Electrical cycles 415V AC
Mechanical cycles

page 16 Beyond the Standard™ Standard • Optional - Not Available


Innovators in Protection Technology

TEMBREAK 2 MCCBs

RATINGS AND SPECIFICATIONS

SECTION 2
400 630
S250 H250 H250 L250 E400 S400 S400 S400 S400 S400 H400 H400 L400 L400 E630 S630 S630 >630
3, 4 3, 4 3, 4 3, 4 3, 4 3, 4 3, 4 3,4 3, 4 3, 4 3, 4 3, 4 3, 4 3, 4 3,4 3, 4 3, 4
PE NJ NE NJ NJ CJ NJ NE GJ GE NJ NE NJ NE NE CE GE

250, 160, 250, 160, 250, 250, 250, 250, 250, 250, 250, 250, 250, 250, 630 630 630
125 250 125 250 400 400 400 400 400 400 400 400 400 400

690 690 690 690 500 690 690 690 690 690 690 690 690 690 690* 690* 690*

TURN TO PAGE 143, SECTION 9, FOR RATINGS AND SPECIFICATIONS OF MCCBs FROM 630A TO 1600A
- 600 - 600 500 600 600 - 600 - 600 - 600 - - - -
800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800
8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8

20 20 20 25 - 15 20 20 20 20 35 35 50 50 10* 20* 20*


35 45 45 65 15 22 30 30 30 30 45 45 65 65 15 30 30
50 120 120 180 22 30 45 45 65 65 120 120 180 180 25 45 65
70 125 125 200 25 36 50 50 70 70 125 125 200 200 36 50 70
125 150 150 200 35 50 85 85 100 100 150 150 200 200 50 85 100
- 40 - 40 25 40 40 - 40 - 40 - 40 - - - -

15 15 15 20 - 15 15 15 15 15 35 35 50 50 10* 15* 15*


35 45 45 65 15 22 30 30 30 30 45 45 65 65 15 30 30
50 80 80 135 22 30 45 45 50 50 80 80 135 135 25 45 50
70 85 85 150 25 36 50 50 50 50 85 85 150 150 36 50 50
125 150 150 150 35 50 85 85 85 85 150 150 150 150 50 85 85
- 40 - 40 19 40 40 - 40 - 40 - 40 - - - -

35 45 45 65 15 22 25 25 30 30 45 45 65 65 15 25 30
125 150 150 200 35 50 85 85 100 100 150 150 200 200 50 85 100

- - - - - - - 5 - 5 - 5 - 5 - - -

A A A A A A A B A B A B A B A A A

• • • • • • • • • • • • • • • • •
• • • • • • • • • • • • • • - - -
• • • • • • • • • • • • • • • • •
• † † † • • • • • • • • • •
- - - - • • • • • • • • • • - - -
- - - - - - - - - - - - - - - - -
165 165 165 165 260 260 260 260 260 260 260 260 260 260 260 260 260
105 105 105 105 140 140 140 140 140 140 140 140 140 140 140 140 140
140 140 140 140 185 185 185 185 185 185 185 185 185 185 185 185 185
103 103 103 103 103 103 103 103 103 103 140 140 140 140 103 103 103
2.5 2.4 2.5 2.4 4.2 4.2 4.2 4.3 4.2 4.3 7.0 7.1 7.0 7.1 5.0 5.0 5.0
3.3 3.2 3.3 3.2 5.6 5.6 5.6 5.7 5.6 5.7 9.3 9.4 9.3 9.4 6.5 6.5 6.5

• • • • • • • • • • • • • • • • •
10,000 4,500 4,500
30,000 15,000 15,000

*MCCB cannot be used in IT systems at this voltage.


† Refer to Temperature Ratings, Section 6.
Beyond the Standard™ page 17
Contact NHP for details.
Innovators in Protection Technology

TEMBREAK 2 MCCBs

SWITCH-DISCONNECTOR ELECTRICAL CHARACTERISTICS


TO IEC 60947-3, EN 60947-3, AS/NZS 3947-3
SECTION 2

Frame Quantity Unit Condition 125 160 250


Model S125 S160 S250
Number of Poles 3,4 3,4 3,4
Type NN NN NN

Nominal current ratings


Ie (A) 125 160 250

Electrical characteristics
Rated operational voltage Ue (V) AC 50/60 Hz 690 690 690
DC 600 600 600
Rated insulation voltage Ui (V) 800 800 800
Rated impulse withstand voltage Uimp (kV) 8 8 8

Rated short -circuit making capacity Icm (kA peak) 3.6 6 6


Rated short-time withstand current Icw (kA rms) 0.3 Seconds 2 3 3
Utilisation category to IEC 60947-3 AC AC-23A AC-23A AC-23A
DC DC-22A DC-22A DC-22A
Installation
Front connection (FC)
Attached flat bar (FB) • • •
Solderless terminal • • •
Rear connection (RC) • • •
Plug-in (PM) • • •
Draw- out (DR) - - -
DIN rail mounting (DA) • - -
Dimensions h (mm) 155 165 165
w (mm) 3 pole 90 105 105
4 pole 120 140 140
d (mm) 68 68 68
Weight W (kg) 3 pole 1.1 1.5 1.5
4 pole 1.4 1.9 1.9
Operation
Direct Opening Action
Toggle operation
Variable depth / direct mount operating handle (HB/HP) • • •
Motor operator (MC) • • •
Endurance Electrical cycles 415V AC 30,000 20,000 10,000
Mechanical cycles 30,000 30,000 30,000

page 18 Beyond the Standard™ Standard • Optional - Not Available


Innovators in Protection Technology

TEMBREAK 2 MCCBs

RATINGS AND SPECIFICATIONS

SECTION 2
400 630
S400 S630
3,4 3,4
NN NN

400 630

690 690
600 600
800 800
8 8

9 9
5 5
AC-23A AC-23A
DC-22A DC-22A

• •
• •
• •

- -
- -
260 260
140 140
185 185
103 103
4.2 4.4
5.6 5.8

• •
• •
4,500 4,500
15,000 15,000

Contact us for details. Beyond the Standard™ page 19


Combined Overcurrent & Earth Fault Relay
www.itmikro.com

NX1000A
Features
• Microprocessor based numerical relay
• Current measurement based on fundamental
frequency
• Three-phase, low-set overcurrent
• Three-phase, high-set overcurrent
• Low-set earth-fault
• High-set earth-fault


• Local display of measured and set values
• Programmable relay outputs


• Complies with IEC 60255 standard
• ANSI Code : 50P, 50N, 51P, 51N

Technical Data
RATINGS SETTING RANGES INDICATORS
Rated current ( In ) :5 A I RCURRENT ELEMENT Auxiliary supply : Green indicator
Rated frequency : 50 or 60 Hz Low-set ( I> ) : 0.1 A to 10.0 A Pick-up : Red indicator
Burden : < 0.3 VA at In (2% to 200%) Trip : 7-segment display
Themal withstand : 4 x In : 0.01 to 1.0 and Red indicators
AUXILIARY SUPPLY : 0.00 sec to 100 sec
Model NX1000A-240A : 198 ~ 265 V AC High-set ( I>> ) : 0.5 A to 100 A
Model NX1000A-240AD : 85 ~ 265 V AC (10% to 2000%) ENVIRONMENTAL CONDITIONS
110 ~ 340 V DC or disable Temperature : -10˚C to +55˚C
Model MK1000A-150D : 24 ~ 150 V DC : 0.00 sec to 100 sec Humidity : 5% to 95%,
Supply frequency : 50 or 60 Hz non-condensing
: 3 VA typical
II EART FAULT ELEMENT
ACCURACY Low-set ( Io> ) : 0.10 A to 5.0 A,
: ± 5% (2% to 100%) MECHANICAL
Time delay : ± 5% with a o>) : 0.01 to 1.0 :
minimum of 50 ms o> ) : 0.00 sec to 100 sec Dimension (mm) : 96(w) x 96(h) x 110(d)
High-set ( Io>> ) : 0.10 A to 50 A : IP54 at the panel
OUTPUT CONTACTS (2% to 1000%) Approximate weight : 0.8 kg
Trip Contacts ( R1 & R2 ) or disable
Rated voltage : 250V AC / DC o>> ) : 0.00 sec to 100 sec
:5A
Expected electrical life (0.00 to 1.00, step 0.01; 1.00 to 10.0, step 0.10;
at rated current 10.0 to 100, step 0.5)
Expected mechanical life : 5 x 106
NX 1000A
Combined Overcurrent & Earth Fault Relay

www.itmikro.com

Normal Inverse Very Inverse Long Time Inverse Extremely Inverse

Normal Inverse 1.3/10 Typical Application Diagram Case Dimensions


96 mm
NX1000A

96 mm
Front

110 mm
100 mm

Side

91.0 ± 0.5 mm

91.0 ± 0.5 mm

Panel Cutout

Ordering Information
MODEL DESCRIPTION
NX1000A-240A For 50/60 Hz system, auxiliary voltage 198 ~ 265 V AC
NX1000A-240AD For 50/60 Hz system, auxiliary voltage 85 ~ 265 V AC or 110~340 V DC
NX1000A-150D For 50/60Hz system, auxiliary voltage 24 ~ 150 V DC
NX 1000A
APPROVAL

