You are on page 1of 1

RAMACHAL NDT SERVICES

SHAMDEV YADAV CHAWL, NALPADA, KAPURBAWDI, THANE WEST, MAHARASHTRA. PIN - 400607
E mail: gaud8691899258@gmail.com, Contact no: 07977481791

LIQUID PENETRANT INSPECTION REPORT


Report No: Date: Sht__1__ of __1__
Client: Location:
Item Description: Surface Condition :
Reference Std: ASTM E-165, ASME Section V, Article 6
CONSUMABLES
Penetrant Penetrant Remover(Cleaner) Developer
Brand: Brand: Brand:
Lot No: Lot No: Lot No:

Expiry Date: Expiry Date: Expiry Date:


Type: Solvent Removable Type: Solvent Type: Non Aqueous wet
Application: Spraying Application: Spraying
Application: Spraying
Method: Visible Color: White
Dwell Time : _15_ Mins Dry Time : _5_ Mins Developing Time : _15_ Mins
Temperature of Part Surface : Between 25°C TO 35°C / Light Intensity: Minimum 1000 Lux / Day Light
INSPECTION RESULT
Sr. Record of Indication
Description Evaluation Tested
No Type Location Size

Following Indications shall not be Acceptable: (ASME Section VIII, Div.1, Apx.8)
1. Relevant linear Indications.
2. Relevant Rounded Indications larger than 5 mm.
3. Four or more Rounded Indication in a line separated by 1.5mm or less edge to edge.
NSD - No Significant Defect
Remarks If Any: No discontinuity found at the time of inspection, thus accepted to codes mentioned above.
Inspected By Witnessed By Reviewed By
Name: Vijay Gaud (ASNT LEVEL-2) Name: Name:
Date : Date: Date:

Sign: Sign: Sign: