You are on page 1of 6

CONFINED SPACE ENTRY

• Monitor LEL, O2, CO, and H2S


Calibration Station
• Internal sample pump
◊ Pull samples up to 40’
◊ Maintain steady sample flow to sensors
SDM-6000
• Audible, visual and vibration alarms
◊ 3 Ways to communicate with workers
• Ideal for refinery applications

GX-6000
• Man down alarm
• Panic alarm
• Optional sensors for toxic gases and VOCs 6 Operating modes
Modular design — one power
source for all stations Smallest 6 gas sample draw
VOC MONITORING


Four PID sensors are available
◊ 10.0 eV
2 Interchangable smart sensor slots
Connect up to 6 cylinders
◊ 10.6 eV (low or high range)
with the SV-3 solenoid valve
◊ 11.7 eV. 4 PID options: 10.6, 10.0 & 11.7 eV lamps
• PID library of over 600 VOCs (10.6 eV lamp)
• Any combination of two PID sensors can be installed.
• Easily switch target VOC from user or recent used list PID library of over 600 VOC’s
• Benzene-specific version is available • Stand-alone station (no PC Required)
• Pre filter tube for detecting low levels of benzene. • Charge, calibrate, bump test, and alarm test
• Included software collects calibration, bump Benzene specific version
test, alarm history, and exposure date from
instruments
• Automatically power instruments on / off for
LEAK INVESTIGATION scheduled calibration
• Provides ppm detection of combustible gas • Configure GX-6000 parameters
• Leak check with changing blink / pulsing rate
◊ LED’s and alarm tones increase in

Optional Accessories
frequency as gas concentration increases
• Leak check mode displays both CO & combustible levels Benzene tube
• Audible alarm silence
tube holder
◊ Perform leak investigations without alarming residents
• Barhole mode for tracking leak migration
Hose length up to 40’

FIRE INDUSTRY
• Monitor low ppm levels of dangerous gases like
ammonia, hydrogen sulfide, and carbon monoxide Flexible probe
commonly found in methamphetamine labs
• Simultaneously monitor typical confined space hazards
like LEL combustibles, oxygen deficiency, carbon
Bundles with Authorized Distributor:
monoxide and hydrogen sulfide
instrument, carrying
• Find trace levels of flammables in arson investigation
case, & accessories
• Detect carbon monoxide leaks, air quality, or strange
odors confidently
• Man down alarm (800) 754-5165 l (510) 441-5656
www. gx6000. com
RKI Instruments, Inc. World Leader In Gas Detection & Sensor Technology
GX-6000 Specifications Sensor Technologies
Smart Sensors Standard 4 Gas
Toxics
Gases & Detectable Ranges Common Specifications LEL
Measuring Minimum Alarm Gas alarm Man-down Trouble
Monitor up to 6 gases: Alarms Gas Electrochemical
Range Display Set Points Catalytic
Low flow (ESS-03DH-XXX)
LEL, O2, H2S, CO • 2 Adjustable gas alarms per channel Catalytic (NC-6264A)
2 interchangeable "Smart Sensor" slots • Man down alarm Alarm Types
Sensor connection Standard
A1: 10% LEL Low and high 1st - self reset
— PID for VOC’s • Panic alarm
Hydrocarbons
0 - 100% LEL 1% LEL adjustable 2nd - latching
Low battery 4 gas
(CH4, std) A2: 50% LEL Circuit error Gas Range Accuracy
— IR for CH4, HC, & CO2 • 4 Alarm LED’s
Calibration range
sensor Gas Range Accuracy
Galvanic
— EC for NH3, Cl2, HCN, NO2 & SO2 • Audible and vibration alarms
Sample draw pump, flow rate > 0.45 LPM,
Ammonia (NH3) 0 - 400 ppm
slots
• Trouble alarms for low flow, sensor A1: 19.5 Vol. Sample Method Chlorine (Cl2) 0 - 10 ppm ± 10% of 0 - 100% LEL
Oxygen (O2) 0 - 40% Vol. 0.1% Vol. 40 foot hose length. Consult factory for longer lengths. ± 5% of reading or ±
connection, low battery, circuit error A2: 23.5 Vol. reading or
2% of full scale (†)
and calibration Hydrogen Cyanide (HCN) 0 - 15 ppm Hydrocarbons
± 5% of full 0 - 500 /

