Professional Documents
Culture Documents
Reference conditions
Absolute inlet pressure 1 bar(a)
Relative humidity 0%
Air inlet temperature 20 °C
Cooling air inlet temperature 20 °C
Performance data*1
Maximum working pressure 550 mbar(g)
Inlet flow 1156.4 m³/h
Total electrical power input 26.5 kW
Discharge temperature 88.6 °C
Effective working pressure 500 mbar(g)
Inlet flow 1162.2 m³/h
Total electrical power input 24 kW
Discharge temperature 83.2 °C
Minimum effective working pressure 300 mbar(g)
Inlet flow 1190.1 m³/h
Total electrical power input 15.2 kW
Discharge temperature 62 °C
Unit data*3
Mean sound pressure level*2 75 dB(A)
Anchors 4x Upat EXA 12/15 L105 mm
Oil capacity 0.7 l
Length 1253 mm
Width 1069 mm
Height 1435 mm
Net weight 571 kg
Limitations
Maximum effective working pressure 550 mbar(g)
Minimum effective working pressure 300 mbar(g)
Maximum ambient temperature 50 °C
Minimum ambient temperature -10 °C
Maximum cooling air temperature 50 °C
Minimum cooling air temperature -10 °C
Maximum altitude (above sea level) 1000 m
Installation connections
Compressed air outlet DN100
Electrical cable entry size 1x M50x1.5
Electrical data
Supply voltage 460 V
Supply frequency 60 Hz
Starter type YD
Starting current DOL
Starting current YD NaN A
Approvals
Electrical approval UL/cUL
Pressure vessel approval No
Notes
*1 The Inlet Flow figures quoted correspond to 'Actual Volume Flow Rate' in accordance with ISO 1217
Ed. 4 (2009), guaranteed with a tolerance of +/-5 % for FAD < 250 l/s (530 cfm) or +/-4 % for FAD >
250 l/s (530 cfm).
Inlet Flow is measured at the above stated reference conditions.
The Inlet Flow figures are valid for supply voltage 400V (for 50Hz-units) or 460V (for 60Hz-units).
Data may differ 0,5% maximum at other supply voltages < 1kV and 3,5% maximum at supply voltages
> 1kV
*1 The SER figures quoted are in accordance with ISO 1217 Ed. 4 (2009),
guaranteed with a tolerance of +/-6 % for FAD < 250 l/s (530 cfm) or +/-5 % for FAD > 250 l/s (530
cfm).
The SER figures are valid for supply voltage 400V (for 50Hz-units) or 460V (for 60Hz-units).
Data may differ 0,5% maximum at other supply voltages < 1kV and 3,5% maximum at supply voltages
> 1kV