TECHNICAL SPECIFICATIONS

HM-C HM-1

45
Power Factor Regulator
PFR140
PFR120
PFR80
PFR60
Features
• Microprocessor based intelligent auto switching
control

• Automatic C/K and rated step adjustment

• Automatic CT polarity correction

• Display of power factor, current & total harmonic


distortion of current

• Programmable sensitivity

• Last step can be used as alarm/fan output

• Under/over voltage alarm, under/over compensate


alarm & high harmonic distortion alarm

• User-friendly setting

• Complies with IEC 61000-6-2 standard

Technical Data
RATINGS AUXILIARY POWER SUPPLY CURRENT INPUT ENVIRONMENTAL CONDITIONS
Current Supply voltage : 220~240 V AC / Rated current ( In ) :5A Temperature : -5˚C to +55˚C
380~415 V AC Operating Limits : 0.05 A to 6.5 A Humidity : 56 days at 93% RH and
Operating Limits : -15% + 10% Rated Frequency : 50 Hz or 60 Hz 40˚C non-condensing
Consumption : 10 VA max
PFR 140 / 120 / 80 / 60

Rated frequency : 50 Hz or 60 Hz
CONTROL RANGE MECHANICAL
Power factor setting : 0.8 Ind - 0.8 Cap Mounting : Panel mounting
OUTPUT CONTACTS C/K setting : 0.03 - 1.20 / Automatic Dimension (mm) : 144(w) x 144(h) x 90(d)
Numbers of outputs : 6 / 8 / 12 / 14 ( PFR60 Switching sensitivity : 5 - 600 s/step Enclosure protection : IP54 at the panel
/ PFR80 / PFR120 / Reconnection time for Approximate weight : 1.2 kg
PFR140 ) same step : 5 - 240 s
Rated voltage : 250 V AC THD threshold : 0.20 - 3.00 ( 20% - 300% ) /
Contact rating : 5A OFF
Expected electrical life : 100,000 operations at Switching Program : Automatic / Automatic
rated current Rotate / 4-quadrant /
Expected mechanical life : 5 x 106 operations Manual
Max current for the Rated step coefficient : 0 / 1 / 2 / 3 / 4 / 5 / 6 / 8 /
common terminals : 12 A continuous 12 / 16
( Automatic if C/K set to
Auto )
Power Factor Regulator

Typical Application Diagram

MAIN
N L3 L2 L1
13 13

220~240 V AC
AUX AUX

380~415 V AC
VOLTAGE 1 VOLTAGE
14 14
2

Power Factor Regulator


1
15 2 3 15
16 3 4 16
P1 17 5
CURRENT 4
18 6 For 220~240 V AC Model Only
/5A 5
P2 19 6 7
20 11 7 8
21 12 8 9
22 13 9 10
23 14 10 11
24 12
FUSE

K14 K13 K2 K1

LOAD

Ordering Information Case Dimensions


144 mm

MODEL DESCRIPTION
PFR60 - 415 - 50 6 Steps, 50 Hz system, auxiliary voltage 380~415 V AC
144 mm

PFR80 - 415 - 50 8 Steps, 50 Hz system, auxiliary voltage 380~415 V AC Front


PFR120 - 415 - 50 12 Steps, 50 Hz system, auxiliary voltage 380~415 V AC
PFR140 - 415 - 50 14 Steps, 50 Hz system, auxiliary voltage 380~415 V AC
PFR60 - 220 - 50 6 Steps, 50 Hz system, auxiliary voltage 220~240 V AC
PFR80 - 220 - 50 8 Steps, 50 Hz system, auxiliary voltage 220~240 V AC 90 mm
76 mm
PFR120 - 220 - 50 12 Steps, 50 Hz system, auxiliary voltage 220~240 V AC
PFR 140 / 120 / 80 / 60

PFR140 - 220 - 50 14 Steps, 50 Hz system, auxiliary voltage 220~240 V AC


PFR60 - 415 - 60 6 Steps, 60 Hz system, auxiliary voltage 380~415 V AC
Side
PFR80 - 415 - 60 8 Steps, 60 Hz system, auxiliary voltage 380~415 V AC
PFR120 - 415 - 60 12 Steps, 60 Hz system, auxiliary voltage 380~415 V AC
PFR140 - 415 - 60 14 Steps, 60 Hz system, auxiliary voltage 380~415 V AC
PFR60 - 220 - 60 6 Steps, 60 Hz system, auxiliary voltage 220~240 V AC
138 mm
PFR80 - 220 - 60 8 Steps, 60 Hz system, auxiliary voltage 220~240 V AC
PFR120 - 220 - 60 12 Steps, 60 Hz system, auxiliary voltage 220~240 V AC
PFR140 - 220 - 60 14 Steps, 60 Hz system, auxiliary voltage 220~240 V AC
138 mm

Panel
Cutout
Low Voltage Switches

Switches
Switch fuses
OS32...160 A Gamma series
Switch fuses for extreme conditions
- OS 32…160 Gamma series

Numerous applications require switch fuses that can


withstand extreme conditions. High voltages and high
short circuit currents create a demand for superior
performance without neglecting safety.

Superior performance
- High U i ratings
- High CTI in supporting parts
- The contact constructions are optimal, regardless of fuse
type, DIN, BS, NFC or UL-type
- Meets the requirements for installation close to the main
transformer up to 100 kA in heavy industry and in ships

High performance level and smart design makes OS


Our new series comprises of
Gamma switch fuses suitable for all applications in low two frame sizes OS32G_...63G_
voltage networks. and OS100G_...160G_.

Compact construction
- Intelligent construction in combination with a small number
of components results in a very compact mechanism
design
- Very small footprint area

Space savings mean cost reduction!

Designed for safety


- The frame is made of robust plastic with excellent
mechanical and thermal properties.
- Voltage output pins (as standard)
- Pole markings as standard
- The fuse covers cannot be opened while the switch fuse
is in the ON-position and can be sealed in the closed
position.