Leak Check
Digital LCD, autobacklite, peak bar display, auto display rotation,
6 Operating modes Electro Chemical Display and customize order of gases Nitrogen Dioxide (NO2) 0 - 20.0 ppm scale (†) (CH4) 1,000 /
• Normal standard 2,000 / ± 5% of reading or ±
A1: 25 ppm Sulfur Dioxide (SO2) 0 - 99.9 ppm
LED Flashlight Audible Alarm 5,000 ppm 2% LEL (LEL mode
• Leak Check A2: 50 ppm
95 dB at 1 foot
Carbon Monitor a wide variety of toxic gases. Smart plug and (CH4) only) (†)
• Inert • On demand light source Monoxide (CO)
0 - 500 ppm 1 ppm
TWA 25 ppm English, Spanish, French, German, Italian Japanese, Korean, play sensors are auto recognized and can be remotely
• Bar Hole Languages Portuguese, Russian
Methane is the standard configuration. Other
calibrated.
STEL 200 ppm combustible gases available.
• Snap Log
LCD Display Continuous 14 hours on Lithium-ion battery pack. Complete recharge in 3 hrs.
• Benzene Specific Mode A1: 5.0 ppm
Operation 8 hours Alkaline battery pack (3 AA size within each pack) VOC’s O2
• Auto flip display A2: 30.0 ppm
Hydrogen
• Peak bar graphs 0 - 100 ppm 0.5 ppm Operating
Sulfide (H2S) TWA 1.0 ppm Photo ionization
PID Library of more than 600 VOC’s • Adjustable auto backlight Temp. -4°F to 122°F (-20°C ~ +50℃), 0 - 95% RH non condensing
Detection (PID Lamp) Galvanic (OS-BM2)
STEL 5.0 ppm & Humidity
• 4 PID options: 10.6 (2 ranges) eV, • Customize order of gases
10.0 eV, and 11.7 eV lamps • Single gas view with large font PID Sensors 2.6” W x 7.8” H x 2” D (H200 x W68 x D52 mm)
Dimensions
• 50,000 ppb / 6,000 ppm ranges and auto sequence Benzene 0.01 ppm (0 ~ 10 ppm) 14 ounce (400g) (with lithium Ion battery pack)

10.0 Lamp
0.1 - 50 ppm No Alarms Gas Range Accuracy

7.87”
• Easily choose a target VOC Specific 0.1 ppm (10 ~ 50 ppm)
Dust and water resistant with IP 67 approval 0 - 50,000 ppb Gas Range Accuracy
Case Material

11.7 eV 10.0 eV 10.6 eV


— User defined VOC list of 30 0.01 ppm (0 ~ 10 ppm) A1: 5 ppm (exclude sample hose and probe)
300 VOC’s 0 - 100 ppm 600 VOC’s
— Recently used VOC list of last 8 LEL protection mode 0.1 ppm (10 ~ 100 ppm) A2: 10 ppm 0 - 6,000 ppm Oxygen (O2) 0 - 40% Vol. ± 0.5% O2
Explosion proof: IECEx , ATEX , TIIS , cCSAus
• Shields LEL sensor from damaging A1: 5,000 ppb Safety Design /
1 ppb: (< 5000 ppb) Explosion class :Class 1, Div. 1, Groups A, B, C, D. Ex ia IIC T4
A specific electrochemical sensor for oxygen
high hydrocarbon exposure 0 - 50,000 ppb Approvals Benzene ± 10% of

