Technical data: ZL2 22kW K 500

Reference conditions
Absolute inlet pressure 1 bar(a)
Relative humidity 0%
Air inlet temperature 20 °C
Cooling air inlet temperature 20 °C

Performance data*1
Maximum working pressure 550 mbar(g)
 Inlet flow 1156.4 m³/h
 Total electrical power input 26.5 kW
 Discharge temperature 88.6 °C
Effective working pressure 500 mbar(g)
 Inlet flow 1162.2 m³/h
 Total electrical power input 24 kW
 Discharge temperature 83.2 °C
Minimum effective working pressure 300 mbar(g)
 Inlet flow 1190.1 m³/h
 Total electrical power input 15.2 kW
 Discharge temperature 62 °C

Unit data*3
Mean sound pressure level*2 75 dB(A)
Anchors 4x Upat EXA 12/15 L105 mm
Oil capacity 0.7 l
Length 1253 mm
Width 1069 mm
Height 1435 mm
Net weight 571 kg

Limitations
Maximum effective working pressure 550 mbar(g)
Minimum effective working pressure 300 mbar(g)
Maximum ambient temperature 50 °C
Minimum ambient temperature -10 °C
Maximum cooling air temperature 50 °C
Minimum cooling air temperature -10 °C
Maximum altitude (above sea level) 1000 m
Installation connections
Compressed air outlet DN100
Electrical cable entry size 1x M50x1.5

Main drive motor


Motor manufacturer SIEMENS
Motor nominal power 22 kW
Motor service factor 1.2
Motor efficiency class Nema Premium
Motor full load efficiency 91.7 %
Motor protection class IP55
Motor synchronous speed
Insulation class F/B
Power factor 0.9
Motor winding protection 3xPTC
Motor bearing protection -

Electrical data
Supply voltage 460 V
Supply frequency 60 Hz
Starter type YD
Starting current DOL
Starting current YD NaN A

Main feeder circuit protection


(Customer’s installation) *6
Main fuse type RK5
Maximum main fuse size 60

Approvals
Electrical approval UL/cUL
Pressure vessel approval No

Notes
*1 The Inlet Flow figures quoted correspond to 'Actual Volume Flow Rate' in accordance with ISO 1217
Ed. 4 (2009), guaranteed with a tolerance of +/-5 % for FAD < 250 l/s (530 cfm) or +/-4 % for FAD >
250 l/s (530 cfm).
Inlet Flow is measured at the above stated reference conditions.
The Inlet Flow figures are valid for supply voltage 400V (for 50Hz-units) or 460V (for 60Hz-units).
Data may differ 0,5% maximum at other supply voltages < 1kV and 3,5% maximum at supply voltages
> 1kV
*1 The SER figures quoted are in accordance with ISO 1217 Ed. 4 (2009),
guaranteed with a tolerance of +/-6 % for FAD < 250 l/s (530 cfm) or +/-5 % for FAD > 250 l/s (530
cfm).
The SER figures are valid for supply voltage 400V (for 50Hz-units) or 460V (for 60Hz-units).
Data may differ 0,5% maximum at other supply voltages < 1kV and 3,5% maximum at supply voltages
> 1kV

*2 A-weighted emission sound pressure level at the work station (LpWSAd).


Measured according to ISO 2151: 2008 using ISO 9614-2 (sound intensity scanning method).
The added correction factor (+/- 3 dB(A)) is the total uncertainty value (KpAd) conform with the test
code.
For air cooled machines, sound pressure levels are stated with ducting of outlet cooling air according
the installation proposal

*3 Unit data is valid at reference conditions

The information in this document is subject to change without prior notice.

Publication date: <<AC:publicationDate>>