You take no risks with OS32...160 Gamma switch fuses

2 Product overview | Switch fuses OS32...160 A Gamma series


Switch fuses OS32G_...160G_
Technical data

Technical data according to IEC 60947-3

OS OS OS OS OS OS
Switch size A 32 50 63 100 125 160
Rated insulation voltage Pollution degree 3 V 1 000 1 000 1 000 1 000 1 000 1 000
Dielectric strength 50 Hz 1min. kV 10 10 10 10 10 10
Rated thermal current in ambient 40 °C 2)
/ In open air A/W 32/7.5 50/7.5 63/7.5 100/12 125/12 160/12
max. fuse power dissipation 1) In enclosure A/W 32/7.5 50/7.5 63/7.5 100/12 125/12 160/12
...with minimum cable cross section Cu mm 2 6 10 16 50 50 70
Rated operational voltage AC-20 and DC-20 V 1 000 1 000 1 000 1 000 1 000 1 000
Rated operational current, AC-21, AC-22 and AC 23 A 32 50 63 100 125 160
Rated operational current / poles in series DC-21A 48 V A 32/2 50/2 63/2 100/2 125/2 160/2
110-220 V A 32/2* 50/2* 63/2* 100/2* 125/2* 125/2*
440 V A 32/4* 50/4* 50/4* 100/4* 125/4* 125/4*
Rated operational current / poles in series DC-22A 48 V A 32/2 50/2 63/2 100/2 125/2 160/2
110-220 V A 32/2* 50/2* 63/2* 100/2* 125/2* 125/2*
Rated operational current / poles in series DC-23A 48 V A 32/2 50/2 63/2 100/2 125/2 160/2
110-220 V A 32/2* 50/2* 63/2* 100/2* 125/2* 125/2*
Rated operational power, AC-23 4) 230 V kW 7.5 11 18.5 30 37 45
The kW-ratings are accurate 400 V kW 15 22 30 55 55 75
for three-phase 1500 R.P.M. 415 V kW 15 22 30 55 55 75
standard asynchronous motors. 500 V kW 18.5 30 37 55 75 90
690 V kW 22 37 55 90 110 132
Rated breaking capacity in category AC-23 up to 690 V A 504 504 504 1 280 1280 1280
Rated breaking capacity / poles in series in category DC-23 up to 220 V A 252/2 252/2 252/2 640/2 640/2 640/2
Rated conditional short-circuit current I p (r.m.s.) 80 kA, 415 V kA 13.5 13.5 13.5 23.5 23.5 23.5
I p (r.m.s.) and corresponding max. allowed Fuse size gG/aM A 80/63 80/63 80/63 160/160 160/160 160/160
cut-off current î c Ip (r.m.s.) 100 kA, 500 V kA 12.5 12.5 12.5 25.5 25.5 25.5
Fuse size gG/aM A 63/63 63/63 63/63 160/160 160/160 160/160
I p (r.m.s.) 80 kA, 690 V kA 11.5 11.5 11.5 20.5 20.5 20.5
Fuse size gG/aM A 63/63 63/63 63/63 125/160 125/160 125/160
Rated short-time withstand current, 1s r.m.s. -value kA 2.5 2.5 2.5 5 5 5
Rated capacitor power 5)
400/415/690 V A 15/15/25 20/25/42 25/32/50 40/42/75 50/55/90 60/65/100

Power loss / pole With rated current, without fuse W 1 2.5 4 4 5 9


Mechanical endurance Divide by two for oper. cycles Oper. 20 000 20 000 20 000 20 000 20 000 20 000
Fuse types, IEC 60269-2-1 DIN 43620 000 000 000, 00 000, 00
NFC 63210, 63211 14x51 22x58
BS 88-2, -6 -size / A2-A3 A2-A3 A2-A4 3) A2-A43) A2-A43)
distance of fuse-link bolts mm M5/73 M5/73 M5/73, M5/73, M5/73,
M8/94 M8/94 M8/94
Weight without accessories 3-pole switch fuses kg 1.3 1.3 1.3 1.5 1.5 1.5
4-pole switch fuses kg 1.6 1.6 1.6 1.8 1.8 1.8
Built-in terminal size Cu mm 2 2.5...25 2.5...25 2.5...25
Terminal bolt size (included) Metric thread diameter x length mm M8x25 M8x25 M8x25
Terminal tightening torque Counter torque required Nm 4 4 4 15-22 15-22 15-22
Fuse-links bolts tightening torque Nm 3.5 3.5 M5:3.5 M5:3.5 M5:3.5
M8:5 M8:5 M8:5
Operating torque Typical for 3-pole switch fuses Nm 5 5 5 7 7 7

Placing options of the operating mechanism *)


Utilization category B
1)
Ambient temperature 60 °C: derating 20%.
2)
Acc. to IEC 60947-1, § 6.1.1.
3)
Max. fuse body diam. 32 mm.
4)
Some fuse links limit these figures further. Starting current
characteristics must be considered separately.
5)
The capacitor rating of the switch-fuse is limited by the
fuse link.
At the end of the switch Between the poles Side operated types The technical data is valid at the time of printing.
fuse OS_03 or 04 OS_12 or 22 OS_30 or 40 We reserve the right to subsequent alterations.

Switch fuses OS32...160 A Gamma Series | Technical data 3


Switch fuses OS32G...160G_, DIN-types
Ordering information

Front operated switch fuses


Including a black ON-OFF plastic handle and shaft as standard. OS32G_...63G_ include protected
tunnel terminals (IP20) and OS125G...160G include a terminal bolt kit. The handle is IP65 protected,
padlockable in the OFF-position and with door interlock in the ON-position and when padlocked. The
shaft is adjustable for a range of installation depths.
ON NO
I
A04172

Rated op. Rated op. Fuse Number Type Order number Units/ Weight/
F
F
A04172

current power size of type unit


O OF F

AC-20...23 AC-23 poles [pcs] [kg]


≤ 690V 400/500/690V
[A] [kW]
OS32G_...63G_03P
Mechanism between the poles
32 15/18.5/22 000 3 OS32GD12P 1SCA114581R1001 1 1.3
32 15/18.5/22 000 4 OS32GD22N2P 1SCA115202R1001 1 1.6
63 30/37/55 000 3 OS63GD12P 1SCA115227R1001 1 1.3
63 30/37/55 000 4 OS63GD22N2P 1SCA115230R1001 1 1.6
125 55/75/110 000, 00 3 OS125GD12P 1SCA115641R1001 1 1.5
ON
125 55/75/110 000, 00 4 OS125GD22N2P 1SCA115880R1001 1 1.8
NO

160 75/90/132 000, 00 3 OS160GD12P 1SCA115643R1001 1 1.5


I
O
A04173

F
F

160 75/90/132 000, 00 4 OS160GD22N2P 1SCA115884R1001 1 1.8


A04173

O OF F

Mechanism at the end of the switch fuse


32 15/18.5/22 000 3 OS32GD03P 1SCA115189R1001 1 1.3
OS125G_...160G_03P 32 15/18.5/22 000 4 OS32GD04N2P 1SCA115193R1001 1 1.6
63 30/37/55 000 3 OS63GD03P 1SCA115207R1001 1 1.3
63 30/37/55 000 4 OS63GD04N2P 1SCA115209R1001 1 1.6
125 55/75/110 000, 00 3 OS125GD03P 1SCA115639R1001 1 1.5
125 55/75/110 000, 00 4 OS125GD04N2P 1SCA115877R1001 1 1.8
160 75/90/132 000, 00 3 OS160GD03P 1SCA115399R1001 1 1.5
160 75/90/132 000, 00 4 OS160GD04N2P 1SCA115882R1001 1 1.8

Side operated switch fuses without handle and shaft


S07014
S07014

OS32G_...63G_ include protected tunnel terminals (IP20) and OS125G...160G include a terminal bolt kit.

OS32G_...63GDS30 Rated op. Rated op. Fuse Number Type Order number Units/ Weight/
current power size of type unit
AC-20...23 AC-23 poles [pcs] [kg]
≤ 690V 400/500/690V
[A] [kW]

32 15/18.5/22 000 3 OS32GDS30 1SCA115963R1001 1 1.3


32 15/18.5/22 000 4 OS32GDS40N2 1SCA116046R1001 1 1.6
63 30/37/55 000 3 OS63GDS30 1SCA116007R1001 1 1.3
63 30/37/55 000 4 OS63GDS40N2 1SCA116047R1001 1 1.6
125 55/75/110 000, 00 3 OS125GDS30 1SCA115966R1001 1 1.5
S07015

125 55/75/110 000, 00 4 OS125GDS40N2 1SCA115967R1001 1 1.8


S07015

160 75/90/132 000, 00 3 OS160GDS30 1SCA115968R1001 1 1.5


160 75/90/132 000, 00 4 OS160GDS40N2 1SCA115969R1001 1 1.8
OS125G_...160GDS30

Shafts and handles included as standard /


Front operated switch fuses
Suitable for switches Included shaft Included handle Included terminal bolts

OS32G_...63G_ OXP6X161 OHB45J6


OS125G_...160G_ OXP6X161 OHB65J6 M8x25

OS_N2_ = Non-fused neutral on the right side

4 Ordering information | Switch fuses OS32...160 A Gamma series


Switch fuses OS32G...160G_, BS-types
Ordering information

Front operated switch fuses


Including a black ON-OFF plastic handle and shaft as standard. OS32G_...63G_ include protected
tunnel terminals (IP20) and OS100G...160G include a terminal bolt kit. The handle is IP65 protected,
padlockable in the OFF-position and with door interlock in the ON-position and when padlocked. The
shaft is adjustable for a range of installation depths.
ON NO
I
A04172