10.6 Lamp
10 ppb: (> 5,000 ppb) A2: 10,000 ppb Ga Others: CE Marking 0.1 - 50 ppm
Glove friendly buttons glow-in-the-dark Specific reading, monitoring.
600 VOC’s 2 Smart sensor slots auto recognize sensor changes
0.1 ppm: (< 600 ppm) A1: 400 ppm Library of over 600 VOC’s ± 1 digit
Intrinsically Safe 0 - 6,000 ppm User defined VOC list. Up to 30 frequently used Standard Electrochemical
1 ppm: (> 600 ppm) A2: 1,000 ppm
Interchangeable battery options • IECEx Recent VOC list for last 8 selected gases High Voltage
0 - 1,000 ppb ES-1821 ES-1827i
• Lithium-ion pack operates 14 hours IR Sensors Pump and circuit status indicators Lamp
• ATEX User & station ID selection menu CO H2S
— Complete recharge in 3 hours A1: 5,000 ppm Standard
• cCSAus 0 - 10,000 ppm 25 ppm Datalogging (interval, alarm trend, station and user ID)
A2: N/A Features Monitor low ppm VOC gases.
• Alkaline pack operates 8 hours Carbon Dioxide Snap logging - on demand data logging
(CO2) A1: 0.5% Demand zero / Auto zero
0 - 10% Vol. 0.2% BUMP and CAL expiration alarm CO2
A2: 3.0%
Weather & dust resistant Flashlight CH4
0 - 100% LEL/ A1: 10% LEL
9 Languages • IP-67
Methane (CH4)
0 - 100% Vol. 1% LEL/ N/A
IrDA communication
Infrared HC
LEL sensor protection mode
• English, Spanish, French, German, Italian, 0 - 100% LEL/ 0.5% Vol. A2: 50% LEL (DES-3311-1/-2/-3/-4)
Japanese, Korean, Portuguese, Russian Hydrocarbons
0 - 30% Vol. N/A • Rubber boot • Belt clip Gas Range Accuracy
Toxics (EC Sensors) Standard • Hand strap • Tapered nozzle
Accessories • Probe with hydrophobic & dust filter 3’ teflon lined hose Carbon Monoxide
Ammonia A1: 25 ppm Gas P/N Range Accuracy 0 - 500 ppm ± 5% of
0 - 400 ppm 0.5 ppm
• Benzene pre-filter tubes and holder (benzene versions) (CO)
(NH3) A2: 50 ppm reading
Chlorine A1: 0.5 ppm Optional


SDM-6000 calibration station
Bundles with instrument carrying case and accessories
Carbon Dioxide -4 0 - 10,000 ppm Smart Hydrogen Sulfide
0 - 100 ppm ± 2 ppm (†)
(CO2) -1 0 - 10 % Vol. (H2S)
(Cl2)
0 - 10 ppm 0.05 ppm
A2: 1.0 ppm Accessories • Flexible probes • Up to 50 foot sample hoses ± 5% of sensor
• Filter set • IrDA cable 0 - 100% LEL reading or Extra long-life CO and H2S sensors.
Hydrogen
0 - 15 ppm 0.1 ppm
A1: 5 ppm Methane (CH4) -3
0 - 100% Vol. ± 2% of full slots
Cyanide (HCN) A2: 10 ppm Warranty
Two years material (including sensors) and workmanship.
One year for PID sensors (two months for 11.7 eV PID) scale (†)
Nitrogen Dioxide A1: 3 ppm 0 - 100% LEL
0 - 20.0 ppm 0.05 ppm Hydrocarbons -2
(NO2) A2: 6 ppm
0 - 30% Vol.
Sulfur Dioxide A1: 2 ppm Specifications subject to change without notice Monitor combustible gases in inert environments. Note: (†) = Whichever is greater
0 - 99.9 ppm 0.05 ppm
(SO2) A2: 5 ppm Monitor wide range of CO2.

2.6”

www.rkiinstruments.com 800 754-5165 180213/2000


GX-6000 Specifications Sensor Technologies
Smart Sensors Standard 4 Gas
Toxics
Gases & Detectable Ranges Common Specifications LEL
Measuring Minimum Alarm Gas alarm Man-down Trouble
Monitor up to 6 gases: Alarms Gas Electrochemical
Range Display Set Points Catalytic
Low flow (ESS-03DH-XXX)
LEL, O2, H2S, CO • 2 Adjustable gas alarms per channel Catalytic (NC-6264A)
2 interchangeable "Smart Sensor" slots • Man down alarm Alarm Types
Sensor connection Standard
Low and high 1st - self reset
— PID for VOC’s • Panic alarm
Hydrocarbons
(CH4, std)
0 - 100% LEL 1% LEL
A1: 10% LEL
adjustable 2nd - latching
Low battery 4 gas
Circuit error Gas Range Accuracy
— IR for CH4, HC, & CO2 • 4 Alarm LED’s
A2: 50% LEL
Calibration range
sensor Gas Range Accuracy
Galvanic
— EC for NH3, Cl2, HCN, NO2 & SO2 • Audible and vibration alarms
Sample draw pump, flow rate > 0.45 LPM,
Ammonia (NH3) 0 - 400 ppm
slots
• Trouble alarms for low flow, sensor A1: 19.5 Vol. Sample Method Chlorine (Cl2) 0 - 10 ppm ± 10% of 0 - 100% LEL
Oxygen (O2) 0 - 40% Vol. 0.1% Vol. 40 foot hose length. Consult factory for longer lengths. ± 5% of reading or ±
connection, low battery, circuit error A2: 23.5 Vol. reading or
2% of full scale (†)
and calibration Hydrogen Cyanide (HCN) 0 - 15 ppm Hydrocarbons
± 5% of full 0 - 500 /

Leak Check
Digital LCD, autobacklite, peak bar display, auto display rotation,
6 Operating modes Electro Chemical Display and customize order of gases Nitrogen Dioxide (NO2) 0 - 20.0 ppm scale (†) (CH4) 1,000 /
• Normal A1: 25 ppm standard 2,000 / ± 5% of reading or ±
Sulfur Dioxide (SO2) 0 - 99.9 ppm 5,000 ppm
• Leak Check LED Flashlight A2: 50 ppm Audible Alarm 95 dB at 1 foot 2% LEL (LEL mode
Carbon Monoxide (CH4)
0 - 500 ppm 1 ppm Monitor a wide variety of toxic gases. Smart plug and only) (†)
• Inert • On demand light source (CO) TWA 25 ppm
English, Spanish, French, German, Italian Japanese, Korean, play sensors are auto recognized and can be remotely
• Bar Hole STEL 200 ppm Languages Portuguese, Russian
Methane is the standard configuration. Other
calibrated.
combustible gases available.
• Snap Log A1: 5.0 ppm
LCD Display Continuous 14 hours on Lithium-ion battery pack. Complete recharge in 3 hrs. VOC’s
• Benzene Specific Mode Hydrogen Sulfide
0 - 100 ppm 0.5 ppm
A2: 30.0 ppm
Operation 8 hours Alkaline battery pack (3 AA size within each pack) O2
• Auto flip display (H2S) TWA 1.0 ppm
• Peak bar graphs STEL 5.0 ppm Operating Photo ionization
PID Library of more than 600 VOC’s • Adjustable auto backlight PID Sensors Temp. -4°F to 122°F (-20°C ~ +50℃), 0 - 95% RH non condensing Detection (PID Lamp)
Galvanic (OS-BM2)
& Humidity
• 4 PID options: 10.6 eV (2 ranges), • Customize order of gases 1 ppb: (< 5000 ppb) A1: 5,000 ppb

11.7 10.0 Lamp 10.6 Lamp


0 - 50,000 ppb
10.0 eV, and 11.7 eV lamps • Single gas view with large font 10 ppb: (> 5,000 ppb) A2: 10,000 ppb 2.6” W x 7.8” H x 2” D (H200 x W68 x D52 mm)
600 VOC’s Dimensions
• 50,000 ppb / 6,000 ppm ranges and auto sequence 0 - 6,000 ppm
0.1 ppm: (< 600 ppm) A1: 400 ppm 14 ounce (400g) (with lithium Ion battery pack) Gas Range Accuracy

7.87”
1 ppm: (> 600 ppm) A2: 1,000 ppm
• Easily choose a target VOC Dust and water resistant with IP 67 approval 0 - 50,000 ppb Gas Range Accuracy