Rated op. Rated op. Fuse Number Type Order number Units/ Weight/
F
F
A04172

current power size of type unit


O OF F

AC-20...23 AC-23 poles [pcs] [kg]


≤ 690V 400/500/690V
[A] [kW]
OS32G_...63G_03P
Mechanism between the poles
32 15/18.5/22 A2, A3 3 OS32GB12P 1SCA115331R1001 1 1.3
32 15/18.5/22 A2, A3 4 OS32GB22N1P 1SCA115345R1001 1 1.6
63 30/37/55 A2, A3 3 OS63GB12P 1SCA115325R1001 1 1.3
63 30/37/55 A2, A3 4 OS63GB22N1P 1SCA114601R1001 1 1.6
100 55/55/90 A2, A3, A41) 3 OS100GB12P 1SCA114586R1001 1 1.5
ON
100 55/55/90 A2, A3, A41) 4 OS100GB22N1P 1SCA114602R1001 1 1.8
NO

125 55/75/110 A2, A3, A41) 3 OS125GB12P 1SCA114603R1001 1 1.5


I
O
A04173

F
F

125 55/75/110 A2, A3, A41) 4 OS125GB22N1P 1SCA115903R1001 1 1.8


A04173

O OF F

160 75/90/132 A2, A3, A41) 3 OS160GB12P 1SCA115637R1001 1 1.5


160 75/90/132 A2, A3, A41) 4 OS160GB22N1P 1SCA115899R1001 1 1.8

OS100G_...160G_03P Mechanism at the end of the switch fuse


32 15/18.5/22 A2, A3 3 OS32GB03P 1SCA115259R1001 1 1.3
32 15/18.5/22 A2, A3 4 OS32GB04N1P 1SCA114610R1001 1 1.6
63 30/37/55 A2, A3 3 OS63GB03P 1SCA115235R1001 1 1.3
63 30/37/55 A2, A3 4 OS63GB04N1P 1SCA115238R1001 1 1.6
100 55/55/90 A2, A3, A41) 3 OS100GB03P 1SCA114613R1001 1 1.5
100 55/55/90 A2, A3, A41) 4 OS100GB04N1P 1SCA114614R1001 1 1.8
125 55/75/110 A2, A3, A41) 3 OS125GB03P 1SCA115634R1001 1 1.5
125 55/75/110 A2, A3, A41) 4 OS125GB04N1P 1SCA115901R1001 1 1.8
160 75/90/132 A2, A3, A41) 3 OS160GB03P 1SCA115413R1001 1 1.5
S07014
S07014

160 75/90/132 A2, A3, A41) 4 OS160GB04N1P 1SCA115896R1001 1 1.8

OS32G_...63GBS30
Side operated switch fuses without handle and shaft
OS32G_...63G_ include protected tunnel terminals (IP20) and OS100G...160G include a terminal bolt kit.

Rated op. Rated op. Fuse Number Type Order number Units/ Weight/
current power size of type unit
AC-20...23 AC-23 poles [pcs] [kg]
≤ 690V 400/500/690V
[A] [kW]

32 15/18.5/22 A2, A3 3 OS32GBS30 1SCA115955R1001 1 1.3


S07015

32 15/18.5/22 A2, A3 4 OS32GBS40N1 1SCA115956R1001 1 1.6


S07015

63 30/37/55 A2, A3 3 OS63GBS30 1SCA115957R1001 1 1.3


63 30/37/55 A2, A3 4 OS63GBS40N1 1SCA115978R1001 1 1.6
OS100G_...160GBS30 100 55/55/90 A2, A3, A41) 3 OS100GBS30 1SCA116758R1001 1 1.5
100 55/55/90 A2, A3, A41) 4 OS100GBS40N1 1SCA116759R1001 1 1.8
100 55/55/90 A2, A3, A41) 4 OS100GBS40N2 1SCA116760R1001 1 1.8
125 55/75/110 A2, A3, A41) 3 OS125GBS30 1SCA116048R1001 1 1.5
125 55/75/110 A2, A3, A41) 4 OS125GBS40N1 1SCA115959R1001 1 1.8
160 75/90/132 A2, A3, A41) 3 OS160GBS30 1SCA115960R1001 1 1.5
160 75/90/132 A2, A3, A41) 4 OS160GBS40N1 1SCA115961R1001 1 1.8

Shafts and handles included as standard /


Front operated switch fuses
Suitable for switches Included shaft Included handle Included terminal bolts

OS32G_...63G_ OXP6X161 OHB45J6


OS100G_...160G_ OXP6X161 OHB65J6 M8x25

1) Max. fuse diameter 32 mm


OS_N1_ = Non-fused neutral on the left side
OS_N2_ = Non-fused neutral on the right side

Switch fuses OS32...160 A Gamma Series | Ordering information 5


Switch fuses OS32G...160G_, NFC-types
Ordering information

Front operated switch fuses


Including a black ON-OFF plastic handle and shaft as standard. OS50G_ include protected tunnel
terminals (IP20) and OS125G include a terminal bolt kit. The handle is IP65 protected, padlockable
in the OFF-position and with door interlock in the ON-position and when padlocked. The shaft is
ON NO
adjustable for a range of installation depths.
I
A04172

O
F

Rated op. Rated op. Fuse Number Type Order number Units/ Weight/
F
A04172

O OF F

current power size of type unit


AC-20...23 AC-23 poles [pcs] [kg]
≤ 690V 400/500/690V
[A] [kW]
OS50G_03P
Mechanism between the poles
50 22/30/37 14x51 3 OS50GF12P 1SCA115553R1001 1 1.3
50 22/30/37 14x51 4 OS50GF22N1P 1SCA114622R1001 1 1.6
50 22/30/37 14x51 4 OS50GF22FP 1SCA114623R1001 1 1.6
125 55/75/110 22x58 3 OS125GF12P 1SCA114624R1001 1 1.5
125 55/75/110 22x58 4 OS125GF22N1P 1SCA115893R1001 1 1.8
ON
125 55/75/110 22x58 4 OS125GF22FP 1SCA115614R1001 1 1.8
NO
I

Mechanism at the end of the switch fuse


O
A04173

F
F
A04173

50 22/30/37 14x51 3 OS50GF03P 1SCA115492R1001 1 1.3


O OF F

50 22/30/37 14x51 4 OS50GF04N1P 1SCA115495R1001 1 1.6


50 22/30/37 14x51 4 OS50GF04FP 1SCA115498R1001 1 1.6
OS125G_03P 125 55/75/110 22x58 3 OS125GF03P 1SCA115602R1001 1 1.5
125 55/75/110 22x58 4 OS125GF04N1P 1SCA115888R1001 1 1.8
125 55/75/110 22x58 4 OS125GF04FP 1SCA115606R1001 1 1.8

Side operated switch fuses without handle and shaft


OS50G_ include protected tunnel terminals (IP20) and OS125G include a terminal bolt kit.

Rated op. Rated op. Fuse Number Type Order number Units/ Weight/
current power size of type unit
S07014

AC-20...23 AC-23 poles [pcs] [kg]


S07014

≤ 690V 400/500/690V
[A] [kW]
OS50GFS30
50 22/30/37 14x51 3 OS50GFS30 1SCA116050R1001 1 1.3
50 22/30/37 14x51 4 OS50GFS40N1 1SCA116058R1001 1 1.6
50 22/30/37 14x51 4 OS50GFS40F 1SCA116014R1001 1 1.6
125 55/75/110 22x58 3 OS125GFS30 1SCA115973R1001 1 1.5
125 55/75/110 22x58 4 OS125GFS40N1 1SCA115974R1001 1 1.8
125 55/75/110 22x58 4 OS125GFS40F 1SCA115975R1001 1 1.8

Shafts and handles included as standard /


S07015

Front operated switch fuses


S07015

Suitable for switches Included shaft Included handle Included terminal bolts
OS125GFS30
OS50G_ OXP6X161 OHB45J6
OS125G_ OXP6X161 OHB65J6 M8x25

OS_N1_ = Non-fused neutral on the left side


OS_F_ = Fused neutral

6 Ordering information | Switch fuses OS32...160 A Gamma series


Switch fuses OS32G...160G_, UL-types
Ordering information

Front operated switch fuses


Including a black ON-OFF plastic handle and shaft as standard. OS60G_ include protected tunnel
terminals (IP20) and OS100G_include a terminal bolt kit. The handle is IP65 protected, Nema type
1, 3R, 12, padlockable in the OFF-position and with door interlock in the ON-position and when
ON NO
padlocked. The shaft is adjustable for a range of installation depths.
I
A04172