11.7 eV 10.0 eV 10.6 eV


Benzene 0.01 ppm (0 ~ 10 ppm)
— User defined VOC list of 30 0.1 - 50 ppm No Alarms Case Material (exclude sample hose and probe)
Specific 0.1 ppm (10 ~ 50 ppm) 600 VOC’s
— Recently used VOC list of last 8 LEL protection mode 0.01 ppm (0 ~ 10 ppm) A1: 5 ppm 0 - 6,000 ppm Oxygen (O2) 0 - 40% Vol. ± 0.5% O2
300 VOC’s 0 - 100 ppm Explosion proof: IECEx , ATEX , TIIS , cCSAus
• Shields LEL sensor from damaging 0.1 ppm (10 ~ 100 ppm) A2: 10 ppm Safety Design /
Explosion class :Class 1, Div. 1, Groups A, B, C, D. Ex ia IIC T4 Benzene
high hydrocarbon exposure Approvals ± 10% of A specific electrochemical sensor for oxygen
High Voltage A1: 400 ppm Ga Others: CE Marking 0.1 - 50 ppm
Glove friendly buttons glow-in-the-dark 0 - 1,000 ppm 0.1 ppm Specific reading, monitoring.
Lamp A2: 1,000 ppm 2 Smart sensor slots auto recognize sensor changes
Library of over 600 VOC’s 300 VOC’s 0 - 100 ppm ± 1 digit
IR Sensors
Intrinsically Safe User defined VOC list. Up to 30 frequently used Standard Electrochemical
Interchangeable battery options • IECEx
A1: 5,000 ppm Recent VOC list for last 8 selected gases High Voltage
0 - 10,000 ppm 25 ppm 0 - 1,000 ppb ES-1821 ES-1827i
• Lithium-ion pack operates 14 hours Carbon Dioxide A2: N/A Pump and circuit status indicators Lamp
• ATEX (CO2) A1: 0.5% User & station ID selection menu CO H2S
— Complete recharge in 3 hours 0 - 10% Vol. 0.2% Standard
• cCSAus Datalogging (interval, alarm trend, station and user ID)
A2: 3.0% Features Monitor low ppm VOC gases.
• Alkaline pack operates 8 hours Snap logging - on demand data logging
0 - 100% LEL/ A1: 10% LEL Demand zero / Auto zero
Methane (CH4)
0 - 100% Vol. 1% LEL/ N/A BUMP and CAL expiration alarm CO2
Weather & dust resistant 0 - 100% LEL/ 0.5% Vol. A2: 50% LEL Flashlight CH4
Hydrocarbons
9 Languages • IP-67
0 - 30% Vol. N/A IrDA communication
Infrared HC
LEL sensor protection mode
• English, Spanish, French, German, Italian, Toxics (EC Sensors) (DES-3311-1/-2/-3/-4)
Japanese, Korean, Portuguese, Russian Ammonia A1: 25 ppm • Rubber boot • Belt clip Gas Range Accuracy
0 - 400 ppm 0.5 ppm Standard • Hand strap • Tapered nozzle
(NH3) A2: 50 ppm
Accessories • Probe with hydrophobic & dust filter 3’ teflon lined hose Carbon Monoxide
Chlorine A1: 0.5 ppm Gas P/N Range Accuracy 0 - 500 ppm ± 5% of
0 - 10 ppm 0.05 ppm • Benzene pre-filter tubes and holder (benzene versions) (CO)
(Cl2) A2: 1.0 ppm reading
Hydrogen A1: 5 ppm Optional


SDM-6000 calibration station
Bundles with instrument carrying case and accessories
Carbon Dioxide -4 0 - 10,000 ppm Smart Hydrogen Sulfide
0 - 100 ppm ± 2 ppm (†)
0 - 15 ppm 0.1 ppm (CO2) -1 0 - 10 % Vol. (H2S)
Cyanide (HCN) A2: 10 ppm Accessories • Flexible probes • Up to 50 foot sample hoses ± 5% of sensor
• Filter set • IrDA cable 0 - 100% LEL reading or Extra long-life CO and H2S sensors.
Nitrogen Dioxide
(NO2)
0 - 20.0 ppm 0.05 ppm
A1: 3 ppm
A2: 6 ppm
Methane (CH4) -3
0 - 100% Vol. ± 2% of full slots
Two years material (including sensors) and workmanship.
Warranty One year for PID sensors (two months for 11.7 eV PID) scale (†)
Sulfur Dioxide A1: 2 ppm 0 - 100% LEL
0 - 99.9 ppm 0.05 ppm Hydrocarbons -2
(SO2) A2: 5 ppm 0 - 30% Vol.
Specifications subject to change without notice Monitor combustible gases in inert environments. Note: (†) = Whichever is greater
Monitor wide range of CO2.

2.6”

www.rkiinstruments.com 800 754-5165 180213/2000


GX-6000 Specifications Sensor Technologies
Smart Sensors Standard 4 Gas
Toxics
Gases & Detectable Ranges Common Specifications LEL
Measuring Minimum Alarm Gas alarm Man-down Trouble
Monitor up to 6 gases: Alarms Gas Electrochemical
Range Display Set Points Catalytic
Low flow (ESS-03DH-XXX)
LEL, O2, H2S, CO • 2 Adjustable gas alarms per channel Catalytic (NC-6264A)
2 interchangeable "Smart Sensor" slots • Man down alarm Alarm Types
Sensor connection Standard
A1: 10% LEL Low and high 1st - self reset
— PID for VOC’s • Panic alarm
Hydrocarbons
0 - 100% LEL 1% LEL adjustable 2nd - latching
Low battery 4 gas
(CH4, std) A2: 50% LEL Circuit error Gas Range Accuracy
— IR for CH4, HC, & CO2 • 4 Alarm LED’s
Calibration range
sensor Gas Range Accuracy
Galvanic
— EC for NH3, Cl2, HCN, NO2 & SO2 • Audible and vibration alarms
Sample draw pump, flow rate > 0.45 LPM,
Ammonia (NH3) 0 - 400 ppm
slots
• Trouble alarms for low flow, sensor A1: 19.5 Vol. Sample Method Chlorine (Cl2) 0 - 10 ppm ± 10% of 0 - 100% LEL
Oxygen (O2) 0 - 40% Vol. 0.1% Vol. 40 foot hose length. Consult factory for longer lengths. ± 5% of reading or ±
connection, low battery, circuit error A2: 23.5 Vol. reading or
2% of full scale (†)
and calibration Hydrogen Cyanide (HCN) 0 - 15 ppm Hydrocarbons
± 5% of full 0 - 500 /

Leak Check
Digital LCD, autobacklite, peak bar display, auto display rotation,
6 Operating modes Electro Chemical Display and customize order of gases Nitrogen Dioxide (NO2) 0 - 20.0 ppm scale (†) (CH4) 1,000 /
• Normal standard 2,000 / ± 5% of reading or ±
A1: 25 ppm Sulfur Dioxide (SO2) 0 - 99.9 ppm
LED Flashlight Audible Alarm 5,000 ppm 2% LEL (LEL mode
• Leak Check A2: 50 ppm
95 dB at 1 foot
Carbon Monitor a wide variety of toxic gases. Smart plug and (CH4) only) (†)
• Inert • On demand light source Monoxide (CO)
0 - 500 ppm 1 ppm
TWA 25 ppm English, Spanish, French, German, Italian Japanese, Korean, play sensors are auto recognized and can be remotely
• Bar Hole Languages Portuguese, Russian
Methane is the standard configuration. Other
calibrated.
STEL 200 ppm combustible gases available.
• Snap Log
LCD Display Continuous 14 hours on Lithium-ion battery pack. Complete recharge in 3 hrs. VOC’s
• Benzene Specific Mode A1: 5.0 ppm
Operation 8 hours Alkaline battery pack (3 AA size within each pack) O2
• Auto flip display A2: 30.0 ppm
Hydrogen
• Peak bar graphs 0 - 100 ppm 0.5 ppm Operating Photo ionization
Sulfide (H2S) TWA 1.0 ppm
PID Library of more than 600 VOC’s • Adjustable auto backlight Temp. -4°F to 122°F (-20°C ~ +50℃), 0 - 95% RH non condensing Detection (PID Lamp)
Galvanic (OS-BM2)
STEL 5.0 ppm & Humidity
• 4 PID options: 10.6 (2 ranges) eV, • Customize order of gases
10.0 eV, and 11.7 eV lamps • Single gas view with large font PID Sensors 2.6” W x 7.8” H x 2” D (H200 x W68 x D52 mm)
Dimensions
• 50,000 ppb / 6,000 ppm ranges and auto sequence Benzene 0.01 ppm (0 ~ 10 ppm) 14 ounce (400g) (with lithium Ion battery pack) Gas Range Accuracy

10.0 Lamp
0.1 - 50 ppm No Alarms

7.87”
• Easily choose a target VOC Specific 0.1 ppm (10 ~ 50 ppm)
Dust and water resistant with IP 67 approval 0 - 50,000 ppb Gas Range Accuracy

11.7 eV 10.0 eV 10.6 eV


— User defined VOC list of 30 0.01 ppm (0 ~ 10 ppm) A1: 5 ppm Case Material (exclude sample hose and probe)
300 VOC’s 0 - 100 ppm 600 VOC’s
— Recently used VOC list of last 8 LEL protection mode 0.1 ppm (10 ~ 100 ppm) A2: 10 ppm 0 - 6,000 ppm Oxygen (O2) 0 - 40% Vol. ± 0.5% O2
Explosion proof: IECEx , ATEX , TIIS , cCSAus
• Shields LEL sensor from damaging A1: 5,000 ppb Safety Design /
1 ppb: (< 5000 ppb) Explosion class :Class 1, Div. 1, Groups A, B, C, D. Ex ia IIC T4 Benzene A specific electrochemical sensor for oxygen
high hydrocarbon exposure 0 - 50,000 ppb Approvals ± 10% of