O
F

Ampere Horse power Fuse Number Type Order number Units/ Weight/
F
A04172

O OF F

rating ratings size of type unit


[A] 3-phase poles [pcs] [kg]
240/480/600V
[HP]
OS60G_03P
Mechanism between the poles
60 15/30/50 J, 60A 3 OS60GJ12P 1SCA115449R1001 1 1.3
60 15/30/50 J, 60A 4 OS60GJ22FP 1SCA115469R1001 1 1.6
100 30/60/75 J, 100A 3 OS100GJ12P 1SCA115666R1001 1 1.5
100 30/60/75 J, 100A 4 OS100GJ22FP 1SCA114636R1001 1 1.8

ON
Mechanism at the end of the switch fuse
60 15/30/50 J, 60A 3 OS60GJ03P 1SCA115443R1001 1 1.3
NO
I
O
A04173

F
F

60 15/30/50 J, 60A 4 OS60GJ04FP 1SCA115446R1001 1 1.6


A04173

O OF F

100 30/60/75 J, 100A 3 OS100GJ03P 1SCA114639R1001 1 1.5


100 30/60/75 J, 100A 4 OS100GJ04FP 1SCA115439R1001 1 1.8

OS100G_03P
Side operated switch fuses without handle and shaft
OS60G_ include protected tunnel terminals (IP20) and OS100G include a terminal bolt kit.

Ampere Horse power Fuse Number Type Order number Units/ Weight/
rating ratings size of type unit
[A] 3-phase poles [pcs] [kg]
240/480/600V
[HP]

60 15/30/50 J, 60A 3 OS60GJS30 1SCA116051R1001 1 1.3


S07014

60 15/30/50 J, 60A 4 OS60GJS40F 1SCA115970R1001 1 1.6


S07014

100 30/60/75 J, 100A 3 OS100GJS30 1SCA115971R1001 1 1.5


100 30/60/75 J, 100A 4 OS100GJS40F 1SCA115972R1001 1 1.8
OS60GJS30

Shafts and handles included as standard /


Front operated switch fuses
Suitable for switches Included shaft Included handle Included terminal bolts

OS60G_ OXP6X161 OHB45J6


S07016

OS100G_ OXP6X161 OHB65J6 M8x25


S07016

OS100GJS30

Switch fuses OS32...160 A Gamma Series | Ordering information 7


Accessories
Ordering information

Optional handles, IP 65
For front operated switch fuses
Padlockable with 3 padlocks in the OFF-position, door interlock in the ON-position. Units/type = 1 pcs.
S00601A

Screw fixing from the back side of the handle, no screws on the front, ensures double insulation.

Colour Handle Type Order number Delivery Weight


length batch /unit
[mm] [pcs] [kg]
For shaft diameter 6 mm
S00836A

Plastic handles, black and red-yellow: I-O/ON-OFF, grey: I-O.


Black 45 OHB45J6 1SCA022380R8770 100 0.12
Red-Yellow 45 OHY45J6 1SCA022380R8930 100 0.12
Black 65 OHB65J6 1SCA022380R9660 100 0.12
Red-Yellow 65 OHY65J6 1SCA022380R9820 100 0.12
Grey 65 OHG65J6 1SCA022380R9740 100 0.12
S01200A

Plastic handles, black and red-yellow: Test/I-O/ON-OFF, grey: Test/I-O.


Black 45 OHB45J6T 1SCA109870R1001 100 0.12
OH_65J_ Black 65 OHB65J6T 1SCA022399R8110 100 0.12
Red-Yellow 65 OHY65J6T 1SCA022456R9540 100 0.12
Grey 65 OHG65J6T 1SCA022456R9620 100 0.12

Extended shafts
S00050A

Units/type = 1 piece
Shaft Front Side Type Order number Delivery Weight
length operated operated batch /unit
OXP6X_ [mm] H / [mm] H / [mm] [pcs] [kg]
For OS 32...632), shaft diameter 6 mm
63 161...167 OXP6X63 1SCA111010R1001 10 0.02
90 188...194 OXP6X90 1SCA022064R1180 10 0.03
130 127...174 228...234
3)
OXP6X130 1SCA022057R0570 10 0.04
161 138...205 OXP6X1611) 1SCA022067R1760 10 0.05
210 187...254 OXP6X210 1SCA022295R6080 10 0.06
290 267...334 OXP6X290 1SCA022042R6370 10 0.08
360 337...404 OXP6X360 1SCA022042R6530 10 0.10
430 407...474 OXP6X430 1SCA022056R6030 10 0.12

For OS 100...1602), shaft diameter 6 mm


S04131
S04131

63 196...202 OXP6X63 1SCA111010R1001 10 0.02


90 223...229 OXP6X90 1SCA022064R1180 10 0.03
130 137...1744) 263...269 OXP6X130 1SCA022057R0570 10 0.04
161 138...205 OXP6X1611) 1SCA022067R1760 10 0.05
210 187...254 OXP6X210 1SCA022295R6080 10 0.06
290 267...334 OXP6X290 1SCA022042R6370 10 0.08
360 337...404 OXP6X360 1SCA022042R6530 10 0.10
OSP_ 430 407...474 OXP6X430 1SCA022056R6030 10 0.12

Fourth poles
Snap-on mounting to the left or right side of the switch.
Suitable for Number Description Type Order number Units/ Weight
3-pole of type
switches poles [pcs] [kg]
S04129

Fusible 4. poles
S04129

OS125G_...160G_, DIN-type Fusible OSP160GD 1SCA114768R1001 1 0.40


OS125G_...160G_, BS-type Fusible OSP160GB 1SCA114769R1001 1 0.40
OS100G_...160G_, N-type Switched OSP160GN 1SCA114770R1001 1 0.40
OSS_L
Terminal shrouds
Pack of single pole terminal shrouds, snap-on mounting, grey plastic, IP 3X. Transparent shrouds
available on request.
OS100G_...160G_ 3 Long type OSS160GG1L/3 1SCA114764R1001 3 0.10
OS100G_...160G_ 3 Short type OSS160GG1S/3 1SCA114766R1001 3 0.07
S04130

OS100G_...160G_ 4 Long type OSS160GG1L/4 1SCA114765R1001 4 0.12


S04130

OS100G_...160G_ 4 Short type OSS160GG1S/4 1SCA114767R1001 4 0.08

OSS_S Auxiliary contacts


Protection degree IP20. Mounting under the mechanism cover, max. 4 contact blocks. All four contacts
can be used as “Aux./Test”-contacts and 2 contacts can be used as “Test indication” contacs.
Auxiliary contact blocks can be mounted also on the left side of the switch fuse with the OEA28
module, max. 8 contact blocks.
OS32G_...160G_ 1NO OA1G10 1SCA022353R4970 10 0.03
S00261A

OS32G_...160G_ 1NC OA3G01 1SCA022456R7410 10 0.03

1)
Included as standard 3)
OS32...63GB/GF: 115...174
OA_G 2)
Side operated, 4-pole: OS 32...63: add 45 mm, 4)
OS100GJ: 113...174, OS100GB...160GB: 121...174
OS 100...160: add 35 mm

8 Ordering information | Switch fuses OS32...160 A Gamma series


Switch fuses OS32G...160G_
Dimension drawings

OS32...63G_

mm 47,5
in 1,87
17,5 E 138...205 (OXP 6x161) 45 10
0,39
0,69 5,43...8,07 1,77

57/2,24 114 ON

OFF
6 100/3,94 4,49 O
T

0,24
ON

112/4,41
OFF

O
T

100/3,94 45/1,77 A1

25
D C 14 min 0,98
M5
3/16 0,55
A B
84
ON

OFF
8 3,31
O
T

0,31
29 OS32-63GD OS32-63GB/F OS60GJ
1,14
M00287/OS32-63G_01-04 A

mm mm mm / in B1
D01 D02 D03 D04 B/F01 B/F02 B/F03 B/F04 J01 J02 J03 J04
7
0,28 A 64,5 88 111,5 135,5 64,5 88 111,5 135,5 74,5/2,93 109,5/4,31 144,5/5,69 179,5/7,07
B 120,5 120,5 120,5 120,5 108,5 108,5 108,5 108,5 118/4,65 118/4,65 118/4,65 118/4,65
C - 23,5 23,5 23,5 - 23,5 23,5 23,5 - 35/1,38 35/1,38 35/1,38
D 40 40 40 40 40 40 40 40 45,5/1,79 45,5/1,79 45,5/1,79 45,5/1,79
E 30 30 30 30 30 30 30 30 36/1,41 36/1,41 36/1,41 36/1,41
A1 45 68,5 92 111,5 45 68,5 92 111,5 51/2,01 86/3,39 121/4,76 156/6,14
B1 75 98,5 122 145,5 75 98,5 122 145,5 81/3,19 116/4,57 151/5,94 186/7,32

mm G 138...205 (OXP 6x161) A2


in 45
F E 5,43...8,07 1,77

ON
I

114

OFF
O
T

100/3,94
ON
I 112
OFF

O
4,41
T
A1
45/1,77
B2

D 14 min
M5 H C 0,35
3/16
ON

B 84
I

OFF
A
O
T

OS32-63GD OS32-63GB/F OS60GJ


8 mm mm mm / in
0,31 D11 D12 D13 D22 B/F11 B/F12 B/F13 B/F22 J11 J112 J13 J22
B1
29 A 91 114,5 138 138 91 114,5 138 138 74,5/2,93 148/5,82 183,5/7,20 179,5/8,58
1,14
A

B 120,5 120,5 120,5 120,5 108,5 108,5 108,5 108,5 118/4,65 118/4,65 118/4,65 118/4,65
C - 23,5 23,5 23,5 - 23,5 23,5 23,5
M00288/OS32-63G_11-22

- 35/1,38 35/1,38 35/1,38


7 D 60 60 60 60 60 60 60 60 7 1,5/2,81 71,5/2,81 71,5/2,81 71,5/2,81
0,28 E 30 30 30 30 30 30 30 30 36/1,41 36/1,41 36/1,41 36/1,41
F 44 44 44 67,5 44 44 44 67,5 55,5/2,19 55,5/2,19 55,5/2,19 90,5/3,56
G 74 74 74 97,5 74 74 74 97,5 91,5/3,6 91,5/3,6 91,5/3,6 126,5/4,98
A1 70 93,5 117 117 70 93,5 117 117 81,5/3,21 116,5/4,59 151,5/5,96 151,5/5,96
A2 35 35 35 58,5 35 35 35 58,5 40,5/1,59 40,5/1,59 40,5/1,59 75,5/2,97
B1 75 123,5 147 147 75 123,5 147 147 111,5/4,39 146,5/5,77 181,5/7,15 181,5/7,15
B2 50 50 50 73,5 50 50 50 73,5 70,5/2,78 70,5/2,78 70,5/2,78 105,5/4,15

OS32...63G_S
mm M5 53 E
in 3/16 2,08 26,5
1,04

57
2,24
114
100 112 100 4,49
3,94 4,41 3,94

Shaft depth A1
Min 23/0,91
Max 27/1,06
41,5
D C 36,5 65 1,63
1,44 2,56
A (OS30-63G_S_)
F (OS30_63G_S_K) B 84
3,31
8
0,31
41
1,61 OS32-63G_ mm OS60G_ mm/ in B1
M00296/OS30_63G_01_04S A

7 DS01 DS02 DS03 DS04 B/FS01 B/FS02 B/FS03 B/FS04 JS01 JS02 JS03 JS04
0,28 A 99,5 123 146,5 170 99,5 123 146,5 170 109,5/4,31 144,5/5,69 179,5/7,07 214,5/8,44
B 132,5 132,5 132,5 132,5 120,5 120,5 120,5 120,5 130/5,12 130/5,12 130/5,12 130/5,12
C - 23,5 23,5 23,5 - 23,5 23,5 23,5 - 35/1,38 35/1,38 35/1,38
D 56,5 56,5 56,5 56,5 56,5 56,5 56,5 56,5 62/2,44 62/2,44 62/2,44 62/2,44
E 30 30 30 30 30 30 30 30 36/1,41 36/1,41 36/1,41 36/1,41
F 116,5 140 163,5 187 116,5 140 163,5 187 126,5/4,98 161,5/6,36 196,5/7,74 231,5/9,11
A1 61,5 85 108,5 132 61,5 85 108,5 132 67,5/2,66 102,5/4,04 137,5/5,41 172,5/6,79
B1 91,5 115 138,5 162,5 91,5 115 138,5 162,5 37,5/1,48 72,5/2,85 107,5/4,23 142,5/5,61

Switch fuses OS32...160 A Gamma Series | Dimension drawings 9


Switch fuses OS32G...160G_
Dimension drawings

OS100...160G_
138...205 (OXP 6x161) 10

33,4 81
20
ON

95,5 53,3 45 114

OFF
O
T

17,5 8,5 7,2 38


5,5 2,5
43
A1

17,5
ON 6 C
114,5
OFF

O
T
ON

110

OFF
O

140 65
T

M5

B1
14 min
46 35
B 25
M00289/OS100-160G_01-04 A

A OS100-160GD/F OS100-160GB
mm mm
D/F01 D/F02 D/F03 D/F04 B01 B02 B03 B04 ON

84

OFF
A 76,5 111,5 146,5 181,5 76,5 111,5 146,5 181,5
O
T

B 130 130 130 130 114,5 114,5 114,5 114,5


C 100 100 100 100 118 118 118 118
A1 55 90 125 160 55 90 125 160
B1 70 105 140 175 70 105 140 175
C1 85 120 155 190 85 120 155 190 C1

33,4 138...205 (OXP 6x161) A2

81
95,5 36 20 45
ON

114

OFF
O
T

8,5 5,5 38 2,5


43
20
A1
7,2
140
6
B2
114,5
ON

C
OFF

O
T

65 ON

M5 110
OFF

O
T

14 min
71,5 35 B
B1
D OS100-160GD/F OS100-160GB
mm mm
A D/F11 D/F12 D/F13 D/F22 B11 B12 B13 B22 C2
A 113 148 183 183 113 148 183 183
M00290/OS100-160G_11-22 A

B 130 130 130 130 114,5 114,5 114,5 114,5


C 100 100 100 100 118 118 118 118
D 81 81 81 116 81 81 81 116 ON

A1 90 125 160 160 90 125 160 160


OFF

84 O

A2
T

45 45 45 80 45 45 45 80
B1 105 140 175 175 105 140 175 175
B2 52,5 52,5 52,5 87,5 52,5 52,5 52,5 87,5
C1 120 155 190 190 120 155 190 190
C2 60 60 60 95 60 60 60 95 C1

OS100...160G_S
33,4
26,5
93
95,5
88,5 20

50 114
8,5 2,5
43 53
5,5 A1

57
34
140 C
114,5

Shaft depth 110


Min 23
Max 27
M00298/OS100_160G_S01_04 A

M5 B1
B
62,5 35
A (OS100-160G_S_) OS100-160G mm 41,5
D/F01 D/F02 D/F03 D/F04 B01 B02 B03 B04
D (OS100-160G_S_K)
A 111,5 146,5 181,5 216,5 111,5 146,5 181,5 216,5
B 142 142 142 142 126,5 126,5 126,5 126,5
C 100 100 100 100 118 118 118 118 84
D 128,5 163,5 198,5 233,5 128,5 163,5 198,5 233,5
A1 71,5 106,5 141,5 176,5 71,5 106,5 141,5 176,5
B1 86,5 121,5 156,5 191,5 86,5 121,5 156,5 191,5
C1
C1 101,5 136,5 171,5 206,5 101,5 136,5 171,5 206,5

10 Dimension drawings | Switch fuses OS32...160 A Gamma Series


Switch fuses OS32G...160G_
Dimension drawings

OS100GJ_
138...205 (OXP 6x161) 45 A1 B1
53,3/2,10 33,4 10 17,5
1,31 5,35...8,07 1,77 0,39 0,69
mm 17,5 81/3,19
in 0,69 20
8,5 0,79 114 ON