10.6 Lamp
10 ppb: (> 5,000 ppb) A2: 10,000 ppb Ga Others: CE Marking 0.1 - 50 ppm
Glove friendly buttons glow-in-the-dark Specific reading, monitoring.
600 VOC’s 2 Smart sensor slots auto recognize sensor changes
A1: 400 ppm Library of over 600 VOC’s 300 VOC’s 0 - 100 ppm ± 1 digit
0.1 ppm: (< 600 ppm)
Intrinsically Safe 0 - 6,000 ppm User defined VOC list. Up to 30 frequently used Standard Electrochemical
1 ppm: (> 600 ppm) A2: 1,000 ppm
Interchangeable battery options • IECEx Recent VOC list for last 8 selected gases High Voltage
0 - 1,000 ppb ES-1821 ES-1827i
• Lithium-ion pack operates 14 hours IR Sensors Pump and circuit status indicators Lamp
• ATEX User & station ID selection menu CO H2S
— Complete recharge in 3 hours A1: 5,000 ppm Standard
• cCSAus 0 - 10,000 ppm 25 ppm Datalogging (interval, alarm trend, station and user ID)
Carbon Dioxide A2: N/A Features Monitor low ppm VOC gases.
• Alkaline pack operates 8 hours Snap logging - on demand data logging
(CO2) A1: 0.5% Demand zero / Auto zero
0 - 10% Vol. 0.2% BUMP and CAL expiration alarm CO2
A2: 3.0%
Weather & dust resistant Flashlight CH4
0 - 100% LEL/ A1: 10% LEL
9 Languages • IP-67
Methane (CH4)
0 - 100% Vol. 1% LEL/ N/A
IrDA communication
Infrared HC
LEL sensor protection mode
• English, Spanish, French, German, Italian, 0 - 100% LEL/ 0.5% Vol. A2: 50% LEL (DES-3311-1/-2/-3/-4)
Japanese, Korean, Portuguese, Russian Hydrocarbons
0 - 30% Vol. N/A • Rubber boot • Belt clip Gas Range Accuracy
Toxics (EC Sensors) Standard • Hand strap • Tapered nozzle
Accessories • Probe with hydrophobic & dust filter 3’ teflon lined hose Carbon Monoxide
Ammonia A1: 25 ppm Gas P/N Range Accuracy 0 - 500 ppm ± 5% of
0 - 400 ppm 0.5 ppm
• Benzene pre-filter tubes and holder (benzene versions) (CO)
(NH3) A2: 50 ppm reading
Chlorine A1: 0.5 ppm Optional


SDM-6000 calibration station
Bundles with instrument carrying case and accessories
Carbon Dioxide -4 0 - 10,000 ppm Smart Hydrogen Sulfide
0 - 100 ppm ± 2 ppm (†)
(CO2) -1 0 - 10 % Vol. (H2S)
(Cl2)
0 - 10 ppm 0.05 ppm
A2: 1.0 ppm Accessories • Flexible probes • Up to 50 foot sample hoses ± 5% of sensor
• Filter set • IrDA cable 0 - 100% LEL reading or Extra long-life CO and H2S sensors.
Hydrogen
0 - 15 ppm 0.1 ppm
A1: 5 ppm Methane (CH4) -3
0 - 100% Vol. ± 2% of full slots
Cyanide (HCN) A2: 10 ppm Warranty
Two years material (including sensors) and workmanship.
One year for PID sensors (two months for 11.7 eV PID) scale (†)
Nitrogen Dioxide A1: 3 ppm 0 - 100% LEL
0 - 20.0 ppm 0.05 ppm Hydrocarbons -2
(NO2) A2: 6 ppm
0 - 30% Vol.
Sulfur Dioxide A1: 2 ppm Specifications subject to change without notice Monitor combustible gases in inert environments. Note: (†) = Whichever is greater
0 - 99.9 ppm 0.05 ppm
(SO2) A2: 5 ppm Monitor wide range of CO2.

2.6”

www.rkiinstruments.com 800 754-5165 180213/2000


CONFINED SPACE ENTRY
• Monitor LEL, O2, CO, and H2S
Calibration Station
• Internal sample pump
◊ Pull samples up to 40’
◊ Maintain steady sample flow to sensors
SDM-6000
• Audible, visual and vibration alarms
◊ 3 Ways to communicate with workers
• Ideal for refinery applications

GX-6000
• Man down alarm
• Panic alarm
• Optional sensors for toxic gases and VOCs 6 Operating modes
Modular design — one power
source for all stations Smallest 6 gas sample draw
VOC MONITORING