110 ON

69/2,72 4,49

OFF
4,33

OFF
O
O

0,33 60/2,36
T
T

95,5 11
3,76 0,43 2,5
0,10
46
1,81 C1
25
6 0,98
220 36 0,24
8,66 1,42 125,5
ON
4,94
84 ON
OFF

172

OFF
138,5 3,31
O
O T

6,77 5,45
65
2,56

A
38
M5 1,50

M00291/OS100GJ01-04
min 14 OS100GJ
0,55 mm / in mm / in mm / in mm / in
J01 J02 J03 J04
A 76,5/3,01 111,5/4,39 146,5/5,77 181,5/7,15
46 35
1,81 1,38 104,5/4,11 A1 55/2,17 90/3,54 125/4,92 160/6,30
B1 70/2,76 105/4,13 140/5,51 175/6,89
A C1 85/3,35 120/4,72 155/6,10 190/7,48

138...205 (OXP 6x161) A2 B2


45
33,4 5,35...8,07 1,77
1,31 81/3,19
mm 114 110
ON
ON

OFF
20

OFF
O

in 8,5 60 69/2,72 4,33


O

4,49
T
T

36 0,79
95,5 0,33 1,42 2,36
3,76 11 2,5
0,43 0,10 A1 B1
46 38 C2
4,81 1,50
220 6
8,66 36 0,24 84
125,5
ON

1,42

OFF
3,31
O
T

ON 4,94
172
OFF

O
T 6,77 138,5
5,45 C1
65
2,56 OS100GJ
mm / in mm / in mm / in mm / in
A

M5 J11 J12 J13 J22


M00292/OS100GJ11-22

A 113/4,45 148/5,83 183/7,20 183/7,20


min 14 B 81/3,19 81/3,19 81/3,19 116/4,57
71,5 0,55 A1 90/3,54 125/4,92 160/6,30 160/3,15
2,81 A2 45/1,77 45/1,77 45/1,77 80/3,15
B1 105/4,13 140/5,51 175/6,89 175/6,89
B 35 104,5/4,11 B2 52,5/2,07 52,5/2,07 52,5/2,07 160/3,44
1,38 C1 120/4,72 155/6,10 190/7,48 190/7,48
A C2 60/2,36 60/2,36 60/2,36 95/3,74

The measurements in the dimension drawings are preliminary and may be altered.

OS100GJ_S
33,4 93 26,5 34
3,66 1,04 1,34
1,31
mm
in 50 2,5
20 0,10 110
95,5 88,5 0,79 1,97 114
4,33
4,49
3,76 3,48
53 11
43 2,08 0,43 B1
1,69 A1

41,5
57 220 1,63
2,24 150 8,66
100 125,5
3,94 5,91 4,94
84
172 138,5 3,31
Shaft depth 6,77 5,45
Min 23/0,91
Max 27/1,06
C1
A

M5
M00297/OS100GJS

OS100G_ mm/ in
3/16 Ø8,5
JS01 JS02 JS03 JS04
0,33
62,5 35 A 111,5/4,39 146,5/5,77 181,5/7,15 216,5/8,52
2,46 1,38 116,5 B 128,5/5,06 163,5/6,44 198,5/7,91 233,5/9,19
A (OS100GJS_) 4,59 A1 71,5/2,81 106,5/4,19 141,5/5,57 176,5/6,95
B1 86,5/3,41 121,5/4,78 156,5/6,16 191,5/7,54
C1 101,5/4,00 136,5/5,37 171,5/6,75 206,5/8,13
B (OS100GJS_K )

Switch fuses OS32...160 A Gamma Series | Dimension drawings 11


Contact us

ABB Oy The technical data and dimensions are valid at the time of

Catalogue OS10GB 10-03, 1SCC311005B0201


printing. We reserve the right to subsequent alterations.
Low Voltage Switches
P.O. Box 622
FI-65101 Vaasa, Finland
Phone: +358 10 22 11
Fax: +358 22 45708
E-Mail: firstname.surname@fi.abb.com

www.abb.com

Producted by A&V Insinöörit Oy / Tekninen viestintä, Vaasa, Finland


ELECTRICAL COMPONENTS SDN BHD
The First Choice in Energy Efficiency

ELCO CYLINDRICAL-TYPE POWER CAPACITOR 200/205 SERIES

Three-phased Cylindrical-Type Power No. Specifications


Data

Capacitor is used to correct Power Factor for 200 Series 205 Series
1 Construction Cylindrical
Motors, Low Voltage Transformers and inside 2 External Terminal Box & Casing Finishing Extruded Aluminum Casing
Industrial Switchboard. It is sometimes used 3
4
Type
Dielectric
Dry, Self-Healing
Bi-Axially Oriented Polypropylene
with blocking reactors with harmonics 5 Plate Zinc-Aluminium Alloy
presence. 6
7
Rated Voltage (UN)
Frequency (fN)
440V
50 / 60 Hz
525V

8 Connection Internal Delta


9 Temperature Category D / -25°C to +55°C
10 Relative humidity (RH) ≤ 95%
11 Capacitance Tolerance -5% / 10%
12 Dielectric Loss ≤ 0.2W / KVAR
13 Total Losses (Including Discharge Resistor) ≤ 0.5W / KVAR
14 Encapsulation/Impregnation Polyurethanic Resin Oven Cured
Flame Retardant
15 Testing Voltage Between Terminals / time 2.15 UN / 2s
16 Testing Voltage Between Terminals and Container / time 3000 V / 10s 6000 V / 10s
17 Maximum Permissible Voltage 1.10 UN - 8 Hrs In Every 24 Hrs
1.15 UN - 30 Mins In Every 24 Hrs
1.20 UN - 5 Mins
1.30 UN - 1 Min
18 Maximum Permissible Current 1.43 IN
19 Lightning Impulse Test Terminal~Container 15KV (Peak)
20 Maximum Inrush Current 200 IN
21 Discharge Resistor For 1 - 5 Kvar Internal / 3 sets of 2 x 6.3mm Double Tags
(Discharge time - 3 min to 75V) For 10 - 30 Kvar External / 3 x M8 Treaded Cu Stud
For 35 - 40 Kvar External / Internal / 3 x M10 Treaded Cu Stud
22 Screw Torque M8 ≤ 4 Nm ; M10 ≤ 10 Nm ; M12 ≤ 15Nm
23 Terminal Arrangements Nylon Insulated Top Decks with M8 / M10
Tin Coated Brass Terminals
24 Minimum Installation Clearance 50mm Between Top of Capacitor to Enclosure;
50mm between units
25 Statistical Life Expectancy > 150,000 Operating Hours
26 Standards IEC 60831-1/2
27 IP Rating IP54(With Cable Gland And Cover-SIRIM)
28 Safety Device Pressure Activated Series Interruptor
ELECTRICAL COMPONENTS SDN BHD
The First Choice in Energy Efficiency

ELCO CYLINDRICAL-TYPE POWER CAPACITOR 200/205 SERIES

Rated Frequency,fN 50Hz 60Hz


Dimension (mm) Weight
Rated Voltage,UN 440V 415V 400V 380V 240V 440V 415V 400V 380V 240V
(kg)
Product Code Capacitance (uF) QN IN QN IN QN IN QN IN QN IN QN IN QN IN QN IN QN IN QN IN OD H +/- 0.1
200QELCO0010 3 x 5.48 1.0 1.3 0.9 1.2 0.8 1.2 0.7 1.1 0.3 0.7 1.2 1.6 1.1 1.5 1.0 1.4 0.9 1.4 0.4 0.9 60 150 0.5
200QELCO0015 3 x 8.22 1.5 2.0 1.3 1.9 1.2 1.8 1.1 1.7 0.4 1.1 1.8 2.4 1.6 2.2 1.5 2.1 1.3 2.0 0.5 1.3 60 150 0.5
200QELCO0020 3 x 10.96 2.0 2.6 1.8 2.5 1.7 2.4 1.5 2.3 0.6 1.4 2.4 3.1 2.1 3.0 2.0 2.9 1.8 2.7 0.7 1.7 60 150 0.5
200QELCO0025 3 x 13.70 2.5 3.3 2.2 3.1 2.1 3.0 1.9 2.8 0.7 1.8 3.0 3.9 2.7 3.7 2.5 3.6 2.2 3.4 0.9 2.1 60 150 0.5
200QELCO0030 3 x 16.44 3.0 3.9 2.7 3.7 2.5 3.6 2.2 3.4 0.9 2.1 3.6 4.7 3.2 4.5 3.0 4.3 2.7 4.1 1.1 2.6 60 150 0.5
200QELCO0033 3 x 18.09 3.3 4.3 2.9 4.1 2.7 3.9 2.5 3.7 1.0 2.4 4.0 5.2 3.5 4.9 3.3 4.7 3.0 4.5 1.2 2.8 60 150 0.5
200QELCO0050 3 x 27.40 5.0 6.6 4.4 6.2 4.1 6.0 3.7 5.7 1.5 3.6 6.0 7.9 5.3 7.4 5.0 7.2 4.5 6.8 1.8 4.3 65 200 0.8
200QELCO0100 3 x 54.81 10.0 13.1 8.9 12.4 8.3 11.9 7.5 11.3 3.0 7.2 12.0 15.7 10.7 14.9 9.9 14.3 9.0 13.6 3.6 8.6 86 225 1.4
200QELCO0125 3 x 68.51 12.5 16.4 11.1 15.5 10.3 14.9 9.3 14.2 3.7 8.9 15.0 19.7 13.3 18.6 12.4 17.9 11.2 17.0 4.5 10.7 86 225 1.4
200QELCO0150 3 x 82.21 15.0 19.7 13.3 18.6 12.4 17.9 11.2 17.0 4.5 10.7 18.0 23.6 16.0 22.3 14.9 21.5 13.4 20.4 5.4 12.9 86 225 1.4
200QELCO0200 3 x 109.61 20.0 26.2 17.8 24.8 16.5 23.9 14.9 22.7 6.0 14.3 24.0 31.5 21.4 29.7 19.8 28.6 17.9 27.2 7.1 17.2 86 287 1.8
200QELCO0250 3 x 137.01 25.0 32.8 22.2 30.9 20.7 29.8 18.6 28.3 7.4 17.9 30.0 39.4 26.7 37.1 24.8 35.8 22.4 34.0 8.9 21.5 100 287 2.5
200QELCO0300 3 x 164.42 30.0 39.4 26.7 37.1 24.8 35.8 22.4 34.0 8.9 21.5 36.0 47.2 32.0 44.6 29.8 42.9 26.9 40.8 10.7 25.8 100 287 2.5
200QELCO0350 3 x 191.82 35.0 45.9 31.1 43.3 28.9 41.8 26.1 39.7 10.4 25.1 42.0 55.1 37.4 52.0 34.7 50.1 31.3 47.6 12.5 30.1 120 287 3.0
200QELCO0400 3 x 219.22 40.0 52.5 35.6 49.5 33.1 47.7 29.8 45.3 11.9 28.6 48.0 63.0 42.7 59.4 39.7 57.3 35.8 54.4 14.3 34.4 120 287 3.0

QN = kVAr ; IN = Amps

Rated Frequency,fN 50Hz 60Hz


Dimension (mm) Weight
Rated Voltage,UN 525V 500V 480V 440V 525V 500V 480V 440V (kg)
Product Code Capacitance (uF) QN IN QN IN QN IN QN IN QN IN QN IN QN IN QN IN OD H
205QELCO0010 3 x 3.85 1.0 1.1 0.9 1.0 0.8 1.0 0.7 0.9 1.2 1.3 1.1 1.3 1.0 1.2 0.8 1.1 60 150 0.5
205QELCO0015 3 x 5.77 1.5 1.6 1.4 1.6 1.3 1.5 1.1 1.4 1.8 2.0 1.6 1.9 1.5 1.8 1.3 1.7 60 150 0.5
205QELCO0020 3 x 7.70 2.0 2.2 1.8 2.1 1.7 2.0 1.4 1.8 2.4 2.6 2.2 2.5 2.0 2.4 1.7 2.2 60 150 0.5
205QELCO0025 3 x 9.62 2.5 2.7 2.3 2.6 2.1 2.5 1.8 2.3 3.0 3.3 2.7 3.1 2.5 3.0 2.1 2.8 60 150 0.5
205QELCO0030 3 x 11.55 3.0 3.3 2.7 3.1 2.5 3.0 2.1 2.8 3.6 4.0 3.3 3.8 3.0 3.6 2.5 3.3 60 150 0.5
205QELCO0033 3 x 12.70 3.3 3.6 3.0 3.5 2.8 3.3 2.3 3.0 4.0 4.4 3.6 4.1 3.3 4.0 2.8 3.6 60 150 0.5
205QELCO0050 3 x 19.25 5.0 5.5 4.5 5.2 4.2 5.0 3.5 4.6 6.0 6.6 5.4 6.3 5.0 6.0 4.2 5.5 65 200 0.8
205QELCO0100 3 x 38.50 10.0 11.0 9.1 10.5 8.4 10.1 7.0 9.2 12.0 13.2 10.9 12.6 10.0 12.1 8.4 11.1 86 225 1.4
205QELCO0125 3 x 48.12 12.5 13.7 11.3 13.1 10.4 12.6 8.8 11.5 15.0 16.5 13.6 15.7 12.5 15.1 10.5 13.8 86 225 1.4
205QELCO0150 3 x 57.74 15.0 16.5Product
13.6 15.7 12.5 15.1 10.5 13.8 18.0 19.8 16.3 18.9 15.0 18.1 12.6 16.6
Dimension 86 225 1.4
205QELCO0200 3 x 76.99 20.0 22.0 18.1 20.9 16.7 20.1 14.0 18.4 24.0 26.4 21.8 25.1 20.1 24.1 16.9 22.1 86 287 1.8
205QELCO0250 3 x 96.24 25.0 27.5 22.7 26.2 20.9 25.1 17.6 23.0 30.0 33.0 27.2 31.4 25.1 30.2 21.1 27.6 100 287 2.5
205QELCO0300 3 x 115.49 30.0 33.0 27.2 31.4 25.1 30.2 21.1 27.6 36.0 39.6 32.7 37.7 30.1 36.2 25.3 33.2 100 287 2.5
205QELCO0350 3 x 134.73 35.0 38.5 31.7 36.7 29.3 35.2 24.6 32.3 42.0 46.2 38.1 44.0 35.1 42.2 29.5 38.7 120 287 3.0
205QELCO0400 3 x 153.98 40.0 44.0 36.3 41.9 33.4 40.2 28.1 36.9 48.0 52.8 43.5 50.3 40.1 48.3 33.7 44.2 120 287 3.0

QN = kVAr ; IN = Amps

PRODUCT DIMENSION

10±1mm Height ±3mm 12±1mm OD ±1.0mm


2 x 6.3mm double tag

M10
M8 Stud

OM12

16
.6
2m ±
16 ±1mm Height ± 1mm 22.0 ±1mm
m
M8

OD ±1.0mm
31.5 ± 1.5mm

OD ±1mm
OM12

16 ±1mm Height ± 1mm 19.5 ±1mm

56 ±1.5mm

PRODUCT DIMENSION
35KVAR
to
40KVAR

1.0KVAR
to
5.0KVAR
ELECTRICAL COMPONENTS SDN BHD
The First Choice in Energy Efficiency

CAPACITOR CONTACTORS
Type CNNK 12 CNNK 20 CNNK 30 CNNK 40 CNNK 50 CNNK 60 CNNK 75
Rated operation current le Amps 18 29 44 58 72 87 108

220/240V AC-6b(Kvar) 6.7 11 20 25 29 32 38

400/440V AC-6b(Kvar) 12.5 20 30 40 50 60 75


Rated Capacitor Power
500/550V AC-6b(Kvar) 15 24 35 50 60 70 88

660/690V AC-6b(Kvar) 18 30 40 58 70 80 100

Electrical Endurance Operating-cycles 200,000 150,000 100,000

Permissible Operating Temperature °C -25 to +55

Frequency of Operation, max Cycles/Hour 240 120 100

Rated Impulse Withstand Voltage KV 8

Degree of Protection IP20

Rated insulating voltage Ui V 690 1000

Maximum gG/gL fuse main circuit A 25 35 50 80 100 160 160

Closing, VA 35 65 155 310

Consumption of electromagnet p.f. 35 0.75 0.6 0.5


in cold state with Un
AC Operated Closed,VA 35 8 12 26

p.f. 35 0.3 0.29 0.24

CNNK 30
CNNK 12 CNNK 20

CNNK 40 CNNK 50 CNNK 60 CNNK 75

Excellence through Continuous Improvements

You might also like