Four PID sensors are available
◊ 10.0 eV
2 Interchangable smart sensor slots
Connect up to 6 cylinders
◊ 10.6 eV (low or high range)
with the SV-3 solenoid valve
◊ 11.7 eV. 4 PID options: 10.6, 10.0 & 11.7 eV lamps
• PID library of over 600 VOCs (10.6 eV lamp)
• Any combination of two PID sensors can be installed.
• Easily switch target VOC from user or recent used list PID library of over 600 VOC’s
• Benzene-specific version is available • Stand-alone station (no PC Required)
• Pre filter tube for detecting low levels of benzene. • Charge, calibrate, bump test, and alarm test
• Included software collects calibration, bump Benzene specific version
test, alarm history, and exposure date from
instruments
• Automatically power instruments on / off for
LEAK INVESTIGATION scheduled calibration
• Provides ppm detection of combustible gas • Configure GX-6000 parameters
• Leak check with changing blink / pulsing rate
◊ LED’s and alarm tones increase in

Optional Accessories
frequency as gas concentration increases
• Leak check mode displays both CO & combustible levels Benzene tube
• Audible alarm silence
tube holder
◊ Perform leak investigations without alarming residents
• Barhole mode for tracking leak migration
Hose length up to 40’

FIRE INDUSTRY
• Monitor low ppm levels of dangerous gases like
ammonia, hydrogen sulfide, and carbon monoxide Flexible probe
commonly found in methamphetamine labs
• Simultaneously monitor typical confined space hazards
like LEL combustibles, oxygen deficiency, carbon
Bundles with Authorized Distributor:
monoxide and hydrogen sulfide
instrument, carrying
• Find trace levels of flammables in arson investigation
case, & accessories
• Detect carbon monoxide leaks, air quality, or strange
odors confidently
• Man down alarm (800) 754-5165 l (510) 441-5656
www. gx6000. com
RKI Instruments, Inc. World Leader In Gas Detection & Sensor Technology
CONFINED SPACE ENTRY
• Monitor LEL, O2, CO, and H2S
Calibration Station
• Internal sample pump
◊ Pull samples up to 40’
◊ Maintain steady sample flow to sensors
SDM-6000
• Audible, visual and vibration alarms
◊ 3 Ways to communicate with workers
• Ideal for refinery applications

GX-6000
• Man down alarm
• Panic alarm
• Optional sensors for toxic gases and VOCs 6 Operating modes
Modular design — one power
source for all stations Smallest 6 gas sample draw
VOC MONITORING


Four PID sensors are available
◊ 10.0 eV
2 Interchangable smart sensor slots
Connect up to 6 cylinders
◊ 10.6 eV (low or high range)
with the SV-3 solenoid valve
◊ 11.7 eV. 4 PID options: 10.6, 10.0 & 11.7 eV lamps
• PID library of over 600 VOCs (10.6 eV lamp)
• Any combination of two PID sensors can be installed.
• Easily switch target VOC from user or recent used list PID library of over 600 VOC’s
• Benzene-specific version is available • Stand-alone station (no PC Required)
• Pre filter tube for detecting low levels of benzene. • Charge, calibrate, bump test, and alarm test
• Included software collects calibration, bump Benzene specific version
test, alarm history, and exposure date from
instruments
• Automatically power instruments on / off for
LEAK INVESTIGATION scheduled calibration
• Provides ppm detection of combustible gas • Configure GX-6000 parameters
• Leak check with changing blink / pulsing rate
◊ LED’s and alarm tones increase in

Optional Accessories
frequency as gas concentration increases
• Leak check mode displays both CO & combustible levels Benzene tube
• Audible alarm silence
tube holder
◊ Perform leak investigations without alarming residents
• Barhole mode for tracking leak migration
Hose length up to 40’

FIRE INDUSTRY
• Monitor low ppm levels of dangerous gases like
ammonia, hydrogen sulfide, and carbon monoxide Flexible probe
commonly found in methamphetamine labs
• Simultaneously monitor typical confined space hazards
like LEL combustibles, oxygen deficiency, carbon
Bundles with Authorized Distributor:
monoxide and hydrogen sulfide
instrument, carrying
• Find trace levels of flammables in arson investigation
case, & accessories
• Detect carbon monoxide leaks, air quality, or strange
odors confidently
• Man down alarm (800) 754-5165 l (510) 441-5656
www. gx6000. com
RKI Instruments, Inc. World Leader In Gas Detection & Sensor Technology

You